| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-Finance | L1 | Accepted-Finance Selected | |
| 2 | L2₹5.0 L+₹1.0 L (25.0%)Accepted-Finance 50 3 S F ARJUN NAGAR NEW DELHI 110029 | SOUTH | DELHI | 110029 | L2 | Accepted-Finance Selected | |
| 3 | L3₹5.8 L+₹1.7 L (43.3%)Accepted-Finance 15 119 DAKHINPURI NEW DELHI 110062 | SOUTH | DELHI | 110062 | L3 | Accepted-Finance Selected | |
| 4 | L4₹6.0 L+₹1.9 L (48.0%)Accepted-Finance SHAHDARA | DELHI | 110095 | L4 | Accepted-Finance Selected |
Tender Value
₹7.4 L
EMD Value
₹14,790
Closing Date
1 Jun 2026, 3:00 pmClosed
The Executive Engineer (E)
The Executive Engineer (E) EMD South East, Thyagraj Stadium, New Delhi-110003
(SH- Restoration of Electrical supply for the existing electrical pole due to fire at Barapullah Flyover and Bhishma Pitamah Flyover under PWD EMD South East Division).
2026_PWD_291982_1
33/EE(E)/EMD South East/PWD/2026-27
Open Tender
Miscellaneous Services
Works
30 days
At Site
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹14,790
3 Jun 2026
25 May 2026
1 Jun 2026
25 May 2026
1 Jun 2026
25 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, THD < 10% as per IEC 61000-3-2, P.F. ≥ 0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg - 120 deg as per the application and the project requirement, suitable tiltable fitting, lifetime (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not be more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 to <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape, size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 1.01 | 150 watt | 20 | Nos. | 3,166 | ₹63,320 |
| 2 | Supplying and fixing of SMC Junction box having size 140 x 140 x 95 mm Single door, pole mounted weatherproof SMC junction box compete with terminal block suitable for 25 sq. mm conductor, DIN bar, SP MCB with suitable. M.S. clamp on the existing pole for light fixture etc as required | 20 | Nos. | 425 | ₹8,500 |
| 3Supplying and fixing of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1 KV grade of following size on wall surface as required. | |||||
| 3.01 | 3X10 Sq.mm | 250 | Mtrs. | 333 | ₹83,250 |
| 4Supplying and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. | |||||
| 4.01 | 4X25 Sq. mm. | 150 | Mtrs. | 732 | ₹1,09,800 |
| 5Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. | |||||
| 5.01 | 4X25 Sq. mm. | 100 | Mtrs. | 543 | ₹54,300 |
| 6laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
tender.pdf
Tender Documents • 2.86 MB
BOQ_387553.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .