Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted | |
| 2 | L2₹20.0 L+₹79,975 (4.17%)Rejected-AOC | L2 | Rejected-AOC Not accepted | |
| 3 | L3₹20.1 L+₹87,168.50 (4.54%)Rejected-AOC | L3 | Rejected-AOC Not accepted | |
| 4 | L4₹20.2 L+₹97,481 (5.08%)Rejected-AOC | L4 | Rejected-AOC Not accepted |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
5 Mar 2020, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
PROVN OF SEPTIC TANK WITH TWO SOAKAGE WELLS FOR 100 PERS, SEWAGE LINE NEAR BLDG NO P 201, ONE TOILET NEAR MAIN GATE AND MAINT OF DAD RESIDENTIAL COMPLEX GUEST HOUSE AT MIL STN DHRANGADHRA
2020_MES_322164_1
GE(A)/GNR/TOKEN/66 of 2019-20
Open Tender
Civil Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹37,000
Yes
7 Oct 2020
8 Feb 2020
7 Mar 2020
8 Feb 2020
5 Mar 2020
20 Feb 2020
8 Feb 2020 - 19 Feb 2020
Amount
Excavation over areas, and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavation over areas, and not exceeding 1.5m in depth and getting out in hard rock complete all as specified and directed.
Excavation over areas, and exceeding 1.5m but not exc 3.0m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in Hard rock complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but n.exc. 3.0m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in Hard rock complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note: Depth after punning shall be measured and paid.
Removing excavated material (soil), not exceeding 50m and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for loose filling with broken brick aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed.
M&L for hard core of gauge not exc. 63mm deposited spread and levelled in layers not exc. 15 cm thick, spread, levelled and rammed to a true surface including watering complete all as specified and directed.
M&L for for moorum/red bajri filling floors or pavings, laid in layers not exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1, using 20 mm graded stone aggregate as in surface channels and drains, benching, haunching of manholes including forms, moulds, roof paddint etc. complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for bed block/padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed.
M&L pre-cast reinforced cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in kitchen platform, shelves , cover and simillar articles including placing the cover in position and set in cement mortar (1:4) complete all as specified and directed. Note: Reinforcement shall be measured and paid seperately.
M&L for RCC M-25 ( Design Mix ) ( using 20mm graded stone aggregate ) as in suspended slabs supported on walls/columns, in floors, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for water proofing treatment to existing non-accessible roof slabs by providing 10mm thick bedding layer of cement morter (1:3) mixed with water proofing compound as per manufacturer's instruction and applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.30 Ltr/Sqm and laying of actetic polypropylene (APP) modified membrane pre-fabricated, reinforced with non-woven polyester of 3.50Kg/Sqm (minimum), 3mm thick (minimum), with minimum 75mm side overlaps and 100mm end overlaps and applying one coat of bituminous aluminium paint over APP membrane complete including taking down existing water proofing treatment with bedding layer of cement mortar complete and removal of debries out side MD land all as specified and as directed. Note:- Supply only water proofing compound shall be measured and paid separately.
Supply only, integral water proofing compound.
M&L for Brick work with old size, sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for Brick work with old size, sub class 'B' bricks, in one birck thick in honeycumb walling built in cement mortar 1:4 complete all as specified and directed.
Supply and laying sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed.
M&L for walling of random rubble stone masonry, uncoarsed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for walling of random rubble stone masonry, brought up to courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto course with maximum depression on face from straight edge held against the dressed surface not.exc. 20mm for sand stone complete all as specified and directed.
M&L for form work to soffit of suspended slabs such as roof slabs, floor slabs, landings and simillar works not exceeding 20cm thick and rough finished surfaces of concrete all as specified and directed.
S&F, 30mm thick flush shutters, solid core construction, with block board core and plywood face panles, commercial type on both sides complete all as specified and directed.
S&F,aluminium anodised, barrel tower bolts of extruded section with length of bolt 200 mm and fixed complete all as specified and directed
S&F, aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed.
S&F, butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
S&F, extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for MS rolled sections (Fe 410-W (Gde-E-250) quality-A) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
M&L for rolled mild steel angle iron work as in door frames complete, drilled for fixing of hinges etc. also fastening and fixing conforming to Fe-410-W (Gde-E-250), quality 'A' complete all as specified and directed.
S&F, mild steel work in tubular trusses, posts, main and cross beams, hip and jack rafters, purlins, including special shaped washer etc. complete using ERW or induction butt welded tubes, conforming to IS 1161-1979, Gde St-240 complete all as specified and directed.
S&F, factory made steel ventilators with top hung shutter including hinges, steel peg stay, glazing bars including applying one shop coat of red oxide primer all as specified and directed
S&F, in repairs, 2mm thick, Fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
S&F, pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F, 5mm tihck acrelic transparent sheet on existing mild steel frame work with suitable fixing arrangement complete all as specified and directed.
M&L for writting letter in english language with stainless steel of size 200mm x 100mm x 50mm wide and thickness of word is to be 5mm including fixing on acrelic sheet complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick cement concrete (1:2:4), type B-2 (using 40mm graded stone aggregate) as in hard standing, laid in alternate bays and finished surfaces even and smooth using extra cement complete all as specified and directed .
M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/hard standing, path and finishing the surface even and fair without using extra cement complete all as specified and directed.
M&L for Coloured glazed ceramic tiles of size 300 x 200 x 7mm thick, on vertical wall surface, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L, Non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in CM 1:6 complete as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on stone masonary walls/ floors surfaces mixed with using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, finished even and smooth without using extra cement to receive WPT complete all as specified and directed. Note:- Supply only water proofing compound shall be measured and paid separately.
M&L for rendering 15mm thick in cement mortar (1:4) on brick masonary walls/ floors surfaces mixed with using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, finished even and smooth without using extra cement to receive WPT complete all as specified and directed. Note:- Supply only water proofing compound shall be measured and paid separately.
M&L for rendering 20mm thick in cement mortar 1:4 and finishing coat 10mm thick in cement mortar 1:4 on stone masonry surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coat of cement base paint over a coat of white cmement putty complete all as specified and directed.
M&L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over existing shop coat of primer complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
S&F, 40mm dia High density poythelyne (HDPE) pipes of pressure rating 6kgf/sqm fixed to wall ceiling or laid in floors etc complete all as specified and directed
Supply, hoisting, fixing in position and connecting,500 litres capacity rotational moulded polyethylene water storage tank double layered (cylindrical, vertical with closed top), ISI marked, including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size and 20mm dia PTMT ball valve all as specified in SSR Part-I complete all as specified and directed.
Supplying, hoisting, fixing in position and connecting, in repairs, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed.
S&F, bib taps, cast copper alloy, fancy type, chromium plated, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
S&F, pillar taps cast copper alloy with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore complete all as specified and directed.
S&F, stop valves, fancy type, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 15mm bore complete all as specified and directed.
S&F, in repair, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight -210 Gms)
S&F, waste coupling of PTMT (half or full threaded) minimum weight 45gms of 32mm bore of discharge pipe suitable for urinals complete all as specified and directed.
S&F, only PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F, 75mm bore PVC (SWR) bend, any radius, with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) bend, any radius, with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) branch piece, single(Single Y) equal or unequal with access door complete all as specified and directed.
S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR), vent cowl complete all as specified and directed.
S&F, PVC (SWR) floor trap, with chromium plated grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 150mm bore of pipe complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 200mm bore of pipe complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in bed to drain pipes including packing under and hunching against the sides of pipe after they are laid and tested for 250mm bore of pipe complete all as specified and directed.
M&L for salt glazed stoneware drain pipes, 150mm internal diameter, grade 'A' laid in trenches and jointed complete all as specified and directed.
M&L for salt glazed stoneware drain pipes, 200mm internal diameter, grade 'A' laid in trenches and jointed complete all as specified and directed.
S&F, for 250mm bore reinforced concrete pipe class NP3, laid and jointed complete with collars all as specified and directed.
Cutting into existing manholes for connecting new drain pipes, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cment concrete (1:2:4) type B1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for 150mm bore of pipe complete all as specified and directed.
Cutting into existing manholes for cnnecting new drain pipes, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cment concrete (1:2:4) type B1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for 200/225mm bore of pipe complete all as specified and directed.
S&F, vitreous china wash basin, white, flat back of size 550mm x 400mm including brackets grouted in cement mortar 1:2 in wall complete all as specified and directed. Note :- Supply only pillar taps, waste fittings, PVC connection, PVC waste pipe shall be measured and paid separately.
S&F, vitreous china squattinbg pan, 'Orissa' pattern of size 580mm x 440mm with integral foot rest (excluding flushing cistern and flush pipe) including joining, filling and provision of cement concrete bedding 1:5:10, type E2, using 20mm graded aggregate complete all as specified and directed.
S&F vitreous china bowl urinal flat back, of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing flush pipe grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S&F, 10 litres capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets and connection to pipe or lever etc. complete all as specified and directed.
S&F, 32mm dia High density poythelyne (HDPE) pipes of pressure rating 6kgf/sqm as in waste pipe for urinal, sink, etc
Demolition of cement concrete (un-reinforced)of any description and in any position not otherwise specifically provided for, all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for One light/fan point controlled by one switch.
S&F, lamp holder, PVC/Polycarbonate, with back plate suitable for batten fittings complete all as specified and directed
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed
S&F, in repair,1x6 watts, LED bulk head luminaires deep drawn anodised body, epoxy white powder coated, heat resistant , prisamatic glass cover with specially designed gasket, including LED 6 Watt, and connecting up with twin core twisted flexible copper cable of suitable size and testing on completion all as specified and directed. As per Cat No. BIBWP6WLED of Make:- Bajaj or equivalent make approved by GE from the make specified in Appx 'C'.
S&F, in repair/replacement, LED luminarie of 45 watts IP-66, in pressure die cast aluminium housing with epoxy powder coated, prismatic polycarbonate cover with and including individual LED lenses alongwith electronic driver complete with wire and all accessaries as per make of Bajaj/Philips/CG as approved by GE from the make specified in Appx 'C'.
S&F, in repair, PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth existing pipe, fixed on pole/wall from juntion box to street light fitting complete all as specified and directed.
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, sheet metal distribution board, SPN, 4 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
Supplying & laying, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable all as specified and directed of size 16 Sqmm, 4 core of cables:-
S&F, miniature circuit breakers, SPN, 40 Amps, 240 volts, fixed in sheet metal board complete all as specified and directed.
S&F, miniature circuit breakers, SP, 6 to 32 Amps complete all as specified and directed. Make - Havells/Legrand or equivalent make as specified under Appx 'C'.
S&F, Exhaust Fan, 200mm Sweep, single phase, 230/240 volts, including making opening for exhaust fan including grouting nut, bolts and washer for fixing of fan and making good the disturbed surfaces all as per existing and mounting fan including connected with suitable three core copper conductor cable complete all as specified and directed. As per Cat No. FHVVEDXOWH08 enti Air of Havells or equivalent make as approved by GE from the make specified in Appx 'C'.
S&F, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC concealed conduit and conduit acessories including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 2.5 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: (i) 2 runs of main conductor, one run of earth conductor and one run of PVC conduit and acessories shall be measured as one unit length.(ii) Rate quoted shall deemed to includes cuttings chases for consealing PVC conduit and making good the disturbed surfaces in CM 1:3 complete.
M&L,earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m.
Singh Engineer And Contractor
Bhumi Construction
TRIMURTHI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .