GE(KH)YOL
GE(KH)YOL
COMPREHENSIVE MAINTENANCE OF E/M INSTALLATION UNDER AGE E/M YOL CANTT
2020_MES_405104_1
GEY-61/2020-21
Open Tender
Civil Works
Item Rate
183 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(KH)YOL
₹20,000
Yes
19 Feb 2021
19 Dec 2020
16 Jan 2021
19 Dec 2020
14 Jan 2021
2 Jan 2021
60 days
Amount
Acrylic sheet, 4 mm thick including vinyl printing and fixing at site with suitable means on the plant/ installations all as specified and directed.( Subject of printing shall be provided by the Eng-in-charge )
Shifting of transformer, trolly mounted of capacity upto 400 KVA from one station to other (situated at a distance not exceeding one kilometre) carefully with the help of tractor/ crane including all towing arrangements and taking out HT/ LT connections, earthing of defective transformer and connecting carefully HT/ LT connections including temporary earthing all as specified and directed.
Disconnecting of all incoming and out going cable connections, earthing from the transformer, removing of transformer from position for repair of plinth base complete and reinstalling the same after servicing and necessary repairs and reconnecting of all incoming and outgoing electric cables and earthings upto 400 KVA from the sub station carefully with the help of crane/ chainpully all as specified and directed.
Pin type porcelain vitreous white brow or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade, complete all as specified ,including taking down old insulators of any type, shape and size, all as specified.
Shackle type insulator porcelain vitreous white, brown or green 75mm high and 90mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31x3mm size, 12mm dia insulator bolts, washers and nuts , complete all as specified including taking down old insulators of any type, shape and size, all as specified.
Dismantling/ taking out old unserviceable cable of any size and removing from site, complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 2 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
Excavation in trenches for cable and poles in any type of soil n.exc 1.5m wide and not exc 1.50metre deep and getting out complete all as specified and directed.
Excavation in trenches for cable and poles in any type of soil n.exc 1.5m wide and but exc 1.5 metre deep and not exc 3.00 metre deep and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5metres above the starting point complete all as specified and directed.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of reinforced cement concrete M-15, reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to and including galvanised iron strip 25mm X 4mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of GI and GI strip protected by provision of GI pipe light grade, 40mm bore upto test point including provn of concrete pit in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of reinforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metres long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron strip 25mm X 4mm size and protection pipe of 40 mm bore galvanised iron light grade and earth work.
Plain cement concrete M-7.5 nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundation of poles, stays etc. as mass concrete, complete all as specified.
Plain cement concrete M-10 nominal mix, type C-1 using 20mm graded crushed stone aggregate as in coping of pole including necessary form work , complete all as specified.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC including dismantling of old type of poles any length , complete all as specified and directed. Note : Excavation & earth work and PCC shall be measrued and paid separately.
Painting to existing steel tubular LT poles, 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
Painting to existing Prestressed concrete poles, 8.5m long with two coats of cement base paint including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
Re-stretching of ACSR conductor and earth wire of any size and type on HT/ LT poles including disconnecting and re-binding with insulators with suitable size of binding wire after re-stretching, connecting jumpers, adjusting line dividers etc complete all as specified and directed. (Each line to be measured)
Triming of tree branches after taking shut down from power house, 1.0 metre apart from HT/LT line carefully and considering the span from pole to pole, complete with cleaing the whole area grabbed by the the trimed branches of tree, complete all as specified.
Supply & fix three pole power contractor, 415 Volts ML-4, Conforms to IS/IEC60947-4-1 & IEC 60947-4-1, Rating 70A for AC-3 & 100A for AC-1, I Robust and suitable for hostile applications for street light control including electric connection complete all as specified & directed including taking down old one.
Supply & fix street light timer FM1/Quartz Daily 240V AC Base/DIN Mounting analogue type suitable for street light control complete all as specified & directed including taking down old one.
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 65x90mm clearance of hole 16mm, including taking down existing unserviceable complete all as specified
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 65x90mm clearance of hole 16mm, including taking down existing unserviceable complete all as specified
MCCB 3 pole with fixed thermal and fixed magnectic release, 160 Amps having rupturing capacity 16 KA all as specified and directed.
MCCB 3 pole with adjustable thermal and fixed magnectic release, 250 Amps having rupturing capacity 35 KA all as specified and directed.
PVC seperator suitable for four ACSR Conductor feeder, complete all as specified.
M&L for wiring with two runs of 2.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed copper conductor FRLS cable upto and including 1100 V grade drawn through PVC rigid conduit medium grade fixed to wall / ceiling / pole etc including one run of 2.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed copper conductor FRLS cable as earth wire and duly connected to common earth point including necessary clamps all as specified and directed including taking down old unserviceable sub main wiring . (Note :-(i) One Run of PVC rigid conduit with all fittings/accessories, Two runs of 2.5 sqmm single core cable and one run of 2.5 sqmm earth continuity wire to be measured as one Running metre).
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm, including taking down old wire complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 16 sqmm, including taking down old wire complete all as specified.
surinder kumar jindal & bros.
M/S VIG AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .