The Sr. VP (P&C)
Procurement of 2250 KVA (2 Nos.) & 1010 KVA (3 Nos.) DG set for Backup Power Supply arrangements in Block-15 (SEZ area), Block-48, 53 & 56 (DTA area) of GIFT City
268258
GIFT/ENG/EL/SC/2026/01
Open
Electrical Works
Fixed-rate
Gandhinagar
2 documents required · 2 mandatory
₹10,000
Yes
GIFT Power Company Limited
₹15.4 L
Yes
22 Jan 2026
22 Jan 2026
22 Jan 2026
5 Feb 2026
22 Jan 2026
1200016468 SITC 2250 kVA LT DG exhaust & retrofit Design, manufacture, supply, testing, loading at manufacturers place, transit, lifting-unloading, erection at site, testing, commissioning including performance testing of Prime rated LT Diesel Generator set of 2250 kVA with 4 stroke, multi cylinder 2250 kWm or above engine coupled to brush less type, 415 volts, 50 cycle/second, self-exited (PMG) alternator of 2550 kVA or above capacity completed with cushy pads, silencer complete with alternator auxiliaries, acoustic enclosure (silent type enclosure as per CPCB), electronic governor, 24 volts chargeable battery with redundancy including initial charging of batteries with battery charger, day tank below DG, 990 litters diesel storage tank along with required fuel piping with auto fuel pumping arrangement, valves, strainer, clamps and connector. The DG set shall be as per Latest amendments of MOEF and CPCB Including retrofit emission control device / equipment in DG set as per GPCB latest circular. The work includes auto changeover battery supply system, earthing work, redundant full tank diesel (990 ltr.) while handing over after field testing, fuel & testing charges, liaison work, N+N redundant battery, etc. It also includes DG set approval from GPCB and CEIG. All complete work as per specification and installation and approvals on the proposed location of DG set.
1200016469 SITC 1010 kVA LT DG exhaust & retrofit Design, manufacture, supply, testing, loading at manufacturers place, transit, lifting-unloading, erection at site, testing, commissioning including performance testing of Prime rated LT Diesel Generator set of 1010 kVA with 4 stroke, multi cylinder 1010 kWm or above engine coupled to brush less type, 415 volts, 50 cycle/second, self-exited (PMG) alternator of 1150 kVA or above capacity completed with cushy pads, silencer complete with alternator auxiliaries, acoustic enclosure (silent type enclosure as per CPCB), electronic governor, 24 volts chargeable battery with redundancy including initial charging of batteries with battery charger, day tank below DG, 990 litters diesel storage tank along with required fuel piping with auto fuel pumping arrangement, valves, strainer, clamps and connector. The DG set shall be as per Latest amendments of MOEF and CPCB Including retrofit emission control device / equipment in DG set as per GPCB latest circular. The work includes auto changeover battery supply system, earthing work, redundant full tank diesel (990 ltr.) while handing over after field testing, fuel & testing charges, liaison work, N+N redundant battery, etc. It also includes DG set approval from GPCB and CEIG. All complete work as per specification and installation and approvals on the proposed location of DG set.
Item Description
1200016468 SITC 2250 kVA LT DG exhaust & retrofit Design, manufacture, supply, testing, loading at manufacturers place, transit, lifting-unloading, erection at site, testing, commissioning including performance testing of Prime rated LT Diesel Generator set of 2250 kVA with 4 stroke, multi cylinder 2250 kWm or above engine coupled to brush less type, 415 volts, 50 cycle/second, self-exited (PMG) alternator of 2550 kVA or above capacity completed with cushy pads, silencer complete with alternator auxiliaries, acoustic enclosure (silent type enclosure as per CPCB), electronic governor, 24 volts chargeable battery with redundancy including initial charging of batteries with battery charger, day tank below DG, 990 litters diesel storage tank along with required fuel piping with auto fuel pumping arrangement, valves, strainer, clamps and connector. The DG set shall be as per Latest amendments of MOEF and CPCB Including retrofit emission control device / equipment in DG set as per GPCB latest circular. The work includes auto changeover battery supply system, earthing work, redundant full tank diesel (990 ltr.) while handing over after field testing, fuel & testing charges, liaison work, N+N redundant battery, etc. It also includes DG set approval from GPCB and CEIG. All complete work as per specification and installation and approvals on the proposed location of DG set.
1200016469 SITC 1010 kVA LT DG exhaust & retrofit Design, manufacture, supply, testing, loading at manufacturers place, transit, lifting-unloading, erection at site, testing, commissioning including performance testing of Prime rated LT Diesel Generator set of 1010 kVA with 4 stroke, multi cylinder 1010 kWm or above engine coupled to brush less type, 415 volts, 50 cycle/second, self-exited (PMG) alternator of 1150 kVA or above capacity completed with cushy pads, silencer complete with alternator auxiliaries, acoustic enclosure (silent type enclosure as per CPCB), electronic governor, 24 volts chargeable battery with redundancy including initial charging of batteries with battery charger, day tank below DG, 990 litters diesel storage tank along with required fuel piping with auto fuel pumping arrangement, valves, strainer, clamps and connector. The DG set shall be as per Latest amendments of MOEF and CPCB Including retrofit emission control device / equipment in DG set as per GPCB latest circular. The work includes auto changeover battery supply system, earthing work, redundant full tank diesel (990 ltr.) while handing over after field testing, fuel & testing charges, liaison work, N+N redundant battery, etc. It also includes DG set approval from GPCB and CEIG. All complete work as per specification and installation and approvals on the proposed location of DG set.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Bid document_DG Set.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .