Tender Value
₹99.4 L
EMD Value
₹2.0 L
Closing Date
26 Feb 2026, 3:00 pmClosed
Executive Engineer IE Division Agart
Office of the Executive Engineer IE Division Agartala
Construction of 15 nos. Non-Type and Type VI quarters at Agartala, West Tripura SH Building portion including internal water supply, Sanitary installation, Sewage and Drainage and Internal Electrification works SH Balance Electrical Works thereof
2026_CEPWD_70658_1
ACE/PU/PWD (Bldgs)/Elect/DNIT/28/2025-26
Open Tender
Electrical Works
Percentage
180 days
Agartala
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,000
₹2.0 L
11 Jun 2026
20 Feb 2026
26 Feb 2026
20 Feb 2026
26 Feb 2026
20 Feb 2026
Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 + 1x1.5 sq. mm PVC insulated copper conductor cable (FR) in existing PVC conduit/PVC roll pipe (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc. as required:-
Wiring for 2 way controlling light point with 3x1.5 sq. mm + 1x1.5 sq. mmPVC insulated copper conductor cable (FR) in existing PVC conduit/PVC roll pipe (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type 2 way switch, cover plate, GI box including necessary connection etc. as required:-
Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required:
Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required:-
Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall etc. as required:-
2x1.5+1x1.5 sq mm
2x2.5+1x1.5 sq mm
2x4+1x1.5 sq mm
2x6+1x2.5 sq mm
4x6+2x2.5 sq mm
4x10+2x4 sq mm
4 X 16 + 2 X 6 sq mm
Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-
1X 1.5 sq mm
1X 2.5 sq mm
1X 4 sq mm
2 X 1.5 sq mm
2 X 2.5 sq mm
2 X 4 sq mm
2 X 6 sq mm
2 X 10 sq mm
4 X 6 sq mm
4 X 10 sq mm
4 X 16 sq mm
Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.
19/20 mm dia
25 mm dia
Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required.
Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.
Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12"x 12" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:-
Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required.
Supply and fixing of 32mm x 6 mm Copper strip on walls/ floor of the building for hoizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals:-
Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-
Short Point :-
Medium Point :-
Long Point :-
Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
2 X 1.5 sq mm
2 X 2.5 sq mm
4 x 6 sqmm
Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required(Ics=100% of Icu with adjustable settings):
125 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :-
Supplying & installation of powder coated sheet steel enclosure(MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required:-
(2+6) way SPN MCB DB (double door):-
6 way horizontal TPN MCB DB (Double door)
12 way horizontal TPN MCB DB(Double door)
4 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):-
6 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door)
Supplying & installation of 10 KA breaking capacity,B/C curve MCB of following ratings in the existing Panels/MCB DBs including necessary connections etc as required:-
6 to 32 amps SP MCB
40 amps DP MCB:
12 way horizontal TPN MCB DB(Double door)
40/50/63 amps FP MCB:-
Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required:
1-2 module GI switch board
4 module GI switch board:-
Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required:-
1-2 module
3 module
4 module
6 module
8 module
12 module
Supplying & fixing of the following modular accessories including necessary connection etc. as required:-
6/10 amps one way SP switch (1M) with indicator:-
6/10 amps two way SP switch (1M) with indicator
16/20 amps one way SP switch (1M) with indicator
3 pin 6/10 amps socket outlet (2M)
3/6 pin 16/20 amps socket outlet (2M)
Bell push SP with indicator (1M)
5 step fan regulator (2M)
TV socket outlet(1M)
RJ11 telephone socket outlet (1M)
RJ45 LAN socket outlet (1M)
20/25 amps single phase motor starter switch (2M)
Blank Plate (1M)
LED foot lamp (WW/CW) (2M)
32 amps one way DP switch with indicator (2M)
Supplying and fixing of the following electrical accessories including necessary connection etc. as required:-
Remote controlled call bell
15 amps power top
32 amps DP kit kat switch
3mm thick bakelite sheet
Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :-
Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-
Supplying & installation of 250mm / 300 mm plastic exhaust fan (Ventilating Fan) including connection etc as required:-
Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:-
Supplying and fixing of following vertical storage water heater 5 star catagory complete with 15 amps top, connection pipes including necessary connection etc as required:-
25 litre storage capacity
Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : -
Supplying and fixing of 900mm / 1200 mm sweep pearl white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) etc. as required
Supplying & installation of 450 mm sweep wall mounting air circulator including connection etc as required:-
Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
Supplying and fixing of surface mounted round / square 15 watt LED downlight of tri-colour (CW/NW/WW) complete with all necessary accessories including connection etc. as required.
Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:
Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:
Supplying and fixing of Mirror lightcomplete with all necessary accessories including connection etc. as required.
Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
60 watt LED street light fixture with integral driver and secondary lens (IP 66)
Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-
40 mm dia
Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink
Supplying and fixing of outdoor LED Rope light of 45 mtr length (Warm White) & 60L/mtr, IP 65 and necessary accessories including necessary connection etc. as reqd.
Supplying and fixing of driver for LED rope light of 45 mtr length & 60L/mtr, and necessary accessories including necessary connection etc. as reqd.
Supplying and fixing of 40 Watt LED post top light complete with all necessary accessories including connection etc. as required.
Supplying and fixing of 28 Watt LED post top light complete with all necessary accessories including connection etc. as required.
Supplying and fixing of ground bollard for outdoor application complete with all necessary accessories including connection etc. as required.
Supplying and fixing of 1 (one) light Pole light for outdoor complete with all necessary accessories including connection etc. as required.-
Supplying and fixing of 2 (TWO) Way Pole light for outdoor complete with all necessary accessories including connection etc. as required.
Supplying and fixing of 3 (Three) Way Pole light for outdoor complete with all necessary accessories including connection etc. as required.
Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required
3 core 1.5 Sq mm
Supplying and laying of the following sizes XLPE insulated PVC sheathed Copper conductor un-armoured cable in 32 mm dia HDPE pipe as cassing pipe with necessary connection etc as required
4 core 2.5 Sq mm
4 core 4 Sq mm
4 core 10 Sq mm
Supplying and laying of the following sizes XLPE insulated PVC sheathed Copper conductor un-armoured cable in 50 mm dia HDPE pipe as cassing pipe with necessary connection etc as require
4 core 35 Sq mm
Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes:-
Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required
Supplying & fixing of 12mm thick marine plywood conforming to IS:710 with necessary painting etc as required:-
Supplying & fixing of 12mm thick marine plywood conforming to IS:710 with necessary painting etc as required:-
Supplying and laying of the following sizes HDPE Pipes (PE-11) as per BIS standard marked conforming to IS: 4984:2016 with necessary accessories etc as required:-
32 mm size
32 mm size
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size)
SCentering shuttering including struttings, propping etc and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:-
6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):-
Neat cement punning
Supplying, installation, testing and commissioning of following ratings online UPS with inbuilt isolation transformer, 50/60Hz (Auto sensing) frequency, P.F range 0.95-0.99, voltage regulation +/-1%, Pure sine wave form, total harmonic distortion < 5% with full load, Noise level 50db at 1m, LED indication for Normal mode/Load on battery/Load on bypass/System fault, Audible alarm for Mains failure, low battery, Overload, fault and Bypass mode complete with M. S Rack for mounting battery bank, Battery inter link cables and all other necessary accessories including connections etc. as required:
10 kVA, 3 Ph input/1 Ph output Online UPS with 19200 VAH battery bank for minimum 1 hour Backup:-
Supplying, installing, testing and commissioning of OPR 60 ESE LIGHTNING ARRESTOR with a protection radius of 107 mtrs in level IV with a trigger time ΔT = 60 micro seconds as per NF C 17-102 (2011) standard (Model: 2CTB899800R7100, ABB make) with all necessary accessories including connection etc as required
Supplying and installing mounting mast of 2 mtrs height to couple OPR ESE lightning Arrestor with all necessary accessories incuding connection etc. as required (ABB make):-
Supplying and installing mounting mast of 3 mtrs height complete with base plate and guy wire and all other necessary accessories incuding connection etc. as required
Supplying and installing lightning strike counter with all necessary accessories incuding connection etc. as required
Supplying and installing 17.2mm dia copper bonded earth rod 03 mtrs in length tested with IEC 62561 with all necessary accessories incuding connection etc. as required
Supplying and making use of 25kg bag of ground resistance improvement compound FURSECEM powder with all necessary accessories etc. as required
Supplying and installing rod to tape clamp (25x3 tape to 17mm rod) of copper alloy with all necessary accessories including connections etc. as required:-
Supplying and installing inspection pit cover plate with IEC 62561 with all necessary accessories including connections etc. as required
Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required
1x70 sq mm:-
Supplying & drawing of RG-59 co-axial unarmoured cable in the existing PVC conduit/ casing caping i/c necessary Conn. etc as reqd
Supplying & drawing of 2 pairs 0.5 sqmm unarmoured telephone cable in the existing PVC conduit/ casing caping i/c necessary Conn. etc as reqd
Supplying, installation, testing and commissioning of 160 kVA DG set as per CPCB-IV+ compliance with double breaker (MCCB, Ics=100% Icu of suitable ratings), 3 ph, 415 Volt, 1500 rpm, 50 Hz, 0.8 pf (lag) with 6 (six) cylinder
Supplying, Installation, Testing and Commissioning of AMF PANEL BOARD WITH AUTO MANUAL OPERATION (DG START - STOP) with BY-PASS facility, IP42 with complete internal wiring including all electrical instruments. FABRICATION : 14 SWG - CRCA Sheet (2mm) PAINTING: Powder Coated SIEMENS GREY Shed (RAL 7032)/ Pre Treatment 9 Tank Chemical Treatment TYPE : Free Floor Resting, Fix Type, Single Door, Compartmentalized Design. BUSBAR Aluminium CABLE ENTRY: Top/Bottom(Detachable Gland Plate Undrilled) INCOMMER 250A 25KA 4P MCCB + SPDL + ROH - 2 SET 255A 4P CONTACTOR - 2 NOS METERING SECTION DIGITAL DC VOLTMETER - 1 NOS DIGITAL MFM METER - 2 SET LED RYB - 2SET ON - OFF - 2SET BATTERY CHARGER 24VDC - 1 NOS OUTGOING 125A 25 KA MCCB + SPDL + ROH - 4 NOS
Supplying and filling of HS Diesel oil for 160 kVA DG set
Supplying and fixing of TIERED CANDLE CHANDELIERS model "PICTOR" with Asfour Almaaza Crystal & SK Gold Finish ( D-1450 x H-2100 mm) as per cat no.-DTD-SKG-ASPIC0095430C of Jaquar make in/c necessary connection etc. as required
stage.html
html • 0.03 MB
finance_71905.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.09 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.79 MB
BOQ_71905.xls
BOQ • 0.57 MB
DNIT.pdf
Tender Documents • 2.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .