Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹32.2 L+₹4.4 L (15.8%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹32.9 L+₹5.1 L (18.3%)Rejected-AOC 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC ok | |
| 4 | L4₹34.6 L+₹6.8 L (24.3%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-AOC ok | |
| 5 | L5₹35.7 L+₹7.8 L (28.1%)Rejected-AOC | L5 | Rejected-AOC ok |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
9 Jun 2022, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR/MAINT OF DG SETS AND ALLIED SERVICES AND EXTERNAL ELECTRIC LT SYSTEM AT BAREILLY CANTT UNDER GE WEST BAREILLY
2022_MES_515671_2
8039/C/E8
Open Tender
Civil Works
Item Rate
270 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹94,000
Yes
23 Jul 2022
13 May 2022
11 Jun 2022
13 May 2022
9 Jun 2022
28 May 2022
13 May 2022 - 27 May 2022
Amount
DG SET:-
General servicing of DG Set including B check ,cleaning of machine,replacement of oil filter,fuel filter and air filter ) cleaning of fuel tank, checking of oil level,checking of tension in fan belts,checking and repair of leakages in hose pipe, proper adjustment of tappet, checking of Governor control assembly, radiator,complete all as per manufactaures recommendations for following capacity and make of DG sets. Note: (i) Cost of all filters deemed to be included in the quoted rate of general servicing of DG Sets. (ii) Cost of Engine Oil to be included in quoted rate.
500/600 KVA Jackson Kirloskar DG Set
125 KVA Cummins/ Kirloskar DG Set
82.5 KVA Kirloskar DG Set
63/62.5 KVA Kirloskar/Ruston/Ashok Leyland DG set
20/40 KVA DG set Make : Kirloskar
15/10/7.5 KVA DG set Make : Kirloskar
Dismantling / stripping diesel engine of DG Det of 63/40 KVA rating capacity after separating alternator from common base frame setting a side for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detained inspection complete all as specified and directed. Note :- Spares shall be measurd & paid separately under relevent items of Sch 'A'.
Supply and fixing of the following spares for DG Set 63/40 KVA Make- Kirloska/Ashok Laylend required to be replaced under relevant item here in before complete all as specified and directed :-
(a) Piston std size Cat Part No. as existing.
(b) Piston Ring Cat Part No. as existing.
(c) Piston Pin Cat Part No. as existing.
(d) Cylinder liner (Sleeve) Cat Part No. as existing.
(e) Exhaust valve Cat Part No. as existing.
(f) Inlet valve -Cat Part No. as existing.
(g) Packing kit Cat Part No. as existing.
(h) Oil Seal Cat Part No. as existing.
(j) Oil Pressure guage Cat Part No. as existing.
(k) Kit "O" Ring Cat Part No. as existing.
(l) Fuel flexible pipe Cat Part No. as existing.
(m) Oil Filter with gasket Cat Part No. as existing.
(n) Diesel filter with gasket Cat Part No. as existing.
(o) Connecting Rod bush Cat Part No. as existing.
(p) Thrust washer Cat Part No. as existing.
(q) Valve guide inlet and outlet seat Cat Part No as existing
(r ) Cylinder Head Gasket Cat Part No as existing
(s) Packing kit.Cat Part No as existing
(s) Fuel injection pipes.Cat Part No as existing
(t) Air Filter Cat Part No as existing
(u) Primary element
(v) Stop Solenoid
Dismantling / stripping diesel engine of DG Det of 125 KVA rating capacity after separating alternator from common base frame setting a side for repair/replacement of all components/accessories including preparation of list of spares which are ascertained to carry out repair /replacement of detained inspection complete all as specified and directed. Note :- Spares shall be measured & paid seperately under relevent items of Sch 'A'.
Supply and fixing of spares for DG Set 125 KVA Make Kirlosker, Cummins required to be replaced under relevant item here in before complete all as specified and directed .
(a) Piston std size Cat Part No. as existing.
(b) Piston Ring Cat Part No as existing.
(c) Piston Pin as existing.
(d) Cylinder liner 22001-40847
(e) Exhaust valve Cat Part No as existing
(f) Inlet valve Cat Part No as existing
(g) Packing kit (Gasket) Cat Part No as existing
(h) Oil Seal Cat Part No as existing
(j) Oil Pressure guage (Precell) Cat Part No as existing
(k) Kit "O" Ring 7B -Cat Part No as existing
(l) Fuel flexible pipe Cat Part No as existing
(m) Oil Filter B-Cat Part No as existing
(n) Diesel filter Cat Part No as existing
(o) Connecting Rod assembly make kirloskar cat part no 4200910000
(p) Thrust washer YD -Cat Part No as existing
(q) Valve guide inlet and outlet seat Cat Part No as existing
(r) Cylinder Head Gasket / packet kit.
(s) Fuel injection pipes.
(t) Valve Solenoid
(u) Air Filter Cat Part No as existing
Reassembling the diesel engine after top overhauling and installation in its original place/position including testing commissioning of DG Set complete all as specified and directed of following capacities:-
(a) DG Set 63/40 KVA cap Make Kirloskar
(b) DG Set 125 KVA cap Make Kirloskar/Cummins
Griding, polishing of cylinder head, cylinder valve seats, valve guide etc all as required for best overhauling for DG Set 63/40 KVA Make- Kirloskar/Ruston complete all as specified and directed
Griding, polishing of cylinder head, cylinder valve seats, valve guide etc all as required for best overhauling for DG Set 125 KVA Make- Kirloskar/Cummins complete all as specified and directed
Overhauling, servicing/calibration of FIP (fuel injection pump) assembly of DG Set 125/63/40 KVA Make: Kirloskar/Ruston including replacement of nozzle /injection delivery valve holders benjo bolt copper washer roater bearing etc including testing complete all as specified and directed.
Suppy and fixing following spares parts of FIP of DG Set 63/40 KVA Make: Kirloskar/Ruston complete all as specified and directed (only unserviceble parts shall be replaced after inspection):-
(a) Elements of FIP (Make MICO 1200240183)
(b) Nozzle (-do-) 1267230814
(c) Plunger
(d) Delivery valve (-do-) 14185220471 HP
(e) Benjo Bolt (-do-) 29112037051 HP
(f) Seat Washer
(g) Bearing
(h) Tappet roller bush pin
(j) Control Rod 1416024007
(k) Fly weight assembly
(l) Governer spring
(m) Packing/Gasket 1411015052
Suppy and fixing following spares parts of FIP of DG Set 125 KVA Make: Kirloskar/Ruston complete all as specified and directed (only unserviceble parts shall be replaced after inspection):-
(a) Elements of FIP (Make MICO 1200240183)
(b) Nozzle (-do-) 1267230814
(c) Plunger
(d ) Delivery valve (-do-) 14185220471 HP
(e) Benjo Bolt (-do-) 29112037051 HP
(f)Seat Washer
(g) Bearing
(h) Tappet roller bush pin
(j) Control Rod 1416024007
(k) Fly weight assembly (MICO) 1428194000128
(l) Governer spring
(m) Packing/Gasket 1411015052
(n) Coolant for radiators
Overhauling, servicing/calibration of PT(Pressure Time) pumps assembly and Injector of DG Set 125 KVA Make: Cummins including replacement of Gear Pump /Pulsation Damper/ Teco Shaft/Main shaft and injector parts, Fly weight assembly bearing etc including testing complete all as specified and directed.
Suppy and fixing following spares parts of PT pumps and Injector of DG Set 125 KVA Make: Cummins complete all as specified and directed (only unserviceble parts shall be replaced after inspection):-
Gear Pump
Main Shaft
Techo Shaft
Throttle Shaft
Fly Weight assembly
Pulsation Damper
Bearing
Filter screen
Packing/Gasket Set
Barrel Plunger aasembly of Injector
Injector Cup of Injector
Supply and fixing of the following spares for DG Set 500/600 KVA Make- Jackson Kirloskar complete all as specified and directed :-
Oil Cooler Gasket
Oil Pan Gasket
Cylinder Head Gasket
Cylinder Head Cover Gasket
Water pump Gasket
Exhaust Manifold Gasket
Intake Manifold Gasket
O' ring Kit
Fan V Belt
Water Pump V Belt
Bearing
Cooling Nozzle
Thermostat
Impeller Water Pump
Sensor Tech complete
Water Separator
Supply , installation , commissioning and testing of Governor Controller Assembly complete Model - DWC-2000 Cat part No 65.11220.7008 CE certified . For 500 KVA DG sets Make - Jackson, Kirlosker
Supply , installation , commissioning and testing of Digital Display Controller card complete for Electric Control Panel of 500/600 KVA DG sets Make - Jackson, Kirlosker
Supply , installation , commissioning and testing of Electric Actuator Assembly complete for 500 KVA DG sets Make - Jackson, Kirlosker
Supply , installation , commissioning and testing of self starter 24 Volt make Doosan or equilavent as per sample for DG Set complete for 500/600 KVA DG sets Make - Jackson Kirlosker
Supply , installation , commissioning and testing of Priming Pump complete for 500 KVA DG sets Make - Jackson ,Kirlosker
Supply , installation , commissioning and testing of Relief Valve assembly complete for 500 KVA DG sets Make - Jackson, Kirlosker
Dimantling of FIP (fuel injection pump) assembly and FIP nozzles, Reassembling after repairing and calibration ,setting injection timing to aasure smoke less operation of DG Set 500/600 KVA Make: Jackson Kirloskar complete all as specified and directed.
Repairing/servicing/calibration of FIP (fuel injection pump) assembly of DG Set 500/600 KVA Make: Jackson Kirloskar including replacement of all unserviceable spare parts for 10/12 nos of cylinder engine of DG set including testing complete all as specified and directed.
Repairing and calibration of FIP Nozzle of DG Set 500/600 KVA Make: Jackson Kirloskar including replacement of all unserviceable spare parts for 10/12 nos of cylinder engine of DG set including testing complete all as specified and directed.
Opening of Cylinder Head , tappings , Griding, polishing of cylinder head, cylinder valve seats, valve guide etc and reassembling including tappet setting testing and trial complete all as required for best operation for DG Set 500/600 KVA Make- Jackson Kirloskar complete all as specified and directed
Rectification of water contamination i.e. water entering in Oil Chamber including replacement of seals and gaskets and nut bolts etc complete all as specified and directed
Repair of Governor Controller including setting and adjustment of Droop speed mode control Fuel control , stability controll, over speed control and testing complete of DG set Cap 500/600 KVA DG set Make- Jackson Kirloskar
Repair of Electric Control Panel of DG set of cap 500/600 KVA DG set Make- Jackson Kirloskar
Supply and fixing in replacement of Relay Card with Relay complete of Electric Control Panel of DG set of cap 500/600 KVA DG set Make- Jackson Kirloskar
Dismantling of radiator of DG Set 40 KVA/ 63 KVA / 125 KVA Make Kirloskar/ Ruston/Cummins complete all as specified and directed.
Repairing of radiator 40KVA/ 63 KVA / 125 KVA DG Set of make Kirloskar/ Ruston by brazing, soldering and cleaning of fins and descaling of tubes, replacement of new hose pipe set with clamp and fixing in original position and testing complete all as specified and directed.
Supply , and fixing including testing of radiator core of copper of 63 KVA DG set Make- Ashoka Leyland/Kirlosker/Ruston as per sample complete alla s specified and as directed.
Supply , and fixing including testing of radiator core of copper of 125 KVA DG set Make- Cummins as per sample complete alla s specified and as directed.
Dismantling unserviceable self starter 12 Volts of following capacity DG set of Make Kirloskar/ Ruston/Cummins and repair/maint by replacement of worn out parts like bendix pinion, piston, bush housing armature field coil, carbon bushes etc and refixing and testing for following cpacity complete all as specified and directed.
63 KVA & 40 KVA
Supply , installation , commissioning and testing of self starter 12/24 Volt make lucas/Bosch or equilavent as per sample for DG Set complete for 125 KVA DG sets Make - Kirlosker,Cummins
Supply , installation , commissioning and testing of self starter 12 Volt make lucas/Bosch or equilavent as per sample for DG Set complete for 63/40/20/10 KVA DG sets Make - Kirlosker,Cummins, Ruston
Dismantling, broken terminal shaft with MS cover for alternator of DG Set of any make /capacity and supply and connecting new terminal plates and cover of 1 mm thick MS sheet for alternator including cable connection complete all as required at site to complete the job as per approved sample complete all as specified and directed.
Dismantling of alternator from engine and stripping /opening replacement /rewinding the alternator with copper super enamelled wire of existing size and A class insulation for 63/125 KVA alternator make Kirloskar /Cummins /Crompton and refixing after alignment complete all as specified and directed.
S & F rectifier for DG Set 63/125 KVA cap Make Kirloskar complete all as specified and directed.
S&F Hr Run M/ Hr Meter including RPM Meter cable connection through Engine by making provision as necessary as per site requirement complete all as specified and directed.
S &F of turbo charger repair kit make ; Garrett Cat Part No. 0612321000 for 125/63 KVA DG Set Make - Kirloskar complete all as specified and directed.
S & F Core assembly of turbo charger Make Garrett complete all as specified and directed.
S & F Turbo charger garrett for kirloskar DG Set complete all as specified and directed.
S & F diesel fuel flexible pipe for DG Set of any capacity / Make complete all as specified and directed.
S&F of oil pressure pipe as per sample Make : Ashoka Leyland complete all as specified and directed.
S & F hose pipe flexible Cat part AK 5040 SS of Make Cummins
S & F hose pipe flexible Cat part AK 6065 SS of Make Cummins
S & F Oil cooler for DG Set 63 KVA/125 KVA capacity of make Kirloskar complete all as specified and directed.
S & F Lubricating oil pump for DG set 63 KVA/100 KVA capacity of make : Kirloskar and testing complete all as specified and directed.
S&F in repair cut out 12 Volts automatic of make : Lucas/Bosch and testing complete all as specified and directed.
S & F ignition switch with replacement of auto wiring suitable for DG Set of any capacity make complete all as specified and directed.
S & F battery charger suitable for charging of battery 12 Volts 90/180 AH with charging current 0-10 Amps, input voltage 230 Plus complete all as specified and directed.
S & F alternator for battery charging 12 Volts 180 AH with pulley complete all as specified and directed.
S & F battery cables of following sizes complete all as specified and directed:-
(a) 78 " long (+)
(b) 78" long (-)
S & F battery terminal brass heavy duty complete all as specified and directed.
S & F of battery charging meter (0-30) range complete all as specified and directed.
S & F oil temperature gauge Make AE, Dass Mesh, Siemens complete all as specified and directed.
S & F superior quality asbestos ropes 8 mm dia duty bed resistant ISI Marked of make : Everest / Crompton complete all as specified amd directed.
Supply only distilled water in 5 Ltr Jericanes complete all as specified and directed.
S & F Anti vibration pad set for DG Sets as per site requirement complete all as specified and directed.
S&F Fan belt of following sizes complete all as specified and directed :-
Repair of Electric Panel of DG set capacity 125 KVA make- Kirlosker Bliss without any damage to the serviceable equipments complete all as directed.
Supply and fixing in replacement of following spares/parts of Electric Panel of DG set capacity 125 KVA make- Kirlosker Bliss
Pro com controller
Relay Card
Oil safety controller
Engine Temperature Safety controller
Battery charger 24 Volts
Connection plate
Push button with NO NC
Toggle switch
CT(current transformer) 6500T/6600T
Engine Harness
Panel Harness
OEM relay with base
Ampmeter
Repair/Maintenance of Automatic Voltage Regulator (AVR) of DG Set of Capacity 500 KVA/600 KVA installed at MH including replacement of all minor and major parts like Ics, Rectifier,diodes, capacitors, resistance, relay,Printed circuit board etc. and refix the same after complete repair and testing on load complete all as specified and directed.
Supply and fixing in replacement Automatic Voltage Regulator (AVR) of DG Set of Capacity 500/600 KVA of the existing make type and capacity and testing on load complete all as specified and directed. Make : as per existing/as recommended by OEM.
S&F in replacement Automatic Voltage Regulator (AVR) of DG Set of following Capacity. Make Cummins/Kirloskar/Ruston and testing on load, complete all as specified and directed. Note:- The AVR installation should be done through experienced electrician cum DG mechanic and the AVR should be capable of regulating and maintaining the desired Voltage rating after installation.
(a) DG Set 125 KVA
(c) DG Set 63/40/20 KVA
Supply and fixing Battery 12 Volt 88 AH Make: Exide/Luminous complete all as specified and directed
Supply and fixing Battery 12 Volt 150 AH Make: Exide/Luminous complete all as specified and directed
Supply and fixing Battery 12 Volt 180 AH Make: Exide/Luminous complete all as specified and directed
Repair/maintenance of DG sets of any capacity ranges from 10 KVA to 600 KVA and any make and Model by qualified DG Set mechanic cum electrician by testing of complete units, and panels and governor Control setting and voltage fluctuation rectification including testing of self starter and battery and AMf panel and control panel etc and find out/detect the faults by setting/adjustment and rectify the defects in situ by using required spares and repair jobs and cleaning / normal maintenance to the DG Set complete to make the DG set functional in all respect complete all as directed by Engineer-in-charge.
Note: (a) Spare parts and repair jobs of DG sets are measured separately under relevant items. (b) Register must be maintained by the contractor for the jobs carried out during breakdowns attending complaints and rectification of faults. (c) In this job only breakdown faults will be measured as a job. and Minor and other major repairs and periodical,general servicing and preventive maintenance will be not considered in this job it will be measured in the respective repair jobs/refixing of spares items sub part. (d)The complaint lodged regarding unserviceability of DG set must be attended by the qualified technician within 1 hour of complaint lodged and must be rectified on same day . A penalty of 1000 per day will be deducted from the contractor dues if complaints not attended or not rectified.
M&L for Earthing complete with galvanized earth plate electrode of size 60 cm x 60 cm x 6.00 mm buried directly in ground vertically at a depth not less then 2.25 Mtrs below normal ground level with top edge of earth plate at a depth not less then 1.5 Mtrs below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made of galvanized iron and protected by light grade 40 mm dia GI pipe upto test point or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:3:6 type C2 (using 40 mm grade stone aggregate) including excavation and earth work in any type of soil, returning, filling in soil and disposal of surplus soil to a distance not exceeding 50 Mtrs all as specified and shown on plate No 05 of SSR Part I 1991.
M&L Galvanised iron strip of size 32x6 mm burried in ground/on wall ,
Supply and Fix ON load change over switch 415V in sheet metal enclosure 4 pole of capacity 250 Amps complete all as specified and directed.
Supply and Fix ON load change over switch 415V in sheet metal enclosure 4 pole of capacity 400 Amps complete all as specified and directed.
Refilling of fire Extinguser ABC type of capacity 10kg (incl monomonium phosphate and silicon and Pressure of nitrogen as required for 10 kg ) complete all as specified and directed.Note:-Cost of locking arrangement after refilling and painting work included in coated rate.
Notes: (i) Complaints pertaining to DG Sets shall be resolved by the contractor within 24 hrs of getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs 500 per day per complaint shall be imposed on the contractor. (ii) The contractor or his authorised representative shall report to the concerned JE E/M at 09:00 hours dailly on all working days to receive order/instructions of the work. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in-charge/JE E/M concerned. (iii) Work done register to be maintained by the contrator.
EXTERNAL ELECTRIC LT SYSTEM:-
Dismantling of LT PCC/steel tubular pole/stay assembly/street light of any size and discription incl coping, foundation etc and dismantling of serviceable insulators from poles for reuse and shifting to E/M yard or any other location.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
M&L for stay assembly comprising of stay bow 40 cm long, 14mm dia complete with accessories as shown in electrical plate No -1 of SSR Pt- 1 with and including 20 mm dia stay rod , 215 cm long with threaded ends ,GI nuts, bolts , washers, thimbles including nuts, bolts and washers, 300mmx300mmx6mm stay plate, 7/8 SWG strand GI wire and also exposed surfaces shall be given two coats of aluminum paint over a coat red oxide primer complete including dismentling of existing damaged assembly. Note :- Stay clamps, Stay strand, PCC excavation and earth work shall be measured and paid for seperately.
Dismantling stay assembly complete from the pole all as specified and directed by Engineer -in-Charge.
Supply and fixing in replacement of stay wire stranded of size 7/3.15mm made of galvanised steel wire all as specified and directed.
Supplying,drawing and fixing in replacement of continuous GI earth wire/guard/cradles of 4mm dia including GI binding wire 1.63 mm and GI eye hook on LT poles incl taking down old rusted GI wire all as specified and directed.
Supply and fixing in replacement, loop type insulators, vitreous porcelain white, brown or green with over all size 65x90mm with clearance dia of the hole 16mm including removal of old broken insulators.
Supply & fixing in replacement shackle type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, including removal of existing insulators.
Supply & fixing in replacement pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, including removal of existing insulators.
Fixing of ACSR conductor, removed under relevant items on existing or new LT poles including binding with 02 mm dia aluminium binding wire all as specified and directed by Engineer-in-charge.
Supply & fixing in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire all as specified & directed by the Engineer-in-charge.
Supply, fabricating and fixing in replacement of cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint all as directed by Engineer-in-charge.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces including broken of existing PCC all as specified & directed.
All as per srl item No 13 here-in-before but PCC 1:3:6 type C-2 as in foundation of stays and coping of poles.
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for LT cables complete including bricks all as specified & directed.
Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches/ducts complete all as specified & directed.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat/lengthwise perpendicular to the axis of cable all as specified & directed.
Supply and laying in replacement of OH ACSR Conductor / XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sq mm 4 core all as specified and directed. Note :- Rate deemed to be inclusive of connection including cable glands and lugs.
All as per Ser item No 96 here-in-before but 25 Sq mm 4 core
All as per Ser item No 96 here-in-before but 50 Sq mm 3.5 core
All as per Ser item No 96 here-in-before but 95 Sq mm 3.5 core
All as per Ser item No 96 here-in-before but 120 Sq mm 3.5 core
Supply and fixing 1100 volt grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections , twin core cable flat or circular of size 10 Sqmm all as specified.
Taking down of old aluminium conductor of any description /size from LT Poles including cross arms, bracing and other steel accessories.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M&L Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.
M&L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 80/50 mm bore at the depth not less than 1 mtr below ground level for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measure and paid separately under respective item.
S & F in replacement GI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a) 50 mm dia
(b) 80 mm dia
Supply and fixing of PVC LT OH line spacer for 3 wires complete all as specified and directed.
Supply and fixing of PVC LT OH line spacer for 4 wires complete all as specified and directed.
Supply and fixing of PVC LT OH line spacer for 2 wires complete all as specified and directed.
Removal of Tree fallen on HT/LT overhead lines by cutting branches,bushes by electric cutter or manual and lifted by crane /Hydra/Manual including collection and depositing the retrieved timber at a place as directed by Engineer-in-charge. Safely equipment & T&P must be provided by the contractor and rates of such equipments are to be included in quoted rates.
Opening the binding wire from pin /shackle insulator on steel pole of any height for re-stretching the ACSR conductor , after re-stretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: (i) The above work includes clearing /prooning of tree branches falling around the conductors. (ii) Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid.
Opening the binding wire from 'J' hook or opening nut, bolts,of cross arms on steel /pole of any height for re-stretching the galvanised iron earth wire any size, after re-restretching without kinks & bends, binding the 'J' hook with appropriate size of aluminium binding wire or fixing with appropriate size of nut,bolts,washers complete all specified & directed by Engineer-in- charge. Note: (i) Cost of binding wire,nut,bolts and washers deemed to be included in the quoted rate, No extra amount will be paid.
Repair to LT panel of any size in different location with arc/gas welding with replacement of hinges and place the door in original position, replacement of door locks and replacement of indicator lamp (1 set) rotary switch including painting complete with two coat synthetic enamelled paint over red oxide primer complete all as specified
Taking down u/s MCCB 4 pole 630 Amp 415 Volt and S & F in replacement MCCB 415 Volts 4 pole 630 Amps 50 Hz 50 KA of existing make model and type alongwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor
All as per Item above but of MCCB 500 Amps 4 pole 50 Hz 415 V with rupturing capacity 50 KA
All as per Item above but of MCCB 400 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA
All as per Item above but of MCCB 315/350 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA
All as per Item above but of MCCB 250 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA
All as per Item above but of MCCB 200 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA
All as per Item above but of MCCB 100 Amps 4 pole 50 Hz 415 V with rupturing capacity 16 KA
S&F in repair Cable end termination 11000 volt high voltage (heat shirnkable) cable jointing kit for 1000 Volts (Earthed) grade cable for indoor /outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
All as per above here-in-before but size of 120 to 185 sqmm complete all as specified and directed.
S&F in repair Straight through 11000 volt high voltage (heat shirnkable) cable jointing kit for 11000 volts ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of of size 120 to 185 sqmm complete all as specified and directed.
All as per above here-in-before but size of 95 sqmm complete all as specified and directed.
Supply, fixing, testing and commissioning of Heat shrinkable type end termination jointing kit suitable for LT cable of size 35 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade.
All as per above here-in-before but 95 to 120 Sqmm.end termination jointing kit
All as per above here-in-before but 150 to 185 Sqmm.end termination jointing kit
Supply, fixing, testing and commissioning of epoxy type straight through jointing kit suitable for LT cable of size 35 Sqmm to 70 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade.
All as per item No above here-in-before but 95 to 120 Sqmm.
All as per item No above here-in-before but 150 to 185 Sqmm.
Supply& fixing in repair PVC jumper cable of size 70 Sqmm aluminium,single core suitable for 1100 volts and removing the old burnt/ worn out jumper complete all as directed by the Engr-in-Charge.
All as per item No above here-in-before but & size 95 Sqmm.
M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way open ing duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 250 Amp 35 KA (Make Havells /Standard) complete all as sepcified and directed incl making connection /thimbles etc complete.
All as per srl item above here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB and bus bar rating 400 amp
Supply and fixing street light bracket made out of 40 mm dia GI pipe light grade of length upto 1.2 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed.
Cleaning and preparation of old painted surface of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets,street light brackets.cross arms and making Red & white strips with synthetic enamelled paint of 30cm height,each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified
Lopping / prooning of tree branches upto the extend to obtain clearance all around the over head lines conductor upto 3 mtr from furthest conductor on pole and pole to pole one span including removing of cut branches and cleaning of site complete all as specified and directed. Note :- (a). The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b). Prooning of all tree branches in one tree shall be measured as one Job. c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f). The contractor will provide proper tools and safety devices to his staff for prooning of trees.
Cleaning of surrounding areas from large grass weeds ,vegetation, shrubs branches of trees at substations, near Transformers ,near Electric pole structures by manual /Electric Grass cutting machine/JCB etc with complete grass and vegetation clearance from ground without any damage to the electric cables and items complete all as specified and as directed by Engr-in-Charge. Notes: Rates of T&P must be included in the quoted rates
Notes:
LEEJA ENTERPRISES
M/S Rajeev Sharma and Co.
prabhave traders
VINYAK TRADERS
Ishtiaq and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .