| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC 56 C 2 BIDHANNAGAR ROAD KOLKATA WEST BENGAL 700067 | KOLKATA | KOLKATA | WEST BENGAL | 700067 | L1 | Accepted-AOC AOC | |
| 2 | L2₹6.8 L+₹35,208 (5.44%)Rejected-Finance SANYAL PARA ROAD HARANAVI KOLKATA 700 148 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700148 | L2 | Rejected-Finance L2 | |
| 3 | L3₹8.0 L+₹1.5 L (23.3%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹8.1 L+₹1.6 L (24.8%)Rejected-Finance DUCKBANGLO JAGADISHPUR RAJARHAT NORTH 24 PGS KOLKATA 700135 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700135 | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | FAIRWAY ENTERPRISE L2 | BANERJEE ENTERPRISE L1 | RIDDHI (INDIA) L4 | ELECTROTECH L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of different existing El units (Old Tubelight fittings, Old TubeLight, downrod, Old Wires, etc.) as required and mending good the damages as per direction of EIC. | 1 | Job | 1,580 ₹1,580 | 1,162 ₹1,162 | 108 ₹108 Lowest | 2,500 ₹2,500 |
| 2.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (Make: Polycab/KEI/Finolex/Havells)
3 x 22/0.3 (1.5 sqmm) | 300 | Mtr | 95 ₹28,500 | 79 ₹23,700 | 99 ₹29,700 | 75 ₹22,500 Lowest |
| 2.01 | 2x(2.5 sqmm)+1x(1.5 sqmm) | 180 | Mtr | 105 ₹18,900 | 92 ₹16,560 | 117 ₹21,060 | 85 ₹15,300 Lowest |
| 2.02 | 2x(4 sqmm) + 1x(2.5 sqmm) | 180 | Mtr | 116 ₹20,880 | 115 ₹20,700 | 135 ₹24,300 | 105 ₹18,900 Lowest |
| 3.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm) | 90 | Mtr | 50 ₹4,500 | 37 ₹3,330 Lowest | 63 ₹5,670 | 85 ₹7,650 |
| 3.01 | 2x(2.5 sqmm)+1x(1.5 sqmm) | 200 | Mtr | 57 ₹11,400 | 50 ₹10,000 Lowest | 99 ₹19,800 | 95 ₹19,000 |
| 3.02 | 2x(4 sqmm) + 1x(2.5 sqmm) | 180 | Mtr | 87 ₹15,660 | 73 ₹13,140 Lowest | 127 ₹22,860 | 105 ₹18,900 |
| 4.00 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19/25 mm, 3 mm thick Polythene pipe as per GS. 19 mm dia 3 mm thick | 150 | Mtr | 60 ₹9,000 | 48 ₹7,200 Lowest | 63 ₹9,450 | 55 ₹8,250 |
| 5.00 | Supply & Laying of 4 Core XLPE 35 Sq. mm Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Havells/ Polycab/ Gloster/ RR Kabel/ KEI/ Mescab] | 80 | Mtr | 355 ₹28,400 | 403 ₹32,240 | 342 ₹27,360 | 255 ₹20,400 Lowest |
| 6.00 | Supply & Laying of 4 Core XLPE 25 Sq. mm Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Havells/ Polycab/ Gloster/ RR Kabel/ KEI/ Mescab] | 120 | Mtr | 295 ₹35,400 | 341 ₹40,920 | 189 ₹22,680 Lowest | 192 ₹23,040 |
Tender Value
Refer Docs
EMD Value
₹19,951
Closing Date
15 Sept 2025, 11:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
AMC of EI of whole system at Joint Administrative bldg. Salt Lake AdditionAlteration and modification of elec. dist. system and replacement of damaged fittings at diff. location and allied E.I work under Planning and Statistics as and when required
2025_WBPWD_895587_1
WBPWD/EE/BED/e-NIQ-75/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Joint Administrative Building
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,951
14 Oct 2025
29 Aug 2025
17 Sept 2025
8 Sept 2025
15 Sept 2025
8 Sept 2025
Amount
Dismantling of different existing El units (Old Tubelight fittings, Old TubeLight, downrod, Old Wires, etc.) as required and mending good the damages as per direction of EIC.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required (Make: Polycab/KEI/Finolex/Havells) 3 x 22/0.3 (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x(4 sqmm) + 1x(2.5 sqmm)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm)
2x(2.5 sqmm)+1x(1.5 sqmm)
2x(4 sqmm) + 1x(2.5 sqmm)
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19/25 mm, 3 mm thick Polythene pipe as per GS. 19 mm dia 3 mm thick
Supply & Laying of 4 Core XLPE 35 Sq. mm Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Havells/ Polycab/ Gloster/ RR Kabel/ KEI/ Mescab]
Supply & Laying of 4 Core XLPE 25 Sq. mm Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Havells/ Polycab/ Gloster/ RR Kabel/ KEI/ Mescab]
Supply of 4ft LED Box type Double batten with end cap complete with all accessories as per direction of EIC. [Phillips make Cat no-TMC 502 P 1XT-LED 22 W P3241/ Equivalent of Crompton]
[Phillips make Cat no-TMC 502 P 2XT-LED 22 W P3242/ Equivalent of Crompton]
Supply of 18W LED Tube [Philips: Mas LEDTube 1200mm 18W865 T8 I – 2100 lm / Crompton]
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length [15 /C-2]
Fixing only single /twin fluorescent /LED light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener incl. necy connection as per GS.
Supplying and Drawing 3 x 1.5 Sqmm, 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in the existing pipe and by the prelaid GI fish wire and making necy. connection as required.
Supplying and Drawing 1/2" dia PVC flexible pipe from Ceiling Rose to the Luminire as per direction of EIC
Two Coat White colour Painting of 2 No. 20 mm dia EI conduit of existing LED Set after dismantling & refixing as required as per direction of EIC.
S & Fixing of 240V, 90W LED Street light fittings as required as per dir. of EIC make Philips (BRP049LED110CWM2FGPSUGRV3/Crompton/Wipro)
S & F 240V 21A OLP - 3+ Electrronic motor starter with inbuilt digital display unit incl. S & F 175mm X 100mm X 65 mm 16 SWG MS Box concealed in wall with bakelite top cover after dismantling of damaged / old one incl. Necy. Conncetion as required (Make: Electron)
S & Replacing of 18W, Square (1' x 1') / Round type, LED, WW, Surface Mounted downlight (Philips /Crompton /Orient /Havells /Equivalent) as per direction of EIC
S & F of 15W, Square (8" x 8") / Round type, LED, WW, Surface Mounted downlight (Philips / Crompton / Orient / Havells / Equivalent) as per direction of EIC.
S & F of Recessed mounted, 15W, 6" Cut-Out, Round, deep inset diffuser (for visual comfort) LED complete with all accessories [Wipro: Mollis X: LD06X-171-XX-57-XX / Equivalent of Crompton / Philips] as per direction of EIC.
S & F of 3W, WW, Round (2.5" Cut-Out,) Adjustable Focused Spot Light (Tilt Option) (Make: Philips - Astra Spot COB 3W Tilt / Equivalent) as per direction of EIC.
S & Replacing of 5 Mtr Long, 28W, WW/CDL/NW, Low glare LED Strip Light with Driver [Phillips - Linea Premium / Bright/Glow/ Blue /ColorMagic 3 in 1/ Equivalent ] as per direction of EIC
S & Replacing of ceiling fans complete with all accessories having the following Model / Cat No. ( Make - Orient - New Breeze (White) / Havells / Crompton/ equivalent ) 36'' (900 mm ) Sweep as per direction of EIC.
S & Replacing of GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) (12")
S & F of Exhaust fans complete with all accessories having the following Model ( Make -EPC ) 9"( 225mm )
S & F of 220V,450 mm wall Bracket Fan [Make - EPC /Usha/ Orient-Tornado Wall II- Gun Metal]
S & F of 240V, 25A / 32A DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection after replacing of Isolator as per direction of EIC.
S&F of 240V, 10A /16A /20A SPMCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necy. connection after replacing of old MCB as per direction of EIC.
Supplying and fixing 240/415 V, 63A FP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
Supplying and fixing 240/415 V, 100A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
S & F of 220-240V, 4ft long, 20-watt, 3 in 1 Multicolour (CDL / WW / NW) LED Compact Tubelight set [ Make: Philips / Equivalent ] as per direction of EIC.
S & Replacing of ceiling fans complete with all accessories having the following Model / Cat No. ( Make - Orient - New Breeze (White) / Havells / Crompton/ equivalent ) 36'' (900 mm ) Sweep as per direction of EIC.
Supply & Pouring of fuel of 380 KVA Jakson Make D.G. Set including Carring Charges
S & R of valvoline premium blue 7800 plus ( Lube oil)
S & R of Seperator between Fuel & water (part no. - 4093731 / Equivalent).
S & R of Air filter primary (part no. - 4315239 / Equivalent).
S & R of air - filter safety (part no. - 4315238 / Equivalent).
S & R of Gasket kit for fittings of diesel injector set and Head gasket kit set.
S & Replacement RADIWASH (Part no. AX7013507 / Equivalent).
S & F Copper oil pressure ring
S & F Benjo bolts for fuel pipe Note:- i) Suitable quantity of Common / Regular EI materials like wires, Pipes, piano key type & modular type switches, sockets, MCB of different ratings, modular type switch boards, call bells, DG spare parts , DG fuel , Lubricant etc. should be stored at site by the Agency in advance with his own responsibility to overcome emergency situations. ii) Works through requisition (i.e, Regular work) should be started within 16 hrs & the emergency breakdown works should be started within 4 hrs with requisite manpower after getting the information either from site or from office. Each individual work must be completed with minimum executing time as per site requirement. iii) The Agency must submit the details of communicating person in this regard along with his Mobile number & Email id.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
FAIRWAY ENTERPRISE (BID ID -6912071)
ELECTROTECH (BID ID -6924922)
RIDDHI (INDIA) (BID ID -6927981)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .