Loading…
Loading…
Tender Value
₹96.6 L
EMD Value
₹96,568
Closing Date
12 May 2026, 6:00 pmClosed
ZALOD NAGAR PALIKA, ZALOD
BID DOCUMENTS FOR CONSTRUCTION WORK OF C.C.ROAD, COMPOUND WALL, R.C.C NP3 PIPE LINE AND LED STREET LIGHT POLE WITH ALL ACCESSORIES IN VARIOUS AREA AT ZALOD NAGARPALIKA UNDER: 15TH FINANCE SCHEME (UNTIED) GRANT.(PACKAGE:08).
300805
1/2026-27 pkg no. 08
Open
Civil Works
Dahod
14 documents required · 13 mandatory · 1 optional
₹2,832
Chief Officer, ZALOD Nagar Palika, ZALOD
₹96,568
2 May 2026
2 May 2026
2 May 2026
12 May 2026
2 May 2026
1 ESTIMATE FOR PROVIDING AND LAYING OF 300MM DIA R.C.C. NP3 PIPE DRAIN AT Rs.
PUSHPA KUNJ SOCIETY BHAG 2 AT ZALOD.
2 ESTIMATE FOR CONSTRUCTION OF COMPOUND WALL AT NEAR PETROL PUMP AT Rs.
ZALOD ( WARD 5)
3 ESTIMATE FOR PROVIDING, SUPPLYING AND INSTALLATION OF SOLAR LED STREET Rs.
LIGHT AT MUVADA RAYNA FALIYA AT ZALOD.
4 ESTIMATE FOR PROVIDING AND LAYING OF 600 MM DIA R.C.C. NP3 PIPE DRAIN FROM Rs.
BEHIND SION NAGAR SOCIETY AT ZALOD.
5 ESTIMATE FOR PROVIDING, SUPPLYING & ERECTING OF LED STREET LIGHT POLE Rs.
WITH ALL ACCESSORIES AT INDRAPRASTH SOCIETY AT ZALOD (WARD 5).
6 ESTIMATE FOR PROVIDING, SUPPLYING & ERECTING OF LED STREET LIGHT POLE Rs.
WITH ALL ACCESSORIES FROM MADRESHA TO PADI MAHUDI AT ZALOD (WARD 6).
7 ESTIMATE FOR PROVIDING, SUPPLYING & ERECTING OF LED STREET LIGHT POLE Rs.
WITH ALL ACCESSORIES FROM HANUMAN MANDIR TO BAYPASS CHOKADI AT ZALOD
8 ESTIMATE FOR PROVIDING, SUPPLYING & ERECTING OF LED STREET LIGHT POLE Rs.
WITH ALL ACCESSORIES FROM LAKHA BHAI HOUSE TO BHALABHAI HOUSE AT ZALOD
9 ESTIMATE FOR CONSTRUCTION WORK OF C. C. ROAD AT RAJUBHAI'S HOUSE TO Rs.
MAHADEV TAMPLE AT ZALOD ( WARD 6 )
I/ We agree to carry out the above Work at ___________________________________% above/below the estimated rate.
(In Words) ______________________________________Percentage above/below the estimated Rate
Estimated Amount Put to Tender Rs.
% Above / Below _____________ %
Net Amount Rs. ________________
I/ We have read the conditions mentioned in this tender and agree to abide by the same
SECTION-7 BILL OF QUANTITIES-216
Seal & Signature of Contractor
President Chief Officer
Zalod Nagarpalika
Devgadh Baria Municipality, Zalod Nagarpalika
SECTION-7 BILL OF QUANTITIES-217
ZALOD MUNICIPALITY, ZALOD
ESTIMATE FOR PROVIDING AND LAYING OF 300MM DIA R.C.C. NP3 PIPE DRAIN AT PUSHPA KUNJ SOCIETY
BHAG 1 AT ZALOD.
Sr. Qty. Total Per Amount
1 249.00 Excavation for Foundation up to 1.5M depth including sorting of
Cmt. useful materials and dispoising of the excavated stuff up to 50 meter
lead in Loose or Soft soil.
2 100.00 Excavation for Foundation1.5M to 3.0 M depth including sorting of
Cmt. useful materials and dispoising of the excavated stuff up to 50 meter
lead in Loose or Soft soil.
3 166.00 Supplying and fixing reinforced concrete heavy duty non-pressure
Rmt. pipes with collars for culverts carring heavy trafficas per IS 458-
1991Specification including setting and joining the pipes in C:M 1:2
watering and laying (to level or slopes) of I.S. class NP3 of following
internal diameters. (iii) 300mm Dia.
4 337.00 Filling Availabale Excavated Earth (excluding Rock) in trenchess
Cmt. plinth, sides of foundation etc. in layers not exceding 20 cm in depth
consolidated each deposited layer by ramming and watering
5 16.00 Construction manhole with R.C.C. top slab in 1:2:4 mix (1 cement:2
Nos. coarse sand:4 graded stone aggregate 20mm nominal size)
foundation concrete 1 : 3 : 6 mix (1 cement : 3 coarse sand :6 brick
bats 40 + 50mm size) inside plastering 15mm thick with cement
mortar 1: 5 (1: cement :5 coarse sand ) finished with a floating coat
of neat cement and making channels in cement concrete 1:2:4 mix
91: cement :2 coarse sand : 4 stone aggregate 20 mm nominal size)
finished smooth complete including curing and festing (i) inside size
900mm x 1200 mm and 1.5 M deep including C.I cover with frame
size 560 mm diameter total weight of cover and frame to be not less
than 128 Kgs. ( wt. of cover 64 Kg. and wt. of frame 64 Kg. ) ( A) with
230 mm thick walls of brick masonry using brick having crushing
strength not less than 35 Kg. / Sq.cm. in cement mortat 1:5 ( 1:
cement :5 coarse sand ) (3) A type depth 0.90 meter for 300 mm
diameter sewer. 11042.74 No.
6 10.00 Providing and laying P.C.C. (1:3:6) mix (1 cement, 3 coarse sand,
Cmt. hand broken stone aggregate of 40mm nominal size) and curing
complete excluding the cost of formwork in (A) Foundation and
Plinth. 3114.05 Cmt.
SBD SECTION-7 BILL OF QUANTITIES-218
Cmt. Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete 419.82 Cmt.
Add :- 18% of GST, Rs.
Add :- 1% of Qaulity Controll Rs.
Add :- 2% of Contingency Charges Rs.
SBD SECTION-7 BILL OF QUANTITIES-219
ZALOD MUNICIPALITY, ZALOD
ESTIMATE FOR CONSTRUCTION OF COMPOUND WALL AT NEAR PETROL PUMP AT ZALOD ( WARD
PROPOSED COMPOUND WALL AT ZALOD
Item Qty. Description Total Unit Amount
1 161.00 Excavation for foundation up to 1:5 mt. Depth
Cmt. including sorting out and stacking of useful materials
and depositing of the excavated stuff up to 50 meter
lead. 125.86 Cmt.
2 29.00 Excavation for foundation from depth 1:5 mt. to 3.0 mt.
Cmt. Depth including sorting out and stacking of useful
materials and depositing of the excavated stuff up to
50 meter lead. (a) Loose or soft soil.
3 131.00 Filing available excavated earth (excluding rock) in
Cmt. trenches plinth sides of foundations etc. in layers not
exceeding 20cm. In depth consolidating each deposited
layer by remming and watering.
4 18.00 Providing and laying cement concrete 1:4:8 (1-Cement :
Cmt. 4-fine sand : 8-graded birck aggregates 40 mm nominal
size) and curing complete excluding cost of form work in
(a) Foundation and plinth. 2684.01 Cmt.
5 29.00 Providing and Laying controlled cement concrete M-250
Cmt. and curing complete, including the cost of formwork but
excluding the cost of reinforcement for reinforced
concrete work in Column footings.
6 5.50 Providing and laying controlled cement concrete M-250
Cmt. and curing complete including the cost of formwork But
Excluding the cost of reinforcement for reinforced
concrete work in Column upto Plinth Level having any
cross section area.
7 8.00 Providing and Laying controlled cement concrete M-250
Cmt. and curing complete, including the cost of formwork but
excluding the cost of reinforcement for reinforced
concrete work in Columns having any cross section area
upto floor two level.
8 8.00 Providing and laying controlled cement concrete M-250
Cmt. and curing complete including the cost of formwork but
Excluding the cost of reinforcement for reinforced
concrete work in Ground Beam having
SBD SECTION-7 any
BILL OFcross section
9 1.50 Providing and laying controlled cement concrete M-250
Cmt. and curing complete including the cost of formwork and
excluding the cost of reinforcement of reinforced
concrete work in COPING 6374.11 Cmt.
5220.00 Providing and supplying TMT Fe-500 bar steel
Kgs. reinforcment for R.C.C work including bending, binding
and placing in position etc. complete
11 38.00 Brick work using common burnt building bricks having
Cmt. crushing strngth not less than 35 Kg./cm2 in super
structure for Ground Floor in C.M. (1:6) (1 Cement,
fine sand) racking out joints curring etc. complete
directed by Engineer-in-charge. 4295.99 Cmt.
12 273.00 20 mm thick sand faced cement plaster on walls up to
Smt heinht 10 metres above ground laval cosisting of 12 mm
thick backing coat of C:M 1:3 (1-cement :3-sand) and
8mm thick finishing coat of C:M 1:1 (1-cement :1-sand)
13 273.00 Finishing wall with water proof exterior emulsion apex
Smt paint of on wall surfaces (two coats) to give an approved
brand and manufacture and of required slope evan
shade after throughly brushing the surface to remove all
dirt and remains of loose powered materials. etc
completed. 114.53 Smt.
Add 18.00 % GST
Add 2% For Contingecies Charges Rs.
Add 1% For Quality Control Rs.
SBD SECTION-7 BILL OF QUANTITIES-221
ZALOD MUNICIPALITY, ZALOD
ESTIMATE FOR PROVIDING, SUPPLYING AND INSTALLATION OF SOLAR LED STREET LIGHT AT
MUVADA RAYNA FALIYA AT ZALOD.
Sr. Quantity Discription Total Unit Amount
1 Supplying and erecting LED Solar street lights with High
power White LEDs wattage of 1Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses with company mark/name
engraved or embossed with 36 hours battery backup &
MPPT 24V,7.5 A charge controller with 12 hours
automatic switch on/off with wind speed resistance
28.00 (E) 36W,3000 lumens, IP-65, PV Module – 2x100W and
Nos. 6 mtr poles complete erected 36154.97 No.
Add :- 18% of GST, Rs.
Add :- 1% of Qaulity Controll Rs.
Add :- 2% of Contingency Charges Rs.
SBD SECTION-7 BILL OF QUANTITIES-222
ZALOD MUNICIPALITY, ZALOD
ESTIMATE FOR PROVIDING AND LAYING OF 600 MM DIA R.C.C. NP3 PIPE DRAIN FROM BEHIND
SION NAGAR SOCIETY AT ZALOD.
Sr. Qty. Total Per Amount
1 666.00 Excavation for Foundation up to 1.5M depth including
Cmt. sorting of useful materials and dispoising of the excavated
stuff up to 50 meter lead in Loose or Soft soil.
2 267.00 Excavation for Foundation1.5M to 3.0 M depth including
Cmt. sorting of useful materials and dispoising of the excavated
stuff up to 50 meter lead in Loose or Soft soil.
3 296.00 Supplying and fixing reinforced concrete heavy duty non-
Rmt. pressure pipes with collars for culverts carring heavy
trafficas per IS 458-1991Specification including setting and
joining the pipes in C:M 1:2 watering and laying (to level or
slopes) of I.S. class NP3 of following internal diameters. (iii)
4 826.50 Filling Availabale Excavated Earth (excluding Rock) in
Cmt. trenchess plinth, sides of foundation etc. in layers not
exceding 20 cm in depth consolidated each deposited layer
by ramming and watering
5 14.00 Construction manhole with R.C.C. top slab in 1:2:4 mix (1
Nos. cement:2 coarse sand:4 graded stone aggregate 20mm
nominal size) foundation concrete 1 : 3 : 6 mix (1 cement :
coarse sand :6 brick bats 40 + 50mm size) inside plastering
15mm thick with cement mortar 1: 5 (1: cement :5 coarse
sand ) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix 91: cement
:2 coarse sand : 4 stone aggregate 20 mm nominal size)
finished smooth complete including curing and festing (i)
inside size 900mm x 1200 mm and 1.5 M deep including C.I
cover with frame size 560 mm diameter total weight of cover
and frame to be not less than 128 Kgs. ( wt. of cover 64 Kg.
and wt. of frame 64 Kg. ) ( A) with 230 mm thick walls of
brick masonry using brick having crushing strength not less
than 35 Kg. / Sq.cm. in cement mortat 1:5 ( 1: cement :5
coarse sand ) (3) A type depth 0.90 meter for 600 mm
diameter sewer.
SBD SECTION-7 BILL OF QUANTITIES-224
6 30.00 Providing and laying P.C.C. (1:3:6) mix (1 cement, 3 coarse
Cmt. sand, 6 hand broken stone aggregate of 40mm nominal
size) and curing complete excluding the cost of formwork in
(A) Foundation and Plinth.
7 30.00 Filling in plinth with sand under floors including watering
Cmt ramming, consolidating and dressing complete
Add :- 18% of GST, Rs.
Add :- 1% of Qaulity Controll Rs.
Add :- 2% of Contingency Charges Rs.
SBD SECTION-7 BILL OF QUANTITIES-225
ZALOD MUNICIPALITY, ZALOD
ESTIMATE FOR PROVIDING, SUPPLYING & ERECTING OF LED STREET LIGHT POLE WITH ALL ACCESSORIES AT
INDRAPRASTH SOCIETY AT ZALOD .
Sr. Quantity Discription Total Unit Amount
1 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured
copper cable 1.1 KV grade to be erected as directed of
following size.
328.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
2 3.00 Supplying & erecting following spare parts for panel
Ea. mounting Switch Disconnector Fuse Units. Operational
Handle Assembly Complete for (i) 32/63/125 Amps.
3 3.00 Supplying and erecting triple pole & neutral 440V / 500V
Rmt. panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each
bar, erected in existing cubical panel with necessary
connections. (A) Suitable for 100 Amp. Capacity.
4 3.00 Supplying & erecting following spare parts for panel
Ea. mounting Switch Disconnector Fuse Units. Neutral Link for
5 3.00 Supplying and erecting approved make 415V bakelite fuse
Ea. fittings for front connection / busbar type to accommodate
HRC fuse link, with spin - riveted brass contact, having
thermo plastic inflammable material & single piece
extruded brass box contact to lock with adequate cable
hole to accommodate aluminium conductors suitable for
(without HRC fuse). For 63 Amp.
6 3.00 Supplying and erecting Ammeter / Voltmeter selector
Ea. switch for 3 phase AC Supply 500 V on existing panel
board with necessary connections. 317.14 Ea.
7 3.00 Supplying and erecting approved make suitable panel
Ea. indicator LED type lamp, lens cover, complete erected with
necessary connections. 43.43 Ea.
8 3.00 Providing & erecting Spares For Air Circuit Breakers as
Ea. follows: (B) Auxiliary Contact Block for CN-CS 800 to
SBD SECTION-7 BILL OF QUANTITIES-226
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
205.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
205.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 50.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
Mtr. cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables.(e) 4 core 25 Sq. mm
12 3.00 Providing and erecting Approved make Four pole moulded
Ea. case circuit breaker having breaking capacity ICU of
KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to
work on A.C. supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing
16 G.M.S. housing. Cat.III. ICS=100% of ICU only.
13 Providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component for
following Max. Rating erected as directed.
3.00 (iii) 63 Amps. FP Cat.III 3040.10 Ea.
14 41.00 Providing and erecting Miniature circuit breaker single pole
Ea. 6A to 25A suitable to operate on 240 V A.C. system and
having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark. Cat III
15 5.00 Providing and erecting Annealed bare Copper wire 8 to
SBD SECTION-7 BILL OF QUANTITIES-227
16 41.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
17 Supplying & erecting funnel type earthing having earth
plate of following size burred in specifically prepared earth
pit 3 mtr. below ground with 40 kg. charcoal and salt with
alternate layers of charcoal & salt, 20mm. dia. G.I. pipe
with Funnel with a wire mesh for watering & bricks masonry
block, C.I. Cover complete as per para 7.3 of IS 3043 with
necessary length of double Galvanised Iron / copper earth
wire No 6 SWG bolted with lug to the plate and covered in
12 mm dia. G.I. pipe 2.5 mtr long complete connected to
the nearest switch gear with end socket as per direction &
duly tested by earth tester confirming to IS (As per
drawing) with following specification.
3.00 (C) with 60 x 60 x 0.315 cms. Copper earth plate 7874.97 Ea.
18 3.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
19 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured
cable multistrand /Solid Aluminium conductor for 1.1 KV.
To be laid on wall with necessary clamps or in existing
trench/pipe of following size of cables
615.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
20 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables
102.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
21 615.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to IS
14930 II) with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable. (C)
22 Supplying following size of Light duty “A” Class G.I. Pipe &
erecting as directed by Engineer-in-charge.
23 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
82.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QUANTITIES-228
24 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
6.00 (d) 2 to 4 core 16 Sq. mm 47.47 Ea.
25 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
6.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
26 41.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
MCB Mounting, stud type terminal and arrangement for
cable termination to be erected With Suitable foundation
(Included) as per details given by manufacturer
considering site requirement. (D) 6 Mtr. Long 70 mm Top
X 135 mm bottom dia, 3 mm thickness with
200mmX200mmX12mm base plate, 4-M20 Bolts and
600mm long with necessary G.I. J Bolts .Approx Pole
27 Providing and erecting Street Light pole bracket comprising
main B Class MS pipe of 4.2 cm/require outside dia.
complete with suitable B Class M.S. sleeve tubing of
approx. 45cms.length and suitable for 76.5 mm /80mm /
required size of pole top having sufficient fasteners for
fixing the brackets and having spread of 1.5.mtr. length
with 110 deg.with vertical plane & suitable welded stays,
reducer and with check nuts complete painted with one
coat of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of arms.
41.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
SBD SECTION-7 BILL OF QUANTITIES-229
28 41.00 Supplying and erecting LED street light / Flood light fittings
Ea. with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more
than 0.95, THD < 10 %, CCT 3000 K to 5700K, Uniformity
ratio >0.45, Luminaire efficacy> 100 lumens/watt. LED
driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates) (NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges
shown.) (A) Street Light (IP-65), Surge protection -4KV
integral and Light must have 440VAC line supply with over-
voltage protection. (ii) above 36 to 48 Watts. Cat III
29 3.00 Supplying & erecting approved make Digital time switch
Ea. having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD
display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof thermoplastic
enclosure & transparent cover erected as required with
necessary connection erected as directed
30 3.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B) 2 pole
31 3.00 Supplying & erecting IP 55 grade following size section
Ea. pillar fabricated from joint less M.S. Sheet with angle iron
legs made from jointless M.S. Angle with cable clamps to
be buried in ground to have appropriate erection to work
uniform until erected with cement concrete foundation and
45 cm high bricks work finishing with plaster etc. hinged
double door internally supported on both side, with internal
and outside looking arrangement with look and keys in
duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one is
welded and other with nut and bolt for erecting Bakelite
sheet. Painting the Section Pillar inside and out side with
three tank powder coated paint. section pillar roof should
be without joint with water leakage proof & tested as per IP
55 test & followed by IS 2147 of 1962. (B) 75 X 60 X 45 cm
section pillar fabricated from 16 Gauge MS Sheet with
angle iron legs 45 cm long made from 35 X 35 X 5 mm
thick MS angle.
SBD SECTION-7 BILL OF QUANTITIES-230
32 41.00 Supplying & erecting approved make SMC press moulded
Ea. composite FRP. loop-in, loop- out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E), DIN
rail for mounting mob & hinged doors as per requirement
having locking arrangements with mounting clamp with
nuts, bolts & washers suitable for erection on pole with
cable clamps& earth bolt of following size of box. (c)
150mm x 125mm x 100mm [deep].
33 615.00 Making trench in Hard Murrum / Tar Road of suitable width
Mtr. of 90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same
and making the surface as normal ground.
34 90.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
35 1.00 GEB Connection Charges 50500.00 Job.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QUANTITIES-231
ZALOD MUNICIPALITY, ZALOD
ESTIMATE FOR PROVIDING, SUPPLYING & ERECTING OF LED STREET LIGHT POLE WITH ALL ACCESSORIES
FROM MADRESHA TO PADI MAHUDI AT ZALOD (WARD 6).
Sr. Quantity Discription Total Unit Amount
1 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured
copper cable 1.1 KV grade to be erected as directed of
following size.
264.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
2 2.00 Supplying & erecting following spare parts for panel
Ea. mounting Switch Disconnector Fuse Units. Operational
Handle Assembly Complete for (i) 32/63/125 Amps.
3 2.00 Supplying and erecting triple pole & neutral 440V / 500V
Rmt. panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each
bar, erected in existing cubical panel with necessary
connections. (A) Suitable for 100 Amp. Capacity.
4 2.00 Supplying & erecting following spare parts for panel
Ea. mounting Switch Disconnector Fuse Units. Neutral Link for
5 2.00 Supplying and erecting approved make 415V bakelite fuse
Ea. fittings for front connection / busbar type to accommodate
HRC fuse link, with spin - riveted brass contact, having
thermo plastic inflammable material & single piece
extruded brass box contact to lock with adequate cable
hole to accommodate aluminium conductors suitable for
(without HRC fuse). For 63 Amp.
6 2.00 Supplying and erecting Ammeter / Voltmeter selector
Ea. switch for 3 phase AC Supply 500 V on existing panel
board with necessary connections. 317.14 Ea.
7 2.00 Supplying and erecting approved make suitable panel
Ea. indicator LED type lamp, lens cover, complete erected with
necessary connections. 43.43 Ea.
8 2.00 Providing & erecting Spares For Air Circuit Breakers as
Ea. follows: (B) Auxiliary Contact Block for CN-CS 800 to
SBD SECTION-7 BILL OF QUANTITIES-232
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
165.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
165.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 50.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
Mtr. cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables.(e) 4 core 25 Sq. mm
12 2.00 Providing and erecting Approved make Four pole moulded
Ea. case circuit breaker having breaking capacity ICU of
KA. at 415 V,having normal current rating up to 25 A to
100A. with Fixed thermal & magnetic release suitable to
work on A.C. supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing
16 G.M.S. housing. Cat.III. ICS=100% of ICU only.
13 Providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component for
following Max. Rating erected as directed.
2.00 (iii) 63 Amps. FP Cat.III 3040.10 Ea.
14 33.00 Providing and erecting Miniature circuit breaker single pole
Ea. 6A to 25A suitable to operate on 240 V A.C. system and
having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark. Cat III
15 5.00 Providing and erecting Annealed bare Copper wire 8 to
SBD SECTION-7 BILL OF QUANTITIES-233
16 33.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
17 Supplying & erecting funnel type earthing having earth
plate of following size burred in specifically prepared earth
pit 3 mtr. below ground with 40 kg. charcoal and salt with
alternate layers of charcoal & salt, 20mm. dia. G.I. pipe
with Funnel with a wire mesh for watering & bricks
masonry block, C.I. Cover complete as per para 7.3 of IS
3043 with necessary length of double Galvanised Iron /
copper earth wire No 6 SWG bolted with lug to the plate
and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete
connected to the nearest switch gear with end socket as
per direction & duly tested by earth tester confirming to IS
(As per drawing) with following specification.
2.00 (C) with 60 x 60 x 0.315 cms. Copper earth plate 7874.97 Ea.
18 2.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
19 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured
cable multistrand /Solid Aluminium conductor for 1.1 KV.
To be laid on wall with necessary clamps or in existing
trench/pipe of following size of cables
660.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
20 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables
82.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
21 660.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to IS
14930 II) with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable. (C)
22 Supplying following size of Light duty “A” Class G.I. Pipe &
erecting as directed by Engineer-in-charge.
SBD SECTION-7 BILL OF QUANTITIES-234
23 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
66.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
24 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
4.00 (d) 2 to 4 core 16 Sq. mm 47.47 Ea.
25 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
4.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
26 33.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail
for MCB Mounting, stud type terminal and arrangement for
cable termination to be erected With Suitable foundation
(Included) as per details given by manufacturer
considering site requirement. (D) 6 Mtr. Long 70 mm Top
X 135 mm bottom dia, 3 mm thickness with
200mmX200mmX12mm base plate, 4-M20 Bolts and
600mm long with necessary G.I. J Bolts .Approx Pole
27 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following nos
33.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
SBD SECTION-7 BILL OF QUANTITIES-235
28 33.00 Supplying and erecting LED street light / Flood light fittings
Ea. with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more
than 0.95, THD < 10 %, CCT 3000 K to 5700K, Uniformity
ratio >0.45, Luminaire efficacy> 100 lumens/watt. LED
driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates) (NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges
shown.) (A) Street Light (IP-65), Surge protection -4KV
integral and Light must have 440VAC line supply with over-
voltage protection. (ii) above 36 to 48 Watts. Cat III
29 2.00 Supplying & erecting approved make Digital time switch
Ea. having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD
display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof thermoplastic
enclosure & transparent cover erected as required with
necessary connection erected as directed
30 2.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B) 2 pole
31 2.00 Supplying & erecting IP 55 grade following size section
Ea. pillar fabricated from joint less M.S. Sheet with angle iron
legs made from jointless M.S. Angle with cable clamps to
be buried in ground to have appropriate erection to work
uniform until erected with cement concrete foundation and
45 cm high bricks work finishing with plaster etc. hinged
double door internally supported on both side, with internal
and outside looking arrangement with look and keys in
duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one is
welded and other with nut and bolt for erecting Bakelite
sheet. Painting the Section Pillar inside and out side with
three tank powder coated paint. section pillar roof should
be without joint with water leakage proof & tested as per IP
55 test & followed by IS 2147 of 1962. (B) 75 X 60 X 45 cm
section pillar fabricated from 16 Gauge MS Sheet with
angle iron legs 45 cm long made from 35 X 35 X 5 mm
thick MS angle.
SBD SECTION-7 BILL OF QUANTITIES-236
32 33.00 Supplying & erecting approved make SMC press moulded
Ea. composite FRP. loop-in, loop- out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E), DIN
rail for mounting mob & hinged doors as per requirement
having locking arrangements with mounting clamp with
nuts, bolts & washers suitable for erection on pole with
cable clamps& earth bolt of following size of box. (c)
150mm x 125mm x 100mm [deep].
33 660.00 Making trench in Hard Murrum / Tar Road of suitable width
Mtr. of 90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same
and making the surface as normal ground.
34 30.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
35 1.00 GEB Connection Charges 50500.00 Job.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QUANTITIES-237
ZALOD MUNICIPALITY, ZALOD
ESTIMATE FOR PROVIDING, SUPPLYING & ERECTING OF LED STREET LIGHT POLE WITH ALL ACCESSORIES
FROM HANUMAN MANDIR TO BAYPASS CHOKADI AT ZALOD (WARD 6).
Sr. Quantity Discription Total Unit Amount
1 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured
copper cable 1.1 KV grade to be erected as directed of
following size.
264.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
2 2.00 Supplying & erecting following spare parts for panel
Ea. mounting Switch Disconnector Fuse Units. Operational
Handle Assembly Complete for (i) 32/63/125 Amps.
3 2.00 Supplying and erecting triple pole & neutral 440V / 500V
Rmt. panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of
following current carrying capacity, erected with necessary
bus bar supports /insulators, main cable socket to each bar,
erected in existing cubical panel with necessary connections.
(A) Suitable for 100 Amp. Capacity.
4 2.00 Supplying & erecting following spare parts for panel
Ea. mounting Switch Disconnector Fuse Units. Neutral Link for (i)
5 2.00 Supplying and erecting approved make 415V bakelite fuse
Ea. fittings for front connection / busbar type to accommodate
HRC fuse link, with spin - riveted brass contact, having
thermo plastic inflammable material & single piece extruded
brass box contact to lock with adequate cable hole to
accommodate aluminium conductors suitable for (without
HRC fuse). For 63 Amp.
6 2.00 Supplying and erecting Ammeter / Voltmeter selector switch
Ea. for 3 phase AC Supply 500 V on existing panel board with
necessary connections. 317.14 Ea.
7 2.00 Supplying and erecting approved make suitable panel
Ea. indicator LED type lamp, lens cover, complete erected with
necessary connections. 43.43 Ea.
8 2.00 Providing & erecting Spares For Air Circuit Breakers as
Ea. follows: (B) Auxiliary Contact Block for CN-CS 800 to 2500 &
SBD SECTION-7 BILL OF QUANTITIES-238
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if required.
165.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and bolts if required.
165.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 50.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
Mtr. cable multistrand Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing trench / pipe of
following size of cables.(e) 4 core 25 Sq. mm
12 2.00 Providing and erecting Approved make Four pole moulded
Ea. case circuit breaker having breaking capacity ICU of 25 KA.
at 415 V,having normal current rating up to 25 A to 100A.
with Fixed thermal & magnetic release suitable to work on
A.C. supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. Cat.III. ICS=100% of ICU only. 6173.12 Ea.
13 Providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for operation
on 3 phase and neutral 415V,50Hz. having characteristic of
quick action & tripping with all advance feature & do not
incorporate any electronic component for following Max.
Rating erected as directed.
2.00 (iii) 63 Amps. FP Cat.III 3040.10 Ea.
14 33.00 Providing and erecting Miniature circuit breaker single pole
Ea. 6A to 25A suitable to operate on 240 V A.C. system and
having breaking capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark. Cat III
15 5.00 Providing and erecting Annealed bare Copper wire 8 to
16 33.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
SBD SECTION-7 BILL OF QUANTITIES-239
17 Supplying & erecting funnel type earthing having earth plate
of following size burred in specifically prepared earth pit
mtr. below ground with 40 kg. charcoal and salt with
alternate layers of charcoal & salt, 20mm. dia. G.I. pipe with
Funnel with a wire mesh for watering & bricks masonry
block, C.I. Cover complete as per para 7.3 of IS 3043 with
necessary length of double Galvanised Iron / copper earth
wire No 6 SWG bolted with lug to the plate and covered in
mm dia. G.I. pipe 2.5 mtr long complete connected to the
nearest switch gear with end socket as per direction & duly
tested by earth tester confirming to IS (As per drawing) with
following specification.
2.00 (C) with 60 x 60 x 0.315 cms. Copper earth plate 7874.97 Ea.
18 2.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
19 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured
cable multistrand /Solid Aluminium conductor for 1.1 KV. To
be laid on wall with necessary clamps or in existing
trench/pipe of following size of cables
660.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
20 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing trench / pipe of
following size of cables
82.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
21 660.00 Providing & laying approved make Double walled corrugated
Mtr. pipes (DWC) of polyethylene (conforming to IS 14930 II) with
necessary connecting accessories of same material at
required depth in existing trench for laying of cable. below
ground / road surface for enclosing cable. (C) 50 mm Dia
22 Supplying following size of Light duty “A” Class G.I. Pipe &
erecting as directed by Engineer-in-charge.
23 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for following
size of cables.
66.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QUANTITIES-240
24 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for following
size of cables.
4.00 (d) 2 to 4 core 16 Sq. mm 47.47 Ea.
25 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for following
size of cables.
4.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
26 33.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as per
IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
MCB Mounting, stud type terminal and arrangement for cable
termination to be erected With Suitable foundation
(Included) as per details given by manufacturer considering
site requirement. (D) 6 Mtr. Long 70 mm Top X 135 mm
bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M20 Bolts and 600mm long with necessary G.I.
J Bolts .Approx Pole weight 59 kgs.
27 Providing and erecting Street Light pole bracket comprising
main B Class MS pipe of 4.2 cm/require outside dia.
complete with suitable B Class M.S. sleeve tubing of approx.
45cms.length and suitable for 76.5 mm /80mm / required
size of pole top having sufficient fasteners for fixing the
brackets and having spread of 1.5.mtr. length with
deg.with vertical plane & suitable welded stays, reducer and
with check nuts complete painted with one coat of Red oxide
/ PU base primer and two coats of Aluminium / PU paint.
paint with following nos of arms.
33.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
SBD SECTION-7 BILL OF QUANTITIES-241
28 33.00 Supplying and erecting LED street light / Flood light fittings
Ea. with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD
< 10 %, CCT 3000 K to 5700K, Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt. LED driver efficiency >
85 %.( fittings required LM-79 & LM-80 certificates) (NOTE:
Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) (A) Street Light (IP-
65), Surge protection -4KV integral and Light must have
440VAC line supply with over-voltage protection. (ii) above
36 to 48 Watts. Cat III
29 2.00 Supplying & erecting approved make Digital time switch
Ea. having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating contacts
Minimum switching setup time 1 minimum & LCD display.
Also comprised permanent ON/OFF switching. Programming
switches & housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary
connection erected as directed
30 2.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B) 2 pole
31 2.00 Supplying & erecting IP 55 grade following size section pillar
Ea. fabricated from joint less M.S. Sheet with angle iron legs
made from jointless M.S. Angle with cable clamps to be
buried in ground to have appropriate erection to work
uniform until erected with cement concrete foundation and
45 cm high bricks work finishing with plaster etc. hinged
double door internally supported on both side, with internal
and outside looking arrangement with look and keys in
duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one is
welded and other with nut and bolt for erecting Bakelite
sheet. Painting the Section Pillar inside and out side with
three tank powder coated paint. section pillar roof should be
without joint with water leakage proof & tested as per IP
test & followed by IS 2147 of 1962. (B) 75 X 60 X 45 cm
section pillar fabricated from 16 Gauge MS Sheet with angle
iron legs 45 cm long made from 35 X 35 X 5 mm thick MS
SBD SECTION-7 BILL OF QUANTITIES-242
32 33.00 Supplying & erecting approved make SMC press moulded
Ea. composite FRP. loop-in, loop- out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E), DIN
rail for mounting mob & hinged doors as per requirement
having locking arrangements with mounting clamp with nuts,
bolts & washers suitable for erection on pole with cable
clamps& earth bolt of following size of box. (c) 150mm x
125mm x 100mm [deep].
33 660.00 Making trench in Hard Murrum / Tar Road of suitable width of
Mtr. 90 cm or required depth for laying any size of cable or
locating the fault all over the run and back filling the same
and making the surface as normal ground.
34 30.00 If additional machinery like hammer driller or JCB use [Add]
Mtr. 297.95 Mtr.
35 1.00 GEB Connection Charges 50500.00 Job.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QUANTITIES-243
ZALOD MUNICIPALITY, ZALOD
ESTIMATE FOR PROVIDING, SUPPLYING & ERECTING OF LED STREET LIGHT POLE WITH ALL ACCESSORIES
FROM LAKHA BHAI HOUSE TO BHALABHAI HOUSE AT ZALOD (WARD 6).
Sr. Quantity Discription Total Unit Amount
1 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured
copper cable 1.1 KV grade to be erected as directed of
following size.
264.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
2 2.00 Supplying & erecting following spare parts for panel mounting
Ea. Switch Disconnector Fuse Units. Operational Handle Assembly
Complete for (i) 32/63/125 Amps.
3 2.00 Supplying and erecting triple pole & neutral 440V / 500V panel
Rmt. mounting Copper Busbars with four equal Nos. of electrolyte
bus having current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly wrapped with colour
insulating tape for phase sequence of following current
carrying capacity, erected with necessary bus bar supports
/insulators, main cable socket to each bar, erected in existing
cubical panel with necessary connections. (A) Suitable for
4 2.00 Supplying & erecting following spare parts for panel mounting
Ea. Switch Disconnector Fuse Units. Neutral Link for (i) 32/63/125
Amps. 137.36 Ea.
5 2.00 Supplying and erecting approved make 415V bakelite fuse
Ea. fittings for front connection / busbar type to accommodate HRC
fuse link, with spin - riveted brass contact, having thermo
plastic inflammable material & single piece extruded brass box
contact to lock with adequate cable hole to accommodate
aluminium conductors suitable for (without HRC fuse). For
6 2.00 Supplying and erecting Ammeter / Voltmeter selector switch
Ea. for 3 phase AC Supply 500 V on existing panel board with
necessary connections. 317.14 Ea.
7 2.00 Supplying and erecting approved make suitable panel indicator
Ea. LED type lamp, lens cover, complete erected with necessary
connections. 43.43 Ea.
8 2.00 Providing & erecting Spares For Air Circuit Breakers as
Ea. follows: (B) Auxiliary Contact Block for CN-CS 800 to 2500 &
SBD SECTION-7 BILL OF QUANTITIES-244
9 Mains with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays, power
switchgears, motor starters & control wiring) with required size
of copper lugs, nuts and bolts if required.
165.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel, relays, power
switchgears, motor starters & control wiring) with required size
of copper lugs, nuts and bolts if required.
165.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 50.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
Mtr. cable multistrand Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing trench / pipe of
following size of cables.(e) 4 core 25 Sq. mm
12 2.00 Providing and erecting Approved make Four pole moulded
Ea. case circuit breaker having breaking capacity ICU of 25 KA. at
415 V,having normal current rating up to 25 A to 100A. with
Fixed thermal & magnetic release suitable to work on A.C.
supply 50 c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S. housing.
Cat.III. ICS=100% of ICU only.
13 Providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on
phase and neutral 415V,50Hz. having characteristic of quick
action & tripping with all advance feature & do not incorporate
any electronic component for following Max. Rating erected as
2.00 (iii) 63 Amps. FP Cat.III 3040.10 Ea.
14 33.00 Providing and erecting Miniature circuit breaker single pole 6A
Ea. to 25A suitable to operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark. Cat III
15 5.00 Providing and erecting Annealed bare Copper wire 8 to
SBD SECTION-7 BILL OF QUANTITIES-245
16 33.00 Providing and erecting Pipe type earthing having 150 cms.long
Ea. and 2.5 cms. dia. galvanised iron pipe with coupling and buch
buried in specially prepared earth pit complete with necessary
8 SWG earth wire.
17 Supplying & erecting funnel type earthing having earth plate of
following size burred in specifically prepared earth pit 3 mtr.
below ground with 40 kg. charcoal and salt with alternate
layers of charcoal & salt, 20mm. dia. G.I. pipe with Funnel with
a wire mesh for watering & bricks masonry block, C.I. Cover
complete as per para 7.3 of IS 3043 with necessary length of
double Galvanised Iron / copper earth wire No 6 SWG bolted
with lug to the plate and covered in 12 mm dia. G.I. pipe
mtr long complete connected to the nearest switch gear with
end socket as per direction & duly tested by earth tester
confirming to IS (As per drawing) with following specification.
2.00 (C) with 60 x 60 x 0.315 cms. Copper earth plate 7874.97 Ea.
18 2.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
19 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured
cable multistrand /Solid Aluminium conductor for 1.1 KV. To be
laid on wall with necessary clamps or in existing trench/pipe of
following size of cables
660.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
20 Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe of
following size of cables
82.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
21 660.00 Providing & laying approved make Double walled corrugated
Mtr. pipes (DWC) of polyethylene (conforming to IS 14930 II) with
necessary connecting accessories of same material at
required depth in existing trench for laying of cable. below
ground / road surface for enclosing cable. (C) 50 mm Dia
22 Supplying following size of Light duty “A” Class G.I. Pipe &
erecting as directed by Engineer-in-charge.
SBD SECTION-7 BILL OF QUANTITIES-246
23 Providing and fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
66.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
24 Providing and fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
4.00 (d) 2 to 4 core 16 Sq. mm 47.47 Ea.
25 Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
4.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
26 33.00 Supplying and erecting approved make Octagonal pole made
Ea. from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB
Mounting, stud type terminal and arrangement for cable
termination to be erected With Suitable foundation (Included)
as per details given by manufacturer considering site
requirement. (D) 6 Mtr. Long 70 mm Top X 135 mm bottom
dia, 3 mm thickness with 200mmX200mmX12mm base plate,
4-M20 Bolts and 600mm long with necessary G.I. J Bolts
.Approx Pole weight 59 kgs.
27 Providing and erecting Street Light pole bracket comprising
main B Class MS pipe of 4.2 cm/require outside dia. complete
with suitable B Class M.S. sleeve tubing of approx.
45cms.length and suitable for 76.5 mm /80mm / required size
of pole top having sufficient fasteners for fixing the brackets
and having spread of 1.5.mtr. length with 110 deg.with vertical
plane & suitable welded stays, reducer and with check nuts
complete painted with one coat of Red oxide / PU base primer
and two coats of Aluminium / PU paint. paint with following nos
33.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
SBD SECTION-7 BILL OF QUANTITIES-247
28 33.00 Supplying and erecting LED street light / Flood light fittings with
Ea. High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD <
10 %, CCT 3000 K to 5700K, Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt. LED driver efficiency > 85 %.(
fittings required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Street Light (IP-65), Surge
protection -4KV integral and Light must have 440VAC line
supply with over-voltage protection. (ii) above 36 to 48 Watts.
29 2.00 Supplying & erecting approved make Digital time switch having
Ea. lithium cell 6 years operative and operate battery backup
channel day clock with 14 memory programme, suitable to
operate on 240V + 5%, 16A with, floating contacts Minimum
switching setup time 1 minimum & LCD display. Also
comprised permanent ON/OFF switching. Programming
switches & housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary
connection erected as directed
30 2.00 Supplying & erecting power contactor, AC3 duty for time switch
Ea. complete erected as per direction Cat III. (B) 2 pole 250V
Amp. 1883.65 Ea
31 2.00 Supplying & erecting IP 55 grade following size section pillar
Ea. fabricated from joint less M.S. Sheet with angle iron legs made
from jointless M.S. Angle with cable clamps to be buried in
ground to have appropriate erection to work uniform until
erected with cement concrete foundation and 45 cm high
bricks work finishing with plaster etc. hinged double door
internally supported on both side, with internal and outside
looking arrangement with look and keys in duplicate 35 x 35 x
5 mm M.S. Angle of Two Nos. one is welded and other with nut
and bolt for erecting Bakelite sheet. Painting the Section Pillar
inside and out side with three tank powder coated paint.
section pillar roof should be without joint with water leakage
proof & tested as per IP 55 test & followed by IS 2147 of
(B) 75 X 60 X 45 cm section pillar fabricated from 16 Gauge
MS Sheet with angle iron legs 45 cm long made from 35 X
X 5 mm thick MS angle.
SBD SECTION-7 BILL OF QUANTITIES-248
32 33.00 Supplying & erecting approved make SMC press moulded
Ea. composite FRP. loop-in, loop- out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E), DIN rail
for mounting mob & hinged doors as per requirement having
locking arrangements with mounting clamp with nuts, bolts &
washers suitable for erection on pole with cable clamps& earth
bolt of following size of box. (c) 150mm x 125mm x 100mm
33 660.00 Making trench in Hard Murrum / Tar Road of suitable width of
Mtr. 90 cm or required depth for laying any size of cable or locating
the fault all over the run and back filling the same and making
the surface as normal ground.
34 30.00 If additional machinery like hammer driller or JCB use [Add]
Mtr. 297.95 Mtr.
35 1.00 GEB Connection Charges 50500.00 Job.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QUANTITIES-249
ZALOD MUNICIPALITY, ZALOD
NAME OF WORK :- ESTIMATE FOR CONSTRUCTION WORK OF C. C. ROAD AT KALUBHAI'S HOUSE TO
LAXMANBHAI'S HOUSE AT ZALOD ( WARD 6 )
Qty. Description Unit Amount
1 57.00 Demolition and disposal of unserviceable materials with
Cmt. all lead and lift.(i) Lime concrete.
2 113.50 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt. Lead
3 57.00 Providing and laying compacted 100 mm thick B.T.
Cmt. Metalling (45 to 63 mm size) using Stone screening
mm of 0.16 Cmt./10 Smt. and 0.08 Cmt./10 Smt., Stone
Dust including spreading in uniform layer, watering and
consolidation by vibratory roller achived the desired
density, as per clause.404 of M.O.R.T. & H. specification
4 57.00 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt. 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of formwork
in foundation and plinth.
5 85.50 Providing and laying cement concrete work M200 and
Cmt. curing complete excludng the cost of form work an
reinforcement of reinforced concrete work.
6 567.00 Labour charges for concreting with vacume dewatering
Smt. Technique (Trimix or equivalent type) including loading,
unloading, carting, companing complete with "C"
channelas as per requirement and labour charges on
directed by Engineer-in-charge.
SBD SECTION-7 BILL OF QUANTITIES-250
7 7.00 Renovation of manhole by increasing the height at top
Nos. including cost of excavation, refitting of C. I. manhole
frame and cover curing etc. complete incl. all carting and
providing of materials which is required for the purpose
(except manhole frame and cover) For all type manhole
by providing RCC 1:2:4 Partition walls with required
reinforcement 25 cm thick and circular opening with
500mm clear dia and 0.40 mt. av. ht.
8 17.10 Supplying promoulded bituminous joint filler. (I) 12mm
Cmt thick 553.79 Cmt
Add :- 18% GST Rs.
Add :- 2% of Contingency Charges Rs.
Add :- 1% of Qaulity Controll Rs.
SBD SECTION-7 BILL OF QUANTITIES-251
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ.pdf
Notes.pdf
OTHER IMPORTANT-1.pdf
OTHER IMPORTANT-2.pdf
OTHER IMPORTANT-3.pdf
SBD.pdf
Download all tender documents and submit your bid