EXECUTIVE ENGINEER, G.I.D.C. MEHSANA,
Upgradation of basic infrastructure facilities like Road, Storm water drain, Street Light etc. at PATAN Industrial Estate.
360293
Tender notice No.07 of 2026-2027
Open
Civil Works
Works
Mehsana
3 documents required · 3 mandatory
₹7,080
Executive Engineer GIDC Mehsana
₹4.7 L
28 Oct 2026
28 Oct 2026
28 Oct 2026
23 Nov 2026
28 Oct 2026
120 days
Name of work: Upgradation of basic infrastructure facilities like Road,
Storm water drain, Street Light etc. at Patan Industrial
PRICE BID / SCHEDULE-B
Item Item Description Qty. Unit Rate Amount
Part-1 STORM WATER DRAIN WORK
1 Excavation for foundation upto 1.5 2,540.00 Cum 157.08
m depth including dismantling the
existing structure RCC/Bitumines
Surface, hume pipes etc sorting
out and stacking of useful
materials and disposing off the
excavated stuff within /out side
state as per direction of engineer in
charge. all disposal must be done
as per govt./GPCB guidelines. (B)
Dense or Hard soil.
2 Providing, supplying and fixing in 1,689.00 Rmt 10,673.68
position with proper Jointing , the
Precast U shape RCC Drain T-6 of
0.9 m width x 0.9 m depth
excluding lid, made of M-50 grade
of concrete with Reinforcement
TMT Fe 500 D as per by wet
Casting method with necessary cut
out in the wall for pipe connection.
The rates shall be including
mm thick PCC in M 15 for
foundation, Loading &
Transportation to site, unloading,
placing, jointing etc. but excluding
the cost of necessary excavation as
directed by engineer in charge.
3 Providing, supplying and fixing in 89.00 Rmt 18,594.10
position with proper Jointing , the
Precast U shape RCC Drain T-25 of
0.9 m width x 0.9 m depth with lid
, made of M-50 grade of concrete
with Reinforcement TMT Fe 500 D
as per by wet Casting method with
necessary cut out in the wall for
pipe connection. The rates shall be
including 100 mm thick PCC in M
15 for foundation, Loading &
Item Item Description Qty. Unit Rate Amount
Transportation to site, unloading,
placing, jointing etc. but excluding
the cost of necessary excavation as
directed by engineer in charge.
4 Providing fixing in position with 20.00 No. 34,216.78
proper Jointing , the Precast RCC
box Chamber with solid cover of
clear section size , made of M-50
grade of concrete with
Reinforcement TMT Fe 500 D as
per by wet Casting method with
necessary cut out in the wall for
pipe connection. The rates shall be
including the cost of necessary
excavation, 100 mm thick PCC in M
15 for foundation & 100 mm thick
as bottom , Loading &
Transportation to site, unloading,
placing, pipe jointing etc but
excluding the cost of necessary
excavation as directed by engineer
5 Filling available excavated earth 730.00 Cum 136.92
(excluding rock) in trenches. plinth,
sides of foundations etc. in layers
not exceeding 20 cm. in depth
consolidating each disposited layer
by ramming and watering.
Part-2 PATAN GIDC ROAD WORK
1 Box cutting the road surface to 7,890.00 Cum. 114.44
proper slope and camber for
making a base for road work
including dismantling the existing
structure removing the excavated
stuff and dispositing as directed up
to any meter lead.
2 Construction of Subgrade with 3,760.00 Cum. 357.01
approved material obtained from
borrow pits with all lifts and leads,
transporting to site spreading,
grading to required slope and
compacting to meet requirement
to MoRTH table 300-2 in layers not
Item Item Description Qty. Unit Rate Amount
more than 200 mm thick as
directed by engineer in charge.
(Effective CBR Minimum 8%).
3 Providing and laying 150 mm thick 1,080.00 Cum. 1,792.00
Granular sub-base in one layer by
providing ( Grade-V) , Crushed B T
materials of 53 mm to 26.5 mm @
) having C.B.R. not less than 30%,
as per table 400-1 of MORTH
gradation including leveling the
material at site of work ,mixing and
spreading into grade and camber
watering and consolidation at
OMC with Vibratory roller
including cost of material, labour
4 Construction of dry lean cement 1,080.00 Cum 2,952.65
concrete Sub- base over a
prepared sub-grade with coarse
and fine aggregate conforming to
IS: 383, the size of coarse
aggregate not exceeding 25 mm,
aggregate cement ratio not to
exceed 15:1, aggregate gradation
after blending to be as per table
600-1, cement content not to be
less than 150 kg/ cum, optimum
moisture content to be
determined during trial length
construction, concrete strength
not to be less than 10 Mpa at
days, mixed in a batching plant,
transported to site, laid with a
paver with electronic sensor,
compacting with 8-10 tonnes
vibratory roller, finishing and
Item Item Description Qty. Unit Rate Amount
5 Cement Concrete Pavement M: 40 1,800.00 Cum 7,099.62
Construction of un-reinforced,
dowel jointed, plain cement
concrete pavement over a
prepared sub base with approve
grade cement @ 400 kg per cum,
coarse and fine aggregate
conforming to IS 383, maximum
size of coarse aggregate not
exceeding 25 mm, mixed in a
batching and mixing plant as per
approved mix design, transported
to site, laid with a fixed form or slip
form paver, spread, compacted
and finished in a continuous
operation including provision of
contraction, expansion,
construction and longitudinal
joints, joint filler, separation
membrane, sealant primer, joint
sealant, debonding strip, dowel
bar, tie rod, admixtures as
approved, curing compound,
finishing to lines and grades as per
6 Road marking with hot applied 379.00 Sqm 367.72
thermoplastic paints with
reflectorising glass beads on
bitumen surface providing and
laying a hot applied thermoplastic
compound 2.5mm thick including
reflectorising glass beads @
250gms per sqm area, thickness of
2.5mm is excluding of surface
applied glass beds as per IRC:35-
2015. The finished surface to be
level, uniform and free from
streaks and holes. zebra patta
/bump patta lane /center line
/edge line /cut patta. The white
colour marking should provide
liminance coefficient on cement
road shall be min 130 mcd/m2/lux
and Asphalt road shall be
min100mcd/m2/lux during the
Item Item Description Qty. Unit Rate Amount
service life during the day time.
The marking should meet the
performance criteria for night time
reflectivity, wet reflectivity and
skid resistance as mentioned in the
section-15 of IRC35 (Latest
Revision). Warranty for the Retro
reflectivity should be two years.
7 Cat Eye / Road Stud / RPM: 316.00 No. 326.23
Supplying of Molded Twin Shanks
Raised Pavement Markers made of
polycarbonate and ABS moulded
body and reflective panels with
micro prismatic lens capable of
providing total internal reflection
of the light entering the lens face
and shall support a load of
kgs. tested in accordance to ASTM
D 4280 Type H and complying to
Specifications of Category A of
MORTH Circular No
RW/NH/33023/10-97 DO III Dt
11.06. 1997. The height, width and
length shall not exceed 20 mm,
mm and 130 mm and with
minimum reflective area of
Sqcm on each side and the slope to
the base shall be 35 +/- 5 degree.
The strength of detachment of the
integrated cylindrical shanks, (of
diameter not less than 19 +/- 2 mm
and height not less than 30+/-
mm) from the body is to be a
minimum value of 500 Kgf. Fixing
will be by drilling holes on the road
for the shanks to go inside, without
nails and using epoxy resin based
adhesive as per manufacturers
recommendation and The colour
of the marker should be as per the
IRC 35 (Latest Revision) and as
directed by Engineer-in-charge.
Item Item Description Qty. Unit Rate Amount
Part-3 FOOTPATH WORK / GREEN AREA
1 Box cutting the road surface to 2,210.00 Cum. 109.05
proper slope and camber for
making a base for road work
including removing the excavated
stuff and dispositing as directed up
to any meter lead.
2 Construction of Subgrade with 1,499.00 Cum. 357.01
approved material obtained from
borrow pits with all lifts and leads,
transporting to site spreading,
grading to required slope and
compacting to meet requirement
to MoRTH table 300-2 in layers not
more than 200 mm thick as
directed by engineer in charge.
(Effective CBR Minimum 8%).
3 Providing and laying 150 mm thick 440.00 Cum. 1,792.00
Granular sub-base in one layer by
providing ( Grade-V) , Crushed B T
materials of 53 mm to 26.5 mm @
) having C.B.R. not less than 30%,
as per table 400-1 of MORTH
gradation including leveling the
material at site of work ,mixing and
spreading into grade and camber
watering and consolidation at
OMC with Vibratory roller
including cost of material, labour
4 Providing and fixing pre-cast 1,760.00 Sqm 701.14
Rubber Dye / steel Dye inter
locking concrete block 60mm thick
with grade of concrete M350
pnumatic compressed / vibrated
mechanically and as per approved
design Confirming to IS 15658 :
2006 including 35 mm Sand layer
for levelling and filling the joint
with sand in proper line and level
as per guidlines of IRC : SP 63-2018
Item Item Description Qty. Unit Rate Amount
5 Providing and filling in foundation 50.00 Cum. 3,149.40
with ordinary Cement concrete M-
100 mix and providing necessary
vertical pin headers including
formwork, vibrating, ramming and
curing complete.
6 Providing and fixing pre-cast 1,780.00 Rmt 374.92
concrete kerb stone of gray
cement based concrete block
30cm length, 30cm height and
15cm thick of M250 grade concret
as per approved design and
including excavation for fixing in
proper line and level,filling the
joint with C:M 1:3 (1cement:3fine
sand) etc complete.
7 Construction of embankment with 100.00 Cum. 333.54
approved material obtained from
borrow pits with all lifts and leads,
transporting to site spreading,
grading to required slope and
compacting to meet requirement
to MoRTH table 300-2.in layers not
more than 200 mm thick as
directed by engineer in charge.
Part-4 Street Light work
1 Supplying and erecting approved 46.00 No. 12,553.29
make Octagonal pole made from
HR sheet steel. The pole should be
made as per IS. and shall be coated
with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend
local wind speed with integral
Junction box consist of terminal
plate of min 6mm Hylam sheet,
standard profile 35mmX7.5mm
Din-Rail for MCB Mounting, stud
type terminal and arrangement for
cable termination to be erected
With Suitable foundation
(Included) as per details given by
manufacturer considering site
requirement to be erected on
suitable foundation as per detils
Item Item Description Qty. Unit Rate Amount
given by manufacturer considering
site requirment. (E) 7 Mtr. Long
mm Top X 135 mm bottom dia,
mm thickness with
225mmX225mmX16mm base
plate, 4-M20 Bolts and 600mm
long J-Bolt EN 8 grade HDG
foundation bolts along with
template for the above poles with
"GIDC" Logo on Name
Plate.Approx Pole weight 67 kg
2 Providing & Fixing of Solderless 384.00 No. 13.13
Crimping Type Aluminium Lugs (4
Nos. per termination) conforming
to IS suitable for 1 x 4.0 Core x
Sq. MM PVC Insulated Aluminium
Armoured cable evenly crimped
with high pressure tool &
connected to switchgear terminals
with brass/cadmium plated nut
bolts in an approved manner. - (4
Nos. Termination X 2 = 8 nos. Per
St. Light Pole & 16 nos. per panel)
3 Providing & erecting 240 V MCB 46.00 No. 306.03
double pole switch for lighting
Load (B Curve) having 10 KA
breaking capacity & confirms to IS :
8828 in existing box having
following capacity.(A) 6 to 32 Amp.
Cat.III - (1 No. Per St. Lght Pole)
4 Providing and erecting Funnel Pipe 46.00 Job 618.12
type earthing having 150 cms.long
and 2.5 cms. dia. galvanised iron
pipe with coupling and buch buried
in specially prepared earth pit
complete with necessary 8 SWG
earth wire and required size HOT
deep Galvanised iron strip for
earthing of Street light pole using
proper clamp with using salt and
charcoal / coke as required for pipe
type earthing. (1 Job Per St. Light
Item Item Description Qty. Unit Rate Amount
5 Providing and erecting Street Light 46.00 No. 683.77
pole bracket comprising main B
Class GI pipe of 4.2 cm/require
outside dia. complete with suitable
B Class G.I. sleeve tubing of approx.
45cms.length and suitable for
mm /80mm / required size of pole
top having sufficient fasteners for
fixing the brackets and having
spread of 1.5.mtr. length with
deg.with vertical plane & suitable
welded stays, reducer and with
check nuts complete painted with
one coat of Red oxide / PU base
primer and two coats of Aluminium
/ PU paint. paint with following nos
of arms. [A] Single Arm Bracket
Mtr (1 No. Per St. Light Pole)
6 Supplying and erecting 90 Watt 46.00 No. 5,581.26
LED street light fittings with fixed
programmeable micro processor
based dimmable drive , High power
White LEDs wattage of 3 Watt and
above assembled on single MCPCB,
efficiency more than 130 lm/w and
corrosion free High pressure die
cast aluminum housing with
smooth finish powder coated and
heat sink extruded aluminium with
diffuser and Polycarbonate optics/
lenses with company mark/name
engraved or embossed 120 to
V,Power Factor more than 0.95,
THD < 10 %, CCT 5000 K to
5700K,Uniformity ratio >0.45,
Luminaire efficacy>
lumens/watt . LED driver efficiency
> 85 %.CREE / OSRAM / PHILIPS
Lumileds / NICHIA / SEOUL/
LG/BridgeLux (U.S.A.) make LED
used for luminaire. ( Fittings
required LM-79 & LM-80
certificates)-(A) Street Light (IP-
66), Surge Protection -4KV and
KV non integral, Light must have
Item Item Description Qty. Unit Rate Amount
440VAC line supply protection. It
should withstand 48 hours for
440VAC line supply.(Cat-III)
7 Supplying and erecting Flexible FR 414.00 Mtr 97.97
PVC insulated multi strand multi
core 1.1 kV grade ISI Marked
Copper wires of 2.5 Sq. MM.,3 core
round PVC sheathed in exising
pipe/ in street light pole erected
with green colour for earth
8 Providing & erecting of 1 x 4.0 Core 1,610.00 Mtr 168.67
x 10 Sq. MM, XLPE (IS: 7098 (i) - 88),
ISI Mark, Armoured cable,
Multistranded Aluminium
Conductor suitable for 1.1 kV grade
to be laid on wall with necessary
clamps or to be laid 90 Cms
underground in existing cable
trench/ pipe at road crossing or on
floor and making the ground as per
original. - For Streetlight between
two poles & Service
Connections.(Considering 25 Mtr.
Distance between two poles and
extra cable for loop = 35 Mtr.)
9 Providing & laying of approved 1,380.00 Mtr 62.62
make 50 MM outer dia Doubled
Walled Corrugated Pipes (DWC) of
polyethylene (conforming to IS
14930 - II) with necessary
connecting accessories like
coupler, Tee, L - Bow, etc. of same
material at required depth (90
cms) for laying of cable below
ground/ road surface for enclosing
cable and back filling the same to
make ground as per original & as
per instruction of Engineer
Incharge - for Streelight Cable of
x 4 core x 10 Sq. MM. (30 Mtr Per
Between two Pole)
Item Item Description Qty. Unit Rate Amount
10 Providing & laying of approved 114.00 Mtr 95.95
make 90 MM outer dia Doubled
Walled Corrugated Pipes (DWC) of
polyethylene (conforming to IS
14930 - II) with necessary
connecting accessories like
coupler, Tee, L - Bow, etc. of same
material at required depth (90
cms) including excavation for
laying of cable below ground/ road
surface for enclosing cable and
back filling the same to make
ground as per original & as per
instruction of Engineer Incharge -
for Streelight Cable of 1 x 4 core x
11 Drilling the road without breaking 114.00 Mtr 492.88
the road surface (Asphalt) for
laying of cable for feeding power
supply by making up to 100mm
dia.size of holes at both ends
12 Making trench in soft soil of 1,380.00 Mtr 55.55
suitable width of 90 cm deep for
laying cable or locating the fault all
over the run and back filling the
same and making the surface as
13 Painting the number and words for 47.00 No. 22.22
inventory Identification on erected
fittings / equipment’s or Such
accessories as may required with
good quality of enamelled paint as
directed by engineer in charge(i)
up to 20 characters, up to 50 mm
Item Item Description Qty. Unit Rate Amount
14 Smart 4G Timer, Supply of IoT 1.00 No. 1,00,427.33
based 4G Smart Streetlight Control
& Monitoring System having a
Smart Panel comprising of 3 Phase
IoT Streetlight Smart 4G Timer with
16x2 LCD to display RSSI, relay
status, RTC time & diagnostics.,
Controller works on 3-phase & also
on any available 1-Phase.,
Controller with 8-hour battery
backup during external power
failure. External power failure alert
immediately to cloud., 110-630 V
AC @ 50-60 Hz – 3 phase operating
range., Standby power
consumption <3W., Smart 4G
Timer with RS232 port for DLMS
Energy meter., Smart 4G Timer
must be compatible with any make
/ brand of DLMS (RS232) Energy
Meter., DI: 4 Nos. (3 Contactor /
Latch detection, 1 for Door
Sensor.)., DO: 3 Relays for
Independent control each phase
(R, Y, B) with 1 extra spare relay.,
Smart 4G Timer with dual SIM
functionality for connectivity
backup., 4G M2M SIM 3-Year
communication included., Local
configuration via WiFi / BLE for
maintenance or during force
majeure., GPS chip inbuilt of Smart
4G Timer for auto location tracking
& astronomic schedule location.,
50 programmable schedules.,
Astronomic scheduling with
monthly offsets., Smart 4G Timer
has inbuilt timer stores schedules
locally & also stores schedule
execution logs locally, syncs to
cloud whenever connected to
cloud., Auto-scheduler overrides
manual operations., Monitoring &
alerts for MCB trips., Over/under
voltage, current, overload, power
Item Item Description Qty. Unit Rate Amount
factor & short circuit protections
with alerts via Dashboard, App,
SMS, WhatsApp & Email.,
Contactor / Latch chattering
protection & alerts., Smart 4G
Timer with neutral failure
protection and alert., Bulit-in
Watchdog for anti-jamming.,
Smart 4G Timer must send Regular
"heartbeat" on software for CCMS
15 Providing & erecting Approved 1.00 No. 6,790.23
make Four pole moulded case
circuit breaker having breaking
capacity ICU of 25 KA. at
V,having normal current rating up
to 25 A to 100A. with Fixed thermal
& magnetic release suitable to
work on A.C. supply 50 c/s. with all
internal connections & complete
erected in existing 16 G.M.S.
housing. (Cat - III) suitable to work
on AC supply with all internal
connection-ICS=100% of ICU only.
16 Providing & Fixing of Heavy Duty 2.00 No. 38.38
Flange type Double Compression
brass double Compression type
Cable Gland with rubber ring
suitable for 1 x 4.0 Core x 10 Sq.
MM PVC Insulated Alu. Armoured
cable complete with outgoing tails,
insulating taps etc.
Item Item Description Qty. Unit Rate Amount
17 Supplying & erecting in earthpit of 1.00 No. 8,636.51
minimum bore dia. 150mm size
approved make Earthing Electrode
consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50 mm
having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having
200-250 Micron galvanising,
connection terminal dia of 12 mm
with constant ohmic value
surrounded by highly conductive
compound with high charge
dissipation suitable for following
type of applications with chamber
and heavy duty cover.(approved
make OEM has to submit test
certificate including value of earth
resistane of installation.) & having
back filling compound of (B) Inner
Chemical (CCm Compound) -
Resistivity :- 0.2 Ohm/meter
testing as per IEC 62561-2017
Voltage Drop :- < 1 volt at no load
& dry form , Sulpher content :- <2%
.(C) Back filling copound :- Earthing
compound should be capable to
retain moisture for log time.
Necessary test report must be
submitted. (C) For Electrical
Installation covering Transformer
Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive
Computer System (like
Automation, SCADA) i.e.
independent Earthing located in
other than normal soil i.e. Soft
Rock, Marshy Soil etc..-Length of
Pipe : 3 Mtrs. -Back filling
Compound :2 nos Bags of 25 Kg.-
(1 Job per Distribution Box)
Item Item Description Qty. Unit Rate Amount
18 Annual Operation charge: Agency 60.00 46 3,284.86
has to carry out operation of the Fitting/Month
streetlight network with necessary
manpower and material during
the year , in such a way that
through all year,streetlight
network will run with minimum
95% efficiency. The job also
includes liaison with UGVCL
Officials at the time of any fault
occurred to restore the power at
the earliest. The agency has to
carry out the work as per direction
of Engineer in charge and / or as
specified in the detailed scope of
work. Efficiency of the street light
shall be checked on weekly basis &
agency has to attend the site
during weekly checking of street
light & all fittings. Agency has to
arrange the vehicle for the
engineer i.e. Car/ Bike or rickshaw
as & when required or called for
Patan GIDC I.E. Total Nos. of Street
Light Pole = 46 Nos. (90W LED
Fitting). So, Total 46.0 Nos St. Light
Rs./Fitting/Month = Rs.
Grand Total : Rs.
Grand Total : Rs.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Technical bid Patan.pdf
2. PQ Patan.pdf
3. Item wise specification Civil.pdf
4. Item Specifications for Street Light_Patan.pdf
5. Price Bid Patan.pdf
B1 Agrrement - Part 1.pdf
B1 Agrrement - Part 2.pdf
Patan Revise Appendix A Definition of similar work.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .