Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹9.0 L+₹22,550 (2.56%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹9.1 L+₹24,880 (2.82%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹9.3 L+₹52,689 (5.98%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | L5₹9.9 L+₹1.1 L (12.2%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
9 Dec 2021, 6:00 pmClosed
GE (AF) Phalodi
GE (AF) Phalodi
REPAIRS OF SERVO VOLTAGE STABILIZER, APFC PANEL AND CONNECTED ITEMS AT AF STN PHALODI
2021_MES_488043_1
8363/A/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Phalodi
Class E Cat b(i)
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹30,000
Yes
22 Jan 2022
12 Nov 2021
11 Dec 2021
12 Nov 2021
9 Dec 2021
26 Nov 2021
Amount
Repair of existing automatic / manual type APFC panel cleaning of dust inside the panel from electric blower cleaning of contractor relay ,junction point/ connection sevicing overhouling of cooling fan complete testing of APFC relay including necessary setting with CT load adjustment to match of 50 KVAR to 500 KVAR to set the power facter in range between 0 .96 to 0 .99 complete all as per specified and directed. NOTE -(a) Replacement of u /s item with are covered under respective item of schedule will be measured & paid separetely . (b) Replacement of minor item /spares shall deemed in to the quoted rate
S&F in repairs of contactor capacitor duty type 3 pole AC of capacity having coil voltage 250 volt up to suitable for 20 KVAR alonge with 1 NO + 1 NC auxilary contact complete all as per specified and directed.
S &F in repairs of contactor capaciter duty type 3 pole AC of capacity having coil voltage 250 volt up to suitable 25 KVAR alonge with 1 NO + 1NC auxilary contact complete all as per specified and directed.
S&F in repairs of APFC /AIPFC relay source type with protection device intelligent automatic processor has on power controller unit up to 8 stage complete all as per specified and directed.
All as per item No. 4 above but 12 stage.
S &F in repairs of capacitor 3 phase 440 volt 50 HZ & APP type electric to ISS 13340 /13341 to ICC 9311 complete of capacity 5 KVAR ( bottle type ) gas filled complete all as per specified and directed.
All as per item No. 6 above but 10 KVAR
All as per item No. 6 above but 12.5 KVAR
All as per item No. 6 above but 15 KVAR
All as per item No. 6 above but 25 KVAR
S &F in repairs of volt meter 0 -500 volt digital type square 96 sq mm lamp accurracy glass -1 complete all as per specified and directed.
S &F in repairs of Ammeter 0 -200 Amp digital type square 96 sq mm lamp accurracy glass -1 complete all as per specified and directed.
S &F in repairs of C T coil suitable for Amp meter 100 /5 Amp complete all as per specified and directed.
S &F in repairs of indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type complete to match existing one complete all as per specified and directed.
M & L for main incoming Single Core FR Round PVC Insulated Industrial Grade Copper Conductor 10 SQMM (Unsheathed) Flexible Cables, 1100 Volts,conforming to IS: 694 complete all as per specified and directed.
S &F in repairs MCB SP 10 KA C curve type of capacity 06 to 10 Amp complete all as per specified and directed.
S&F in repairs isolator TP 415 volt 10 KA C curve type of capacity 100 Amps complete all as per specified and directed.
S&F in repairs Isolator TP 415 volt 10 KA C curve type of capacity 63 Amps complete all as per specified and directed.
S&F in repairs Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 630 Amps, 50 KA rating,Ics=75% Icu ,415 volts AC complete all as per specified and directed.
S&F in repairs Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 400 Amps, 36 KA rating,Ics=75% Icu ,415 volts AC complete all as per specified and directed.
Supply and fix in repair Togal Switch suitable for 3 Phase Voltage Stabilizer complete all as per specified and directed.
Shifting after disconnecting/dismantling primary & secondary connection carefully of servo voltage stablizer out door/indoor type complete of capacity 50 KVA to 300 KVA from its foundation and safely shifting one place to another place where directed by Engr-in-charge and reconnection of cabling ,earthing ,install testing and commissoning of the servo voltage stablizer complete all as per specified and directed. Note:- Cost of Necessary tools and plants such as Vehicle, hydra/Crane etc should be deemed to be included in the unit rate quoted.
M&L painting of servo stabilizer extrenally spray painting with synthetic enamel paint of grey colour after cleaning surface throughtly with thinner and scrapper and preparing the surface to required standard including writing and making such as MES No on the body of servo stabilizer of caapacity upto 75 KVa complete all as per specified and directed.
M&L painting of servo stabilizer extrenally spray painting with synthetic enamel paint of grey colour after cleaning surface throughtly with thinner and scrapper and preparing the surface to required standard including writing and making such as MES No on the body of servo stabilizer of caapacity 100 KVA to 300 KVA complete all as per specified and directed.
Complete servicing of working/non working existing servo voltage stabilizer automatic operation three phase of various makes & capacity exceeding 16 KVA but not exceeding 75 KVA at different locations by dismantling / opening the stabilizer for checking the parts/components, circuit for proper functioning, cleaning inside the stabilizer, replacement of defective minor items i,e. screws, lugs, cut out/fuses etc. Reassembling the stabilizer, testing on rated equipment load for automatic operation to stabilizer standard out put voltage, complete all as per specified and directed. Note:- (i) Cost of Necessary tools and plants such as Vehicle, hydra/Crane etc should be deemed to be included in the unit rate quoted. (ii) Any spare part of stabilizer if found defective will be measured as supply and fix in repairs under respective item of this Sch.
All as per item No. 25 above but capacity exceeding 100 KVA but not exceeding 300 KVA
S & F in repairs of push butten switch as per existing Make and suitable for servo stabilizer of capacity upto 300 KVA complete all as specified and directed.
S & F in repairs of Auto manual switch as per existing Make and suitable for servo stabilizer of capacity upto 300 KVA complete all as specified and directed.
S & F in repairs of Micro switch as per existing Make and suitable for servo stabilizer of capacity upto 300 KVA complete all as specified and directed.
S & F in repairs of PCB holder as per existing Make and suitable for servo stabilizer of capacity upto 300 KVA complete all as specified and directed.
S & F in repairs of Carbon bush as per existing Make and suitable for servo stabilizer of capacity upto 300 KVA complete all as specified and directed.
S & F in repairs of Carbon bush holder as per existing Make and suitable for servo stabilizer of capacity upto 300 KVA complete all as specified and directed.
S & F in repairs of Trigger transformer as per existing Make and suitable for servo stabilizer of capacity upto 300 KVA complete all as specified and directed.
S & F in repairs of Shunt coil, 220 Volt, AC, as per existing Make and suitable for servo stabilizer of capacity upto 300 KVA complete all as specified and directed.
Supply and fix in repair electronic circuit card (PCB) suitable for automatic three phase stabilizer 16 KVA and 40/50 KVA capacity of various make with high & low voltage cutout device but excluding ICS, complete all as per specified and directed.
All as per item No.36 above but for 40 KVA to 75 KVA
All as per item No.36 above but for 100 KVA
All as per item No.36 above but for 150/160 KVA
All as per item No.36 above but for 200 KVA to 300 Kva
Supply and fixing in repair Servo motor with RC net work 10Kg Suitable for 3 Phase Voltage Stabilizer ,20 to 40 KVA, 415 V, 50 Hz, complete all as per specified and directed.
Supply and fixing in repair Servo motor with RC net work 3Kg Suitable for 3 Phase Voltage Stabilizer ,50 to 75 KVA, 415 V, 50 Hz, complete all as per specified and directed.
Supply and fixing in repair Servo motor with RC net work 10Kg Suitable for 3 Phase Voltage Stabilizer ,100 to 150 KVA, 415 V, 50 Hz, complete all as per specified and directed.
Supply and fixing in repair Servo motor with RC net work 10Kg Suitable for 3 Phase Voltage Stabilizer ,200 to 300 KVA, 415 V, 50 Hz, complete all as per specified and directed.
Supply and fixing in repair Control circuit Low/high Cut off with relay suitable for 3 Phase Voltage Stabilizer ,40 to 60 KVA, 415 V, 50 Hz, complete all as per specified and directed.
Supply and fixing in repair Control circuit Low/high Cut off with relay suitable for 3 Phase Voltage Stabilizer ,75 to 300 KVA, 415 V, 50 Hz, complete all as per specified and directed.
M&L in repair Gas Ket Sets suitable for 3 Phase Voltage Stabilizer complete all as per specified and directed.
S&F in repair gear and driver assembly capacity exceeding 50 KVA but not exceeding 100 KVA per phase of servo vloltage stabilizer complete all as per specified and directed.
S&F in repair gear and driver assembly capacity exceeding 100 KVA but not exceeding 300 KVA per phase of servo vloltage stabilizer complete all as per specified and directed.
M&L in repair Main Boosting TR rewinding (Copper winding heavy duty) Suitable for 3 Phase Voltage Stabilizer 50 to 150 KVA,415 V,50 Hz, complete all as per specified and directed.
M&L in repair Main Boosting TR rewinding (Copper winding heavy duty) Suitable for 3 Phase Voltage Stabilizer ,200 to 300 KVA, 415 V, 50 Hz, complete all as per specified and directed.
M&L in repair Dimmer (variac) rewinding with Copper winding Suitable for 3 Phase Voltage Stabilizer ,50 to 150 KVA, 415 V, 50 Hz, complete all as per specified and directed.
M&L in repair Dimmer (variac) rewinding with Copper winding Suitable for 3 Phase Voltage Stabilizer ,200 to 300 KVA, 415 V, 50 Hz, complete all as per specified and directed.
star electricals
L C ASSOCIATES
M/S SOLANKI GENERAL SUPPLIERS
SANJOLI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .