Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 CrAccepted-AOC 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹40.2 Cr Quoted ₹40.3 Cr | L1 | Accepted-AOC BEING LOWEST TENDER |
| 2 | L2₹40.6 CrRejected-Finance | ₹40.6 Cr | L2 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 3 | L3₹40.9 CrRejected-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹40.9 Cr | L3 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 4 | L4₹43.0 CrRejected-Finance | ₹43.0 Cr | L4 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 5 | L5₹43.0 CrRejected-Finance 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹43.0 Cr | L5 | Rejected-Finance HIGHER THAN LOWEST TENDER |
Tender Value
₹34.5 Cr
EMD Value
₹20.5 L
Closing Date
4 Nov 2023, 6:00 pmClosed
BRIG SUSHIL KUMAR CHIEF ENGINEER
HQ CHIEF ENGINEER KOLKATA ZONE MILITARY ENGINEER SERVICES BALLYGUNGE MAIDAN CAMP GURUSADAY ROAD KOLKATA 700019
COMPLETION OF INCOMPLETE WORK FOR CONSTRUCTION OF MD ACCN AT PANAGARH PHASE I UNDER GE P PANAGARH
2023_MES_615720_1
89034/E8
Open Tender
Civil Works
540 days
PANAGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE (P) PANAGARH
₹20.5 L
Yes
30 Dec 2023
25 Aug 2023
8 Nov 2023
25 Aug 2023
4 Nov 2023
11 Oct 2023
Amount
Sch 'A' Part -I (Building Works) Note:- This Sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Completion of incomplete officer married accomodation (Block No. 01) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete officer married accomodation (Block No. 02) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete officer married accomodation (Block No. 03) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete officer married accomodation (Block No. 04) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete officer married accomodation (Block No. 05) for four Nos officer (one block of G+1) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete JCOs married accomodation (Block No. 01)for fourteen Nos JCOs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete JCOs married accomodation (Block No. 02)for fourteen Nos JCOs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.01) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.02) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.03) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.04) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Completion of incomplete ORs married accomodation (Block No.05) for fourteen Nos ROs(one block of G+3) with all fittings & fixtures etc. Complete all as specified and shown on drawings
Construction of a RCC under ground sump of capacity 1,35000.00 Ltrs with all inlet, outlet and washing outlet with necessary valves, fittings and fixture and depth 2.5 m (approx) with min free board 300mm complete all as per drawings ( JCOs & ORs Md Accn).
Construction of a RCC under ground sump of capacity 90,000.00 Ltrs with all inlet, outlet and washing outlet with necessary valves, fittings and fixture and depth 2.5 m (approx) with min free board 300mm complete all as per drawings (Offrs MD Accn).
Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATION as listed in Schedule ‘A’ Part-II on Serial Page No. 71
Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. 76(C).
Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. 78(R).
Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. 83(R).
Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. 85.
Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. 88(R).
Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. 93(R).
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. 95(R).
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-X on Serial Page No. 105(R).
Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-XI on Serial Page No.108(R).
Lumpsum price worked out by the tenderer/ bidder for RECHARGE PIT alongwith DESEILTING CHAMBERas listed in Schedule ‘A’ Part-XII on Serial Page No.113(R).
Lumpsum price worked out by the tenderer/ bidder for GARBAGE BIN as listed in Schedule ‘A’ Part-XIII on Serial Page No. 116(R).
Lumpsum price worked out by the tenderer/ bidder for DEMOLITION / DISMANTLING as listed in Schedule ‘A’ Part-XIV on Serial Page No. 117
Schedule ‘A’ Part-XVI (MISCELLANEOUS ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e 10 % Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes.
Road / Path M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) (laid in two layers of 75mm thick) with crushed stone aggragate of specified grading, spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed.
M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed. Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd.
S & F cat eye size 100 x 90x18mm of polycarbonate lens exclusively on micro onsmatic lens technology ot be fixed with screws or pasted with eposy resin based adhesive after cleaning the surface complete all as specified and directed
S & F for sparking solar road studs with body made of aluminium dia cast matt finished with anti twist ribs on the bottom anchor or size opprox 125mm x 90mm and solar battery 12V with automatic dusk to dawn solar suit all as specified and directed.
Recharge Pit S & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed.
S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed.
M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed.
External Electrification Supply, installation, testing and commissioning of step down transformer, 11000/433 Volts 200 KVA, copper wounded, oil cooled, ONAN, Vector group DYn11 suitable for outdoor installation with off load tap changer on primary side to vary output voltage upto +5% to -5% in steps of + 5.0% with all technical specifications confirming to IS 1180 (Part-I & II) as amended upto date), with minimum 02 Nos earthing all necessary standard fitting sand accessories completed with first fill of transformer oil and necessary testing after completion with the following specifications and accessories: - (01 No) (a) Standard KVA rating :- 200 KVA. (b) Neutral earthing should be solidly earth system. (c) Frequency :- 50 Hz with + 5.0% tolerance. (d) Percentage impedance : 5% at 75 deg C (subject to IS tolerance). (e) The core shall be high grade cold rolled grain oriented (CRGO) annealed steel lamination, having low loss and good grain properties, coated with “C” class grade insulation, bolted together firmly to the frames to prevent vibrations and noise. (f) The necessary LT cable and boxes as per IS 3347 and amended up to date. (g) Terminals should have necessary terminal marking plates and rating plates. (h) Necessary interconnections for LV equipments with suitable size insulated copper cable.
Design, supply, installation, testing and commissioning of compact secondary substation (CSS) comprising of following sub-systems and meeting following specifications :- (a) Sheet Steel housing with corrosion resistance and all side openable hinged door and lock and key arrangements. (b) Steel parts are tested as per IS 6988. (c) Engineer for smooth air flow for natural cooling. (d) No direct access to high voltage parts. (e) GI strip earthing for all LV and HV equipments as per laid down policy. (f) Separate earthing for lightening protection and lightening spike etc. (g) Separation steel sheet wall for RMU /Transformer / LT panel . (h) Heavy lifting lugs with all equipments load. (j) Slopped roof. (k) Necessary danger plates outside of the CSS. (l) Necessary HT/LT cable /Earth strips opening. (m) Ring Man Unit (RMU) comprising of SF-6 insulated vaccum circuit breaker (VCB) as incoming, and one metering module (CVCM) with necessary CTs and PT. (n) Transformers 315 KVA copper wounded dry rasing cast distribution type 11 KV/433V, 3 Phase, 4 wire LT output, 50 Hz, AN, DYN11, suitable for outdoor installations, with offload tap changer with steps +2.5% upto +5% on HT side with all necessary standard fittings and accessories complete after necessary testing after completion with the following specifications :- (i) Transformer standard KVA rating : 315 KVA. (ii) Primary Voltage : 11 KV AC. (iii) Secondary Voltage : 433 V AC. (iv) Neutral earthing should be solidly earth system. (v) Frequency : 50 Hz with + 3% tolerance. (vi) Vector group : Dyn11. (vii) The loses at the rated voltage should be within the specified limit as per IS-1180.
Supply, install, testing and commissioning of LT panel board outdoor type, CPRI approved, platform mounted factory made, totally enclosed dus and vermin proof openable from both front and rear side made out of 14 SWG (3 mm) thick CRCA MS Sheet and built upon suitable size angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50 Hz, 3 Phase 4 wire system and internal connection should be provided with copper strips of suitable size and necessary foundation work and comprising following. (a) Bus bar 630 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories. (b) INCOMING MCCB, 4 pole, 400 Amps, 415 volt AC, 36 KA rupturing capacity – 01 No (c) Outgoing MCCB, 4 pole, 160 Amps, 415 volt AC, 25 KA rupturing capacity – 04 Nos (d) OUTGOING MCCB, 4 pole, 63 Amps, 415 volt AC, 25 KA rupturing capacity – 01 No
Supply and install automatic power factor correction (APFC) panel outdoor type with MPP-H capacitor and MCCB as incomer, 440 Volts, 50 Hz AC of capacity 100 KVAR (50+25+15+5+2x2.5) complete all as directed.
Supply and install automatic power factor correction (APFC) panel with MPP-H capacitor and MCCB as incomer, 440 Volts, 50 Hz AC of capacity 125 KVAR (1x5.0+3x2.5+1x12.5+2x25+50) complete all as directed.
Supply and fixing LED street light fittings on poles of capacity 45 watts, high pressure die cast aluminium, IP 66 rating front cover made of toughened clear glass, suitable for pole mounting with bracket arm 40mm dia, GI light grade pipe up to 1.4 m long, bend to required shape, clamp 40mmx6mm or required length including nuts & bolts fixed on street poles complete all as specified . Make : Havells, Cat Part No –ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent in cromption
Supply and fixing solar street light with in built charger controller (PWM) 12.8V 27 Ah, charger battery/ from solar panel,m protects battery from over charging / over discharging, protects panel from reverse current including 7 meter pole with suitable fixture and LED lamp 40W complete all as directed. Make : Crompton, Cat No ; CSADSMP40CDL or equivalent in bajaj/havells/TATA BP.
Supply, laying & testing PVC insulated , PVC sheathed electric current cables (heavy duty) with stranded copper conductor of size 1.5 sqmm, 3 core, 1100 volts grade complete all as specified and as directed.
Supply and fix junction box with terminals of size 155 x 210 x 92mm or nearest higher size grade of polycarbonate body with IP 66/67 degree of protection, dust proof, water tight, shock proof fire retardant with internally embedded gasket fitted with heat treated Bakelite terminals block and PVC glands for cable entry complete all as directed.
Boring holes horizontally under road without damaging the surface of Road (minimum 1 Meter below the road surface / footbath with the help of GI Tubing not exc. 80 mm bore (dia) for passing of UG Cable, complete all as specified and as directed. Note: GI pipe laid will be measured and paid separately under appropriate item.
External Water Supply Supply and laying of pipe ductile iron, class “K-7”, 100 mm normal dia complete all as specified as directed.
Material & labour for DI specials like Bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branchy “Y” junction, double branch, cross for DI pipe upto 150 mm bore complete all as specified and as directed.
Supply and fix valves, siuice flanged of class Non-Rising 1.6 PN with SS spindle, 100 mm dia complete all as specified and as directed.
Supply and fix valves, siuice flanged of class Non-Rising 1.6 PN with SS spindle, 80 mm dia complete all as specified and as directed.
M & L construction of brick masonry chamber of 90 cm x 90 cm x 90 cm (internal dimensions) suitable for 80mm/100mm bore sluice valve with 100mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation 230mmthick brick wall with Fly ash brick, old size built in CM 1:6 PCC (1:2:4) type B1 (using 20mm graded stone aggregate for coping 50mm thick rendering in CM (1.4) 15MM thick over masonry concrete surface (Internal and External surafaces) including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as directed.
M & L construction of brick masonry chamber of 60 cm x 60 cm x 60 cm (internal dimensions) suitable for 25mm/50mm bore sluice valve with 100mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation 23mm thick brick wall with Fly ash brick, old size built in CM 1:6 PCC (1:2:4) type B1 (using 20mm graded stone aggregate for coping 50mm thick rendering in CM (1.4) 15MM thick over masonry concrete surface (Internal and External surafaces) including provision of MS sheet cover 3 mm thick with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as directed.
Drilling trail Bore of suitable diameter with reverse rotary circulation or direct circulation method or combination of both by using power rig for housing of 250 mm nominal bore reduced to 200mm below ground level in any kind of soil strata including hard stone/ boulder etc. complete all as specified and directed.
Reaming upto 525 mm upto 60 metre form ground level for insertion of casing pipe 250 mm bore.
Reaming upto 525 mm exceeding 60 metre but not exceeding 90 metre from ground level for insertion of casing pipe/ strainer 200 mm bore
Reaming upto 525 mm exceeding 90 metre but not exceeding 150 metre from ground level for insertion of casing pipe/ strainer 200 mm bore
Reaming upto 525 mm exceeding 150 metre but not exceeding 186 metre from ground level for insertion of casing pipe/ strainer 200 mm bore
Note:- (a) Depending upon the availability of water bearing strata, if drilling beyond 150 mtr is required the same shall be carried out after obtaining written approval form GE.
Supply and fixing of Ball plug having 3.00 metre length and suitable for 200 mm bore casing pipes complete all as specified and directed.
Supply, lowering and fixing in position 250 mm nominal bore ERW heavy duty MS casing pipe of 8 mm wall thickness and welding joints with MS coupler ring around the pipes with MS flat iron 50 mm x 6 mm Make:Jindal/Tata/Bansal complete as specified and directed
Supply, lowering and fixing in position 200 mm nominal bore ERW heavy duty MS casing pipe of 8 mm wall thickness and welding joints with MS coupler ring around the pipes with MS flat iron 50 mm x 6 mm Make:Jindal/Tata/Bansal complete as specified and directed
Supply, lowering and fixing in position MS reducing socket 250 mm x 200 mm nominal bore, 8 mm thick and properly welded to pipe with MS flat iron 50 mm x 6 mm coupler ring all as directed
Supply and fixing, 80mm bore galvanized steel tubing medium grade, 6.00 metre long in twin arrangements as in gravel filling arrangement to bore well fixed5 metre below ground level and 1 metre above ground level, inclined at an angle of 40 degree from horizontal plane of ground, complete all as specified and directed . Not:- PCC foundation block for the pipes will be measured and paid separately under respective items in this schedule.
Supply pouring and packing pea-gravel of size 3 mm to 8 mm and packed all around the entire bore well to fill in the annular space between pipe assembly and bore hole, complete all as specified and directed.
Material and labour for development of tube well with compressed air and after with 25% extra copacity pump by pumping muddy water complete all as specified and as directed.
Material and labour for Yield test for bore well by continuously pimping for 16 hrs to determine sate pumping yield, complete all as specified and directed.
Supply, fixing and lowering 100mm bore MS column pipe (seamless) both end flanged 3.00 metre long, fitted with flanges at both ends made out of heavy grade pipes of not less than 5.4 mm wall thickness ISI marked (IS: 1239 Part-1) complete with bolts, nuts, gaskets etc, as required complete all as specified.
Supply, fixing mild steel wire chains with dia of links 10mm, for securing submersible pump set, complete all as specified and directed.
Supply and fixing well cap made out of 5mm thick MS plate with provision of suitable holes for passing two runs of flat three core, PVC insulted industrial cable for submersible motor, 10 sq mm and suitable for fixing 250 mm nominal bore ERW heavy duty MS casing pipe of 8 mm wall thickness, complete all as specified and directed.
Supply and installed sample box for displaying samples for strata made out of teak wood plants 25 mm thick board of size (outer size of box) 1000mm x 1000mm provided with sample box (inside) of sizes 100mmx100mmx100mm complete all as specified and directed.
Electro lighting test with using suitable equipments for the bore hole before lowering of pipes and strainers for assessing proper delineation of water complete
Testing bore well raw water for all parameters, chemicals, bacteriological and arsenic aspect from any Govt approved recommended laboratory.
Material & labour for submersible cable straight through jointing kit for 10 sqmm 3 core flat cable complete all as directed
Supply and fix submersible pump set horizontal, electric driven 415V, 7.5 HP capacity at a head of 31 m for offrs Dus. Complete all as directed.
Supply and fix submersible pump set horizontal, electric driven 415V, 15 HP capacity at a head of 36 m for ORs & JCOs. Complete all as directed.
Supply & fix submersible pump set, electric driven 415 V, TP suitable for 200/250 mm dia bore well (casing pipe sixe 200/250 mm) comprising of submersible pump and motor of capacity 10 HP complete all as specified and as directed.
Supply and lowering PVC insulted sheathed 3 core flat submersible cable with copper conductor 10 Sqmm 1100 Volt grade including cable clips for fixing complete all as specified and as directed
Supply and fix automatic star delta staerter suitable for upto 15 HP submersible pump set complete all as specified and directed.
Supply and fix DOL starter with D range contractor in SS enclosure of capacity 7.5 HP capacity complete all as directed
Supply and fix non return valve both end flanged 100mm dia (CI body and brass gate heavy duty) complete with jointing material gasket, nuts, bolts, washers, all as specified.
Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the following specification:- (a) Adjustable high pressure 5Kg/Sq.cm. power input 230 V, 50 Hz, max flow rate 10 Ltr/hr with mandatory accessories like lead tubing connecting ferrules, check valves, etc (b) Preparation tank, dozing tank, consist of water inlet line, outlet with Y strainer, overflow conical bottom for sludge deposition, agitator.
(a) Supply, Installation, testing and commissioning of down flow multi grade pressure cum iron removal pressure filter having capacity 10000GPH of one vertical cylindrical mild steel pressure vessel with dished ends, vertical type with one set of 100 mm dia nominal bore frontal mild steel pipe work for inlet, outlet, back wash and drain line and 5 Nos butter fly valve having hand lever type complete – 01 No (i) the filter plant will have to ensure even distribution across the surface area of the filter bed and bottom collecting system in the arm of bed plate with strainer. (ii)The plant shall have Air release arrangement with 02 Nos pressure gauge to monitor head loss across the filter media (iii) The filter plant will have man hole, hand hole and supporting legs complete in all respects. (iv) The vessel shall be painted internally with two coats of anti-corrosive and non-toxic black bituminous paint (compatible with drinking water) and external surface shall be painted with 02 coats of synthetic paint over a (v) The plant shall be designed for a flow of 10000GPH. (vi) The iron removal filter shall have first fill of filter media as per manual. (vii) The job includes all necessary civil works such as surface dressing, PCC/RCC foundation etc as required as per manufactures instruction.
(b) Supply installation, testing and commissioning of oxidation chamber having capacity 10000GPH, consisting of one vertical cylindrical mild steel pressure vessel with dished ends, vertical type with one set of 100mm dia (medium grade) nominal bore frontal mild steel pipe work for inlet, outlet, back wash and rinse line complete – 01 No Note:- (i) The MS sheet shall be heavy grade. (ii) The plant shall be designed for a flow of 10000GPH. (iii) The vessel must be filled up with specially grade MnO2 minimum 65% purity) and hard coke catalyst media of quantity as per manufacturer instructions with supporting under bed media (iv) the vessel shall be painted internally with two coats of anti-corrosive and non-toxic black bituminous paint (compatible with drinking water) and external surface shall be painted with 02 coats of synthetic enamel paint over a coat of red oxide primer (v) The job includes all necessary civil works such as surface dressing, PCC/RCC foundation etc as required as per manufactures instruction. (c) Supply installation, testing and commissioning of Air compressor reciprocating type, horizontal model of capacity working pressure coupled with electric motor of suitable capacity 440 volts, 3 phase 50 Hz complete with Air receiver safety valve including copper cable connection from a main panel to starter and starter to motor, DOL starter panel, PCC/RCC foundation, earth work and providing 15 mm dia GI pipe medium grade form compressor to oxidation chamber including air filter etc all as specified by manufacturer – 01 No
(d) Supply installation, testing and commissioning of potassium aluminum sulphate alum pot dowzer suitable for 10000GPH filtration plant cylindrical vertical type having CI body with office system for doxing of alum solution to raw water complete all as specified and as directed – 01 No (e) Supply installation, testing and commissioning of sodium carbonate (soda pot dozer) suitable for 10000GPH filtration plant, cylindrical vertical type having CI body with office system for doxing of alum solution to raw water complete all as specified and as directed -01 No (f) Supply installation, testing and commissioning of iron testing kit with 1 ltr solution complete – 01 No (g) Supply installation, testing and commissioning of chlorine testing kit with solution complete – 01 No
Supply, installation, testing and commissioning of LT panel board outdoor type CPRI approved, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (3mm) thick CRCA MS sheet and built upon suitable size angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synthetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50 Hz, 3 Phase 4 wire system and internal connection should be provided with alluminium strips of suitable size and necessary foundation work and comprising following:- (01 No) (a) Bus bar 630 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories. (b) Incoming MCCB, 4 pole, 200 Amps, 415 Volt AC, 25 KA rupturing capacity – 01 No. (c) On lead Change over switch front operated panel mounted type 4 pole, 415 Volts AC, 160 Amps – 01 No (d) Outgoing MCCB, 3 Pole, 63 Amps, 415 Volt AC, 16 KA rupturing capacity – 03 Nos (e) Outgoing MCB SPN 32 Amps, 10 KA, “C” series, 240 Volts – 02 Nos (f) Metering and accessories – 01 No (g) Space for Starter – 03 Nos
Supply, install, testing and commissioning of LT panel board outdoor type,CPRI approved, platform mounted factory made, totally enclosed dust and vermin proof openable form both front and rear side made out of 14 SWG (3mm) thick CRCA MS Sheet and built upon suitable size angle iron frame work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts, 50 Hz, 3 Phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:- (01 No) (a) Bus bar 400 A, 50 KA breaking capacity, IP 54, 04 Nos and accessories. (b) Incoming MCCB, 4 Pole, 100 Amps, 415 volt AC, 25 KA rupturing capacity – 01 No (c) Outgoing MCCB, 3 Pole, 40 Amps, 415 Volt AC, 16 KA rupturing Capacity – 02 Nos (d)Ougoing MCB SPN 32 Amps, 10 KA, ‘C’ series, 240 volts – 02 Nos (e) Metering and accessories – 02 Nos (f) Space for Starter – 02 Nos
Supply, lowering and fixing in position 200 mm bore, low carbon galvanize (LCG) strainer 'V' wired type of 7mm thickness with 1mm continous slots to offer not less than 56% open area, bevelled end, but jointed an welded in suitable length with MS flat iron 50mm x 6mm coupler ring all around the pipe. complete all as specified and directed.
HOT WATER SUPPLY Supply, installation, commissioning & testing of storage water heater / geyser 25 Ltrs capacity 5 star rating complete with inlet and outlet pipe with all standard fittings and fixing accessories for fixing to wall including making electrical & water line connections and necessary civil work and complying with the following minimum specifications :- (158 Nos) (i) (a) Type : Vertical (b) Capacity of inner tank : 25 Ltrs (c) Colour : White (d) Temperature sensitive LED indicator (e) Feather touch digital temperature control (f) Shock proof 3 pin plug (g) Upto 8 bar pressure resistance inner tank (h) Multi functional safety valve (j) IPX4 technology to protect electrical parts from water splash (k) Earth leakage current breaker to cut off power immediately in case of current leakage and protect user from electric shocks. (l) Tank : made with ultra thick super cold rolled steel paltes dry powder coating finish and energy saving high density PUF installation. (m) Heating element : Glass coated heating element with resistant to oxidation and carbonation at high temperature of capacity 2000 W capacity. (n) Heavy duty magnesium anode rod with steel core to protect enameled tank from rust and corrison 230V, single phase, 50 Hz AC power supply 5 star energy saving rating with BEE level. Make : Havells/Cromption/Bajaj/Recold.
S & F Chromium Geyser connecting pipe complete all as directed.
S & F GI Pipe 15mm bore medium grade fixing on wall with clamp and all accessories complete all as speficed and directed
S&F 15 mm bore fancy type stop valves, cast copper alloy, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified complete all as specified and as directed.
ARBORICULTURE Cleaning of jungle, herbs, debris and dressing the area including cleaning and carting away the de bris out of site.
Making mount as per required size including supplying, dressing, compacting good earth all complete as per instruction of Engineer in Charge.
Land Preparation Trenching in ordinary soil upto a depth of 60cm including removal and stacking of un-serviceable materials and then disposing of by spreading and neatly leveling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/ and manure before and after flooding trench with water (excluding cost of imported earth , sludge or manure).
Supplying and stacking sludge/ FYM at site in dry caked from approved disposal works including royalty & all lead and lift etc. (sludge measured in stacks will be reduced by 8% for payment)
Rough dressing the trenched ground including breaking clods & Uprooting weeds from the trenched area after 12 to 15 days of its flooding with water including disposal of uprooted vegetation, Fine dressing the ground and Screeding of sludge, dump manure/ farm manure/ animal dung manure and good earth in required thickness (cost of sludge, dump manure / farm manure or/ and good earth to be paid separately)
Grassing Cynoden Dactylan (thine Leaf) : Grassing with Cynodon dactylan carpet , including watering and maintenance the area to free from weeds and maintain the area till end of the maintenance period.
Material and labour for planting and developing Plumeria rubra of 3.0 m height including following :- Digging of pits of sizes as given below in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge/ manure in the ratio 2:1 by volume (2 parts stacked volume of earth after deduction of 20% and one part of manure of stacked volume after deduction of 8%) flooding with water , dressing including removal of rubbish and surplus earth if any with all lead and lift (Note : The earth and mannure will be measured and paid for separately). The size of pits as per girth and height of tree as decided by Engr-in-Charge.
All as per item No (15.74) here in above but for Magnolia grandiflora
All as per item No (15.74) here in above but for Cassia fistula
All as per item No (15.74) here in above but for Azadirachta Indica(Neem)
All as per item No (15.74) here in above but for Alstonia Scholris(Chatim)
All as per item No (15.74) here in above but for Mimusops Elengi( Bakul)
All as per item No (15.74) here in above but for Spathodia Companulata (Flame tree)
All as per item No (15.74) here in above but for Ficus racemosa(goolar)
All as per item No (15.74) ) here in above but for Nyctanthes arbor tristis(Harshinger)
All as per item No(15.74) here in above but for Psidium Guazava
All as per item No (15.74) here in above but for Syzigium Cumini
All as per item No(15.74) here in above but for Aslbizia Lebbcca
All as per item No (15.74) here in above but for Mangifera Indica
All as per item No (15.74) here in above but for Litchi Chinensis
All as per item No (15.74) here in above Hyophorbe lagenicaulis (over all ht-8')
Supply of plants (shrubs) ht-1 ft including diging of pits as described at item No (15.74) here in above, transportation loading and un-loading & planting for Ficus starlight 2’ height
All as per item No (15.74) here in above but for Crotan (1’ height)
All as per item No (15.74) here in above but for Song of India (1’ height)
Supply of hedge / edge cropton (small/broad leaves) alternanthera, duranta, kamini (murraya exotica) 1 ft height.
Supply, Installation, testing & commissioning of crown type fountain in 3 steps with circular pool of 7 mtr dia. The fountain shall comprise of 24’ dia GI ring with 180 Nos crown nozzles, branches, sockets, stands, supports etc. Make : Glory fountain. Submersible pump at flow of 900 LPM at the head of 16 mtr, 10 HP 2.25 KW, Make : Kirloskar / Cromption / Texmo etc. Under water colour changing LED lights to highlight the Jet suitable for 12 KW 24 Nos supply with LED lights 1 mtr flexible cable all complete 12 Watt each, SMPS and controller for colour changing effect. Make : Glory fountain. 1 No Electrical 10 HP Starter Panel (outdoor type) made up of 16 gauge weather proof powder coated double door body IP-65 protection for recirclulation of pump including incoming MCB, Relay, conductor, Ammeter, Voltmeter single phase, Preventer, Push button, thimbles and wiring of Panel etc with all accessories. Make : L&T and panel make should be CPRI approved. The rate shall be included all necessary civil works i.e. necessary foundation, wall, plastering, glass bead colour tilling complete as decided by EIC.
Complete maintenance of garden features trees, shrubs, hedges/edges, lawn, seasonal flower, fountain etc like hoeing, weeding, punning, watering moving of lawn/plans, rolling of lawn, hedge, elly, upkeepers and maint of potted plants including loading, uploading carriage and displaying removal of garden rubbish spraying insecticides, pesticides, manuring if required and security of all above by employing 01 unskilled Gardener per day all as specified and directed by Engr-in-Charge. Note : The rate shall be deemed to be inclusive of following:- (i) During the period of 11 months any plant, shrubs, grass etc is found dead, not true to name or size as specified or not in satisfactory growth plant of approved size and shape shall be replaced by the contractor without any extra cost to Govt. (ii) If contractor failed to comply above, the work will be carried out through other agency and amount will be recovered from contractor. (iii) Supply and application of manure, sweet earth, sand, pesticides, fertilizers etc are included in the quoted unit rate during maintenance period.
Supply and fixing cast iron metal outdoor bench of size 1.8 m long with arm rest of seating capacity 03 seater with surface finishes as per direction of Engr-in-Charge including fixing with PCC 1:2:4 B1 type complete all as specified and directed.
Note : 1. Tree palantation – (a) Local trees to be planted shall have mix of shady trees, fruit bearing trees and ornamental trees. (b) Tree guard shall be provided for each tree. (c) Trees shall be planted along the approaches (roads) and path ways. (d) Adequate number of shady trees should be planted along the periphery. (e) Vaccant spaces towards the periphery/within te complex shall be planted with fruit bearing trees. (f) Distance between the trees shall be uniform and adequate for the trees to grow. (g) Local trees shall be planted such as Mahogany, Kadam, Shirish, Sonajhuri, Krishnachura, Radhachura, Bakul, Jarul, Gandharaj, Tagar, Palash, Mango, Jamun, Amla, Guava. 2. The plant shall include the open space between the building including park if available. 3. System for watering the plants shall be catered for. 4. In case of open space the slope of the ground shall be such that no accumulation of water takes place. 5. Landscaping and adequate furniture shall be provided for lawns & parks. 6. Hedges shall be included in open space and also around ground floor accommodation.
Internal electrification: M&L for blank plate complete all as specified and directed. Make- C & S(Model-Primo plus)/Crabtree/Legrand/Hager/Anchor
Supply and fixing single phase Air- conditionar starter switch complete all as specified and directed. Make- Havells. SAP Code AHOO002004 or equivalent model of Legrand/Hager/Anchor
Supply and fixing TV socket outlet piano flush type ISI marked with valid CML No. complete all as specified and directed.
Supply and fixing socket outlet RJ 11 for telephone, piano flush type ISI marked with valid CML No. complete all as specified and directed.
Supply and fixing surface & wall mounted LED 4 feet with 1X20 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specifications: - (i) System Watts/lumens: - Max 20 W/T (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) LED Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution
(xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 NABL acceridite lab test report conforming to technical specifications and consolidate lab test report for the offered LED has to be structured in the sequence (xvii) Make: - As per Appx 'D'
Supply and fixing surface & wall mounted LED 2 feet with 1X10 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specifications: - (i) System Watts/lumens: - Max 10 W/T (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) LED Efficacy (lm/Watt): - Not less than 120 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution
(xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design (xvi) Bidder has to compulsorily submit the LM-79 and LM-80 NABL acceridite lab test report conforming to technical specifications and consolidate lab test report for the offered LED has to be structured in the sequence (xvii) Make: - As per Appx 'D'
Supply and fix surface Wall mounting Champagne glod finish fixture with plastic body suitable for 9 Watt LED lamp B22 base including 9 W LED lamp indoor luminaries comlete all as specified and directed. Make:- Havells (Model No:LHFOECE1TZ10014) or eqivalent make as per Appx 'D'.
Supply and fix surface mounted LED mirror light 13 watt Indoor luminaries with and including electronic driver and LED lamp , pre -wired including necessary electric connection from celling rose to light fitting comlete all as specified and directed. Make: Philps (Model: Linea) or eqavalent make as per Appx 'D'.
Supply and fixing LED street light fitting 35/36 Watt 230 V AC outdoor type minium output 105 lumen/watt with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M&L for Brush Less DC (BLDC) ceiling fan with the following specifications: - (i) Motor: - Brushless DC 26 W, with operating voltage 140V-240V AC, 50 Hz. (ii) Max RPM: - 360 RPM (iii) Sweep: - 1200mm (iv) colour:- white (v) Remote control operated (vi) 5 STAR energy saving rating.
M&L for exhaust fan 250 mm sweep with polycarbonate blades flush mounting, square type body case, operated on 230V, single phase Ac, 50 Hz with connection complete all as specified and dirtected.
M&L for exhaust fan 300 mm sweep with metalic aerodynamically desinged & blanced baldes flush mounting Square type body case blades flush mounting, square type body case, operated on 230V, single phase Ac, 50 Hz with connection complete all as specified and dirtected.
M&L for Wall Mouted fan 400 mm sweep with polycarbonate blades Suitable for wall mounted operated on 230V, single phase Ac, 50 Hz with connection complete all as specified and dirtected.
S & F sheet metal enclosure for vertical Loadline DB's Tripe pole and neutral 6 way double door 415 volts when MCCB 4 pole to be used as incommer complete all as specified and directed.
M&L for MCB SPN 40A, 230V, 50 Hz, computable for DIN rail "C" series , rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB SPN 40A, 230V, 50 Hz, computable for DIN rail "C" series , rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB TPN 40 to 63A, 415V, 50 Hz, computable for DIN rail "C" series,rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB TP 40 to 63 A, 415V, 50 Hz, computable for DIN rail "C" series,rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB SP 40A, 230V, 50 Hz, computable for DIN rail "C" series rupturing capacity 10KA with connection complete all as specified and directed.
M&L for MCB SP 6 to 32A, 230V, 50 Hz, computable for DIN rail "C" series,rupturing capacity 10KA with connection complete all as specified and directed.
M&L for PVC Concealed conduit only with necessary junctionbox and accessories 20mm for TV and Telephone cable with all cutting and finishing work complete all as specified and directed.
M&L for tamper proof electronic energy meter, single phase, AC 240V, 50 Hz, with accuracy class 1.0, LED indicator , high surge withstand capacity up to 8 KV, polycarbonate enclosure, Anti tamper proof, 15-40A rating with special features like TOD,Tamper logging,optical communication port & display in absence of power with transparent hinge type box ( measure and displays kWH,V,I,kW,PF,last month history of kWH &MD in kW) and necessary sheetmetal meter box complete all as specified and directed.
M&L for tamper proof electronic energy meter, three phase, AC 3X240V, 50 Hz, with accuracy class 1.0, LED indicator , high surge withstand capacity up to 8 KV, polycarbonate enclosure, Anti tamper proof, 10-60A rating with special features like TOD,Tamper logging,optical communication port & display in absence of power with transparent hinge type box ( measure and displays kWH,V,I,kW,PF,last month history of kWH &MD in kW) and necessary sheetmetal meter box complete all as specified and directed.
surendra infrastructure pvt ltd
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED
NAND LAL PURI AND SONS PRIVATE LIMITED
VERMA BROTHERS
Ktech Engineer Builders Co. Pvt. Ltd
LUMOS INFRA PVT LTD
UNITED ROAD CONSTRUCTIONS PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid