| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹33.0 L+₹2.5 L (8.16%)Rejected-AOC 0 0 NAGLA MALOO MOHAMMDABAD FARRUKHABAD FARRUKHABAD FARRUKHABAD UTTAR PRADESH 209625 | FARRUKHABAD | UTTAR PRADESH | 209625 | L2 | Rejected-AOC ok | |
| 3 | L3₹33.1 L+₹2.7 L (8.71%)Rejected-AOC | L3 | Rejected-AOC ok | |
| 4 | L4₹33.3 L+₹2.9 L (9.38%)Rejected-AOC 37 2 INDIRA COLONY CHUKHUWALA DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC ok | |
| 5 | L5₹33.7 L+₹3.2 L (10.4%)Rejected-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC ok |
Tender Value
₹38.9 L
EMD Value
₹77,800
Closing Date
21 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Dehradun
HQ CWE Dehradun
SPECIAL REAPIR FOR OFFICER MD ACCN NO P-35 AT BINDAL BRIDGE UNDER GE DEHRADUN
2021_MES_496919_1
9657/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹77,800
Yes
10 Feb 2022
23 Dec 2021
24 Jan 2022
23 Dec 2021
21 Jan 2022
7 Jan 2022
60 days
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plastering of any description on brick/stone/concrete wall surfaces of any description including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth complete all as specified and as directed.
M & L for rendering 10mm thick in cement mortar 1:3 on fair faces of concrete work even and smooth as in ceiling complete all as specified and as directed.
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed.
M&L for preparation of new plastered surface of walls including corners and applying two coats of distemper oil emulsion over and including a coat of 1-2mm thick wall care putty finish wall surface even & smooth complete all as specified and directed.
M&L for complete removal of existing treatment of walls including corners and applying two coats of distemper oil emulsion over a coat of 1-2mm thick wall care putty, finished surface even & smooth complete all as specified and directed.
M&L for complete removal of existing treatment of ceiling and applying two coat of white wash on of ceiling complete all as specified and directed.
M&L for preparation of new plastered surface of external wall and applying two coats of exterior grade 1st quality weather coat paints over a coat of alkali resistant priming paint including applying of exterior grade wall care putty 1 to 1.5 mm thick in two coat to make the surface smooth complete all as specified and directed.
M&L for complete removal of existing treatment painted surfaces of external wall with scrapping, wire brushing, washing with water preparation of old plastered surfaces of external wall and applying two coats of exterior grade 1st quality weather coat paints over a coat of alkali resistant priming paint including applying of exterior grade wall care putty 1 to 1.5 mm thick in two coat to make the surface smooth complete all as specified and directed.
M&L for two coat of synthetic enamel paint over a coat of red oxide primer including preparation on new steel surfaces of any description over 10 cm width or girth complete all as specified and as directed.
Preparation of old Steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new wooden painted surfaces including preparation and applying two coat of synthetic enamel paint any description, over a coat of pink primer, not otherwise described, over 10 cm width/girth complete all as specified and directed.
M&L for preparation of old painted surfaces of wood over 10 cm width/girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement motor bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for vitrified ceramic tiles dark shed /double charged 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. over and including screed bed 15 mm thick in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile adhesive complete all as specified and as directed.
M&L for vitrified ceramic tiles dark shed /double charged 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in skirting over and including 10 mm thick rendering in cement mortar 1:4, complete complete all as specified and as directed.
M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm and 6 to 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 350mm x250mm x 7mm/ 450x 350 x 7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Demolition of stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and as directed.
S&F granite 20mm thick of any type ( table rubbed and polished in steps, jambs pillars, window cill, cooking platform and like in cement mortar 1:4 including pointing in white cement complete all as specified and directed.
Demolition of cement concrete ground floor and paving nexc 15cm thick (below or above ground level) and dispose with in the MD land complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement and demolition of existing old cement concrete of plinth protection in ground floor and paving below or above ground level complete all as specified and as directed.
M&L for Cement concrete type D2 1:4:8 (using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Taking down chowkat with shutter n. exc 1.5 Sqm each complete all as specified and as directed.
Taking down chowkat with shutter exc 1.5 Sqm but n. exc 4 Sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm n.exc 2 sqm each and refixing in same opening after necessary repair complete all as specified and as directed.
Taking down shutter only n.exc 1.00 sqm each complete all as specified and as directed.
S&F 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door shall be water proof, termite proof, fire retardant and having screw holding capacity complete all as specified and as directed.
S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity complete all as specified and as directed.
S & F 35mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) complete all as specified and as directed.
S & F for Anodised aluminium frame for doors, windows ventilators (Powder Coated) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S & F for 18/19mm thick Pre laminated particle, board, exterior grade, pre laminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to aluminium frame work, complete all as specified and as directed.
S & F sheet glass 4mm thick, ordinary quality and glazing fixed in aluminium frame with and including aluminium beading in square exc 0.5 sq.m in each pane including fixing of PVC gas kit and beading, complete all as specified and as directed.
S & F Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete with glazing bars dovetailed or welded with one shop coat of primer complete all as specified and directed.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete without glazing bars, as fly proof shutters with one shop coat of primer complete all as specified and directed.
S&F factory made steel windows or ventilators, fixed type, with glazing bars complete all as specified and as directed.
S & F PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as shown in SSR Part – II, 2020 and complete all as specified and as directed.
S&F mild steel flat iron for hold fasts and similar articles complete all as specified and ditected.
M&L cutting holes in brick wall built in cement mortar exc half brick but n.exc one brick for inserting or cement concrete 1:2:4 hold fast etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 complete all as specified and as directed.
S&F 200 mm long, solid in one piece stainless steel barrel tower bolts complete all as specified and as directed.
S&F 150 mm long, solid in one piece stainless steel barrel tower bolts complete all as specified and directed.
S&F 150mm size solid in one piece stainless steel handles, cast D type, fixed in stainless steel screws complete all as specified and as directed.
S&F 125mm size solid in one piece stainless steel handles, cast D type, fixed in stainless steel screws complete all as specified and as directed.
S&F 100 mm size stainless steel butt hinges and fixed with stainless steel screws, complete all as specified and directed by Engr-in-Charge.
S&F 75 mm size MS butt hinges medium weight cold rolled fixed/ welded to frame complete all as specified and as directed.
S&F stainless steel sliding door bolts 204 grade, hasp and staple type with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long complete all as specified and as directed.
S&F stainless steel 304 grade wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples with 8% nickle complete all as specified and as directed.
S&F in repairs Stainless steel 304 grade wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples with 8% nickle complete all as specified and ditected.
Hacking out old broken glass ( any thickness , size, quality, or description) from wooden frame glazed with putty or fixed with beads complete all as specified and as directed.
M & L sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc 0.5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and as directed.
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
S&F powder coated aluminium grill with mesh size 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc. aluminium section 15 micron thick anodizing complete all as specified and directed including taking down old grill and removing from site.
S & F Continuous (Piano) hinges, mild steel, bright finished or stainless steel 304 grade, width of flaps (When open) 30 mm complete all as specified and ditected.
S&F stainless steel CP semi hydraulic albehari hinges complete all as specified and as directed.
S&F ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F in repair peg set of five stainless steel fixed on CP steel plate 304 grade including fixing complete all as specified and as directed.
S&F in repairs glass corner shelf suitable size made of 5mm thick toughned complete all as specified and as directed.
S&F in repair 25 mm dia stainless steel polished 204 grade drapery rod 1mm thick with final decorative, including brackets,knobs, decorative finished at both ends complete all as specified and directed as per approved sample.
S & F Solid PVC wall Lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing including removing existing unserviceable wall lining complete all as specified and as directed.
S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F PVC Shelves 450mm of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed. Minimum weight 300 gms.
S&F in repair stainless steel plate rack 20 gauge overall size 600x750x220 mm of standard pattern and make as approved by GE complete all as specified and as directed.
S&F in repairs stainless steel kitchen sinks with draining board ISI marked made of stainless steel 1 mm thick, with plugs, washers and wastes, including bedding lime cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed.
Demolition of reinforced cement concrete, shelves, chajjas, slabs and similar work carefully and matching to adjoining disturbed surfaces all as directed.
M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and colums, in floors, roofs, landing balconies, canopies, deck slabs, chajja and in shelves and the like, complete all as specified and directed. Note : The work will be carried out upto triple story building the rate of scaffolding is included for this item also complete all as specified and as directed.
Use and waste form work to soffit of RCC Slab such as roof slab, chajja, floor slab etc complete all as specified and as directed.
Use and waste form work to edges of concrete flats, treads, break in floor & roofs n. exec 20 cm wide horizontal or sloping and similar works complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cills, copings, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
S&F mild steel TMT MS bar 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed..
S&F in repair mild steel framed work such as grills, gratings, etc., with ends of bars shouldered or riveted, or forged into spikes; framed guard bars; barred iron doors and similar work conforming to Fe 210,Gde E-165 complete all as specified and as directed.
Taking up or down steel tubing and connections with all fittings for 15 mm bore GI tubing complete all as specified and as directed.
Taking up or down steel tubing and connections with all fittings for 20 mm bore GI tubing complete all as specified and as directed.
M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth complete all as specified and as directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing complete all as specified and as directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing complete all as specified and as directed.
S&F rotational moulded polyethylene 500 Ltrs Capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including dismantling old unserviceable tank complete all as specified and as directed.
S&F in repair ball valve high pressure of PTMT with epoxy coated alum rod & high density plastic ball screwed for 15mm bore iron pipe and fixed (minimum weight 20mm -210 gms) complete all as specified and directed.
S&F in repair CP toilet paper holder complete all as specified and as directed.
S&F in repair CP Brass 3 in 1 hot & cold 15 mm dia wall mixer for mixing hot & cold water with telephonic shower provision with connecting legs & flanges complete all as specified and directed.
S&F in repair CP brass Central hole basin mixer fancy type 15mm dia complete all as specified and as directed.
S&F in repair CP brass bib tap fancy type 15mm bore screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repair 15mm bore Bib taps long body, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair CP 15 mm brass angle valves (2 in 1), fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair PVC Health Faucet with 1 mtr metallic expandable tube & hook complete all as specified and as directed.
S&F in repairs 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified and as directed.
S&F in repair CP brass shower rose with arm 15mm dia and shower 100mm dia complete all as specified and directed.
S & F in repairs wash down water closet (EWC) white with P or S trap including Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern and plastic water closet seat & cover mild steel chromium plated or aluminised hinging device and connection to low level flushing cistern and flush pipe, etc complete all as specified and as directed. Use and waste form work
S&F CPVC pipe 40mm outer dia class 1 fix on wall /ceiling or laying in floor including of all fitting i.e elbow, tee and socket etc complete all as specified and as directed.
Supply and fix in repair vitreous china wash hand basin including brackets, white size 550 x 400 mm including cutting for and pinning in ends of brackets. Including waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and as directed.
S&F in repair pillar tap, brass chromium plated high neck, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nut screwed for 15mm bore iron pipe and fixed complete all as specified and as directed.
S&F PVC connection 15mm size with PTMT nuts, of 450 mm length complete all as specified and as directed.
Taking down AC/Salt glazed ware pipes and fittings upto 110mm complete all as specified and as directed.
S&F in repairs for 100mm bore dia pipe stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed.
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) bends of 75 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) junction single Tee equal or unequal 110 mm dia complete all as specified and directed.
S&F PV C (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed.
S&F PVC (SWR) floor trap, plain with grating including jointed with solvent cement of 75 mm outlet dia complete all as specified and directed.
S&F in repairs 40mm bore heavy duty waste pipe not less than 60cm long with PVC coupler for kitchen sink, WHB, urinal, etc complete all as specified and as directed.
S&F in repair stainless steel sink coupling with waste pipe complete all as specified and as directed.
S&F in repair CP steel Grating round with steel frame with hinge 100mm dia complete all as specified and as directed.
S&F in repair WPC board 18-19mm thick, medium density, flat pressed, single layer type or three layer type, BWR grade for almirah doors, self, kitchen cabinet etc complete all as specified and as directed.
S&F in repairs fancy type 5.50mm thick looking mirror with PVC moulding 40mm wide all around with back 5mm thick PVC board of size 450x600x5mm thick complete all as specified and directed.
Taking down existing roof treatment of felt etc any thickness or description including cleaning all up to roof slab including removing spoil form site and M&L for providing roof treatment as per the following steps :- (i) Filling cracks of roof slab with approved chemical sealing compound and applying 15mm thick rendering in CM 1:4 over neat cement slurry @ 3.00 Kg/Sqm over cleaned roof surface with use of approved water proofing compound.(ii) Applying a coat of cold applied bituminous primer @ 0.30 Kg/Sqm followed by APP modified five layer polymeric membrane 3mm thick, minimum weight 3.60 Kg/Sqm reinforced with polyester non-woven fabric (weight not less than 150 gms/Sqm) manufactured by laid as per the manufacturers instruction with side over lap of 75mm and end over lap of 100mm and finally finished with super silver sheild @ 0.10 Ltr/Sqm. Note :The work of water proofing treatment shall be got executed through manufacturer or authorized applicator only.
Supply only integral waterproofing compound complete all as specified and directed.
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing all as specified and directed.
M & L for point wiring complete with PVC insulated and unsheathed, Flame retardant low smoke ( FRLS ) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core in and including rigid PVC concealed conduit not less than 19 mm dia, clip, complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly complete all as specified including lugs required for One light/ceiling fan/Exhaust Fan point controlled by one switch complete all as specified and directed.
All as per item No 114 here in before but for one 5 pin 5 Amp socket outlet point on same board complete all as specified and directed.
All as per item No 114 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed.
All as per item No 114 here in before but with 2.5 Sqmm copper conductor cables (multi stranded) PVC insulated FRLS, unsheathed cable and including 2.5 Sqmm copper conductor cable (multi stranded) PVC insulated FRLS and unsheathed cable earth continuity wire to common earth and connecting to earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
S&F step type, electronic fan regulator 120 watts, 5 step for ceiling fan 1200/1400 mm sweep 230 volts AC complete all as specified and directed.
S&F switch piano flush type single pole, 5 Amps, one way complete all as specified and directed.
S&F switch piano flush type single pole, 20 Amps, one way complete all as specified and directed.
S&F socket outlet 6 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified & directed
M & L for point wiring complete with PVC insulated and unsheathed, Flame retardant low smoke ( FRLS ) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core, drawing through existing conduit (without socket, elbow, junction box, bell mouth, bend, reducer, pressed iron/steel suction box, 3 mm thick plastic laminated sheet) and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including lugs required for one light/fan point controlled by one switch, complete all as specified and directed.
All as per item No 123 here in before but point wiring for one 5 pin 5 Amp socket outlet point same board.
All as per item No 123 here in before but for one 5 pin 5 Amp socket outlet point on independent board.
All as per item No 123 here in before here in before but with 4 Sqmm copper conductor cables (multi stranded) PVC insulated FRLS, unsheathed cable and including 4 Sqmm copper conductor cable (multi stranded) PVC insulated FRLS and unsheathed cable earth continuity wire to common earth and connecting to earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
S&F modular fan regulator electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed.
S&F switch modular 6 Amps 230 Volts one way switch complete all as specified and directed.
S&F socket modular 6 Amps AC 230 Volts 2/3 pin combined 2 modular type complete all as specified and directed
S&F socket 6A/16 Amps-2/3 pin combined AC 230 Volts modular type complete all as specified and directed
S&F switch modular type AC 230 volts 16 Amps one way complete all as specified and directed
S&F modular bell push 6 Amp one module one way complete all as specified and directed
S&F GI sunken box with flush metal GI box, 2 module suitable for modular switches including plastering, making good disturbed surfaces of wall, painting to match the existing finishes complete all as specified and directed.
All as per item No 133 here in above but 3 module.
All as per item No 133 here in above but 4 module.
All as per item No 133 here in above but 6 module.
All as per item No 133 here in above but 8 module
All as per item No 133 here in above but 12 module
S&F combine cover plate white 2 module suitable for modular switches complete all as specified and directed.
All as per item No 139 here in above but 3 module
All as per item No 139 here in above but 4 module
All as per item No 139 here in above but 6 module
All as per item No 139 here in above but 8 module
All as per item No 139 here in above but 12 module.
S&F ceiling rose surface Bakelite 3 terminals of size 65x25mm complete all as specified & directed.
S&F Calling bell ding-dong complete all as specified & directed.
Fixing only LED tube light fitting 18/20 watt complete all as specified & directed. Tube light fittings shall be issued under sch ‘B’
S&F wall light fitting along with 9 Watt bulb complete all as specified & directed.
Fixing only bulk head fittings retrofit 5/9/10 watt all as specified and directed. Bulk head fittings shall be issued under sch ‘B’
Fixing only mirror light fitting 10 watt all as specified and directed. Mirror light fittings shall be issued under sch ‘B’
S&F LED Flood light fittings. die-cast aluminium housing IP66 50/60 W,6000K, 100 lumens/ watt or nearest higher size watt or higher size, fixed on pole duly fixed on angle iron bracket complete all as specified and directed. Test certificate shall be submitted by the contractor.
S&F in replacement Fans Ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. PVC AC single Phase 230 V / 240V 50 Hz of , connecting up ceiling rose to connector block of fan including fabricating and fixing of Fan hooks from ceiling truss/angle iron, required length of down rods (As per site requirement) and necessary nuts and bolts, including taking down old metallic exhaust fan complete all as specified and directed. Note : Old fan shall e deposited to MES store. Test certificate shall be submitted by the contractor.
S&F in replacement Exhaust fan exhaust fan 150 mm PVC body made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metallic exhaust fan complete all as specified and directed. Note : Old fan shall be deposited to MES store. Test certificate shall be submitted by the contractor.
S&F in replacement exhaust fan metallic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metallic exhaust fan complete all as specified and directed. Note : Old fan shall be deposited to MES store. Test certificate shall be submitted by the contractor.
S&F replacement Water heater storage type, electric, capacity 35 litres AC single phase 230/ 240 V o and connecting up including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Old geyser will deposited to MES store. Test certificate shall be submitted by the contractor.
S&F TPN DB VTPN 4 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 DB's flush mounted with 250 Amp Copper bus bar for each phase with two neutral bar & two earth bar and cable ties for cable management including mounting arrangement including DPX3 MCCB 250 Amps four pole 415 volts as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's shall hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed.
S&F sheet metal enclosure TPN for DB's when MCB's to be used 6 way with 200 amps bus bar and double door complete all as specified and directed.
S&F MCB TPN 63 Amps 10 kA, 430 Volt complete all as specified and directed.
S&F sheet metal enclosure SPN for DB's when MCB's to be used 6 way with 200 amps bus bar and double door complete all as specified and directed.
S&F metal clad single pole and neutral enclosure with 2 pin and earth plug and socket complete with and including one single pole MCB 20 Amp 240Volt complete all as specified and directed.
S&F MCB SPN 240 Volt 10 KA 6 to 40 Amp 'C' series conforming to IS complete all as specified & directed.
S&F MCB SP (single pole) 240 volt, 10 KA, 6-40 Amp, 'C' series confirming to IS complete all as specified and directed.
M&L for sub main wiring with 3 runs (P+N+Earth continuity conductor) of 2.5 Sqmm single core, PVC insulated, unsheathed, multi stranded copper conductor FRLS cable 1100 volts grade recommended colour code ,drawn through and including concealed PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting all wires with suitable size thimble complete all as specified and directed. Note:-3 runs of 2.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 163 here in above, but sub main wiring with 3 runs of 4 Sq mm wire (P+N+Earth continuity conductor) complete all as specified and directed. Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC Case & Capping shall be measured as one unit length.
All as per item No 163 here in above, but sub main wiring with 6 runs (3 run Phase +1 for Neutral +2 for Earth continuity conductor with approved colour as per EI rule) of 6 Sq mm conductor drawn through concealed conduit of size not less 32 mm dia complete all as specified and directed. Note:-6 runs of 6 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
M&L for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized iron wire 4 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/ Lt panel etc. and testing on completion, complete all as specified and directed.
Supply and Laying XLPE insulated galvanised steel strip or wire armoured electric power cable with stranded aluminium conductor 1100 V grade of size 70 sqmm 3.5 core after cutting to required length with necessary glands, nuts, bolts, and lugs complete all as specified and directed
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unserviceable LT Cable for laying of cable and getting out. complete all as specified and directed..
Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
M&L for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for GI tubing Light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 50mm dia complete all as specified and directed.
S & F microprocessor based 3 phase electronic tamper proof, static energy meter with optical communication port confirming to IS 13779 of accuracy class 1.0, 3 X 240 V, 50 Hz with Backlit LCD display of rating 10 - 60A, suitable for measurement of KWH only complete all as specified & directed. Note:- Old meter shall be deposited to MES store yard.
S&F Meter Distribution Board made out of Thermoplastic polycarbonate of size 600x600x170 mm (dust proof & weather proof ,Shock proof, rust proof, corrosion free, acid & Chemical resistance, UV resistance, Halogen free & recyclable material with 230v Ac 50 HZ 3 Wire, Gasket shall be embedded with T-locking arrangement and suitable for mounting of Electronic Meter -04 Nos including electrical connection with existing system and sealing properly & taking out unserviceable broken/rusted box of any size and type complete all as specified and directed.
V S ENTERPRISES
Avtarsinghchaddhaandcompany
AYUSH CONSTRUCTION COMPANY
M/s Pradeep Kumar
VERDHMAN ASSOCIATES
JAIN BUILDERS
ANANYA CONSTRUCTION CO.
Bhanu Prakash
M/S JAI PRAKASH GOEL
M/s Anil Kumar
Alankar Traders
M/S VIJAY TRADERS
M/S C S AITHANI
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .