Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.1 LAccepted-AOC MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹92.7 L+₹7.6 L (8.93%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹1.0 Cr+₹16.1 L (18.9%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹1.0 Cr+₹18.9 L (22.2%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
18 Jan 2024, 6:00 pmClosed
Col KK Srivastava, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special repairs to retaining wall behind block 7 hill top wardroom mess, As and As to P 83 building at MT section at INS Satavahana, As and As and special repairs of Upavan Park infront of family wing adjacent to building No. P 33 and As and As to r
2023_MES_621855_2
82381/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class B and Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹1.8 L
Yes
13 Apr 2024
28 Dec 2023
20 Jan 2024
28 Dec 2023
18 Jan 2024
4 Jan 2024
Amount
Surface dressing not exceeding 15 cm deep and getting out in Soft / Loose soil complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/ dense soil complete all as specified and as directed.
Excavation in post holes each not exceeding 0.5 Cu.m, getting out in Soft / Loose soil, including returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed.
Excavation over areas not exceeding 1.50 m in depth and getting out in Soft / disintegrated rock complete all as specified and as directed.
Excavation over areas depth exceeding 1.5m but not exceeding 3 m in depth and getting out in Soft / disintegrated rock complete all as specified and as directed.
Excavation over areas depth exceeding 3m but not exceeding 4.5 m in depth and getting out in Soft / disintegrated rock complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M & L for Hardcore of gauge exceeding 63mm but not exceeding 100mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to true surface complete all as specified and as directed.
M & L For Hand packing of broken stone/boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level of gauge 40 to 80mm complete all as specified and as directed.
Supply and Spreading of river bed boulders of size 7cm to 15 cm dia of average thickness 10 cm complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5KM complete all as specified and as directed.
Demolition of Reinforced Cement Concrete as in Roof, Floors [other than ground floor], beams, staircase, landing, Chajjas and similar suspended work including reinforcement cut as required to facilitate demolition and removing rubbish to a distance exceeding 10.00 KM and not exceeding 15.00 KM complete all as specified and as directed.
Demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete etc complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1, using 20 mm graded stone aggregate as in Bed blocks and Bed plates including weathering, slightly rounded or chamfered angles and throating, necessary form work etc complete all as specified and directed.
M & L for PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in benching, channel, side packing, haunching of paver block including necessary form/ moulds, etc. complete all as specified and as directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in roof kerb/padding as levelling coarse to maintain slope of existing roof complete all as specified and as directed.
M & L for 100 mm thick, PCC 1:2:4, Type B-2, using 40mm graded stone aggregate as in Floors / Hard standing etc, surface finished even and smooth with out using extra cement and spike rolling to surfaces or making impressions of expanded metal, while the concrete is green complete all as specified and as directed.
M & L for RCC M-30 design mix, using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and as directed.
M&L for Providing light weight AAC block bats concrete 1:3:6 mix (1 part of cement : 3 parts of coarse sand : 6 parts of AAC block bats of size 40-60 mm) mixed with approved water proofing compound as per manufacturer's instructions, as in filling in sunken floors, well rammed and compacted as required complete all as specified and as directed. Notes:- [a] The AAC block bats shall conform to relevant IS and all necessary tests shall be carried before incorporating the same in the work. [b] Care shall be taken prior to filling, that all pipes passing through sunken portion are pressure tested by maintaining pressure for 24 hours and junctions of pipes passing through walls, slabs are well grouted and sealed. Necessary testing shall be carried out by ponding water for required depth and maintaining continuously B141for 72 hours and any leakage found shall be immediately rectified without any extra cost. [c] Rate quoted by the contractor shall be deemed to include for the cost of working at all levels, leads and heights. [d] Water proofing compound shall be measured and paid separately at supply only rate under relevant item of this BoQ.
Use and removal of steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Walls, Retaining Walls, Basement Walls, Ballast Walls and the like, any thickness above top of footings including attached pilasters and buttresses etc complete all as specified.
Use and removal of steel formwork [Plain / Curved] to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc. vertical or to batter for ROUGH finished surfaces of concrete complete all as specified.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Slabs supported on walls, beams, columns, landings, shelves and the like complete all as specified and as directed.
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed.
M & L for applying Chemical Injection Treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60 mm deep @ 100 cm grid at bottom floor and all the internal wall surfaces of the sunken slabs of toilet by injecting Cement Slurry mixed with Grout Admixture "CONBEXTRA EP 10" of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Batik India Pvt. Ltd. at 225 Grams for 50 KG of cement and applying a coat of Brush Bond RFX of M/s. Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer's instructions complete all as required and as directed at site.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
Supply only integral water proofing compound [ISI marked] of approved make.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in Cement Mortar 1:4 complete all as specified and directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 8mm dia bars at every fourth course of brick work complete all as specified and as directed.
Supply and lay Bricks, common burnt clay building bricks, sub–class "B", Designation 75 in trenches for cable protection complete all as specified and as directed.
M & L for Providing Precast Cement Concrete Solid Block Masonry of 1:3:6, Type C1 using 20mm graded stone aggregate exceeding 100mm width with plain or interlocking joints set in cement mortar 1:6 complete all as specified and as directed.
Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, Cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F 35mm thick factory made Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [a] and fitted to Chowkats complete all as specified and as directed.
S & F 35mm thick factory made Second Class Hard Wood, Plain framed, Panelled Shutter [Two Panel] with Lock Rail and Panel of 9 mm BWP Commercial Ply or 12 mm Veneered Particle Board with Commercial Veneering on both faces, the size of Rail and Stile as per IS – 1003 [Part – I], Kiln Seasoned and Chemically Pressure treated and fitted to Chowkats complete all as specified and as directed.
S & F in repairs Stainless steel kitchen sink with drainage board, made of stainless steel sheet of 1 mm thick, with plugs, washers, Waste Fittings, 32 mm dia, Brass, Chromium plated, and 32mm dia PVC flexible Waste Pipe, 750 mm long, including bedding in Cement Mortar to dwarf wall or including fixing cantilever CI Brackets and connecting union to waste pipe, over all size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed.
S & F in repairs Stainless steel kitchen sink, made of stainless steel 1 mm thick, with plugs, washers and Waste Fittings, 32 mm dia, Brass, Chromium plated, and 32mm dia PVC flexible Waste Pipe, 750 mm long including bedding in cement mortar on to dwarf wall or including fixing cantilever CI Brackets and connecting union to pipe, overall size 495mm X 420mm, bowl size 410mm X 330mm X 160mm complete all as specified and as directed.
S & F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
S & F Factory Made Solid PVC Moulded Door Shutter, with Particle Board Core, 28 to 30mm thick [Stiles], with 2, 4, or 6 raised panel design with 2mm thick wood grain moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, fixing in frame at site as per specification & drawing shown on Serial Page No. 161 of MES Schedule Part - II complete all as specified and as directed.
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality complete all as specified and as per Manufacturer instructions. Note:(a) For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (b)The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.
S & F Factory made UPVC Sliding Window, Three Track, White Colour of area not exceeding 2.0 Sq.m, made of extruded profiles with wall thickness of 2.3mm±0.2mm, Window profile with hollow section with multi chamber, Frame of size 112mm X 45mm, Sliding Sash of size 42mm X 67mm, Sliding Mesh Sash of size 42mm X 57mm, Sliding Interlock [One vertical length in each shutter] of size 45.50mm X 28mm, Glazing Bead of size 24.50mm X 16mm shall be mitred cut and fusion welded at all corners, including drilling holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM Gasket, 1.2mm±0.2mm thick Galvanized Steel Frame of size 30mm x 12mm, 2 Nos, Sliding Sash of size 30mm x 18mm, Sliding Mesh Sash of size 26mm x 10mm, profile to be inserted in required profile, frame shall be fixed to the wall with 8mm X 100mm long fasteners, complete all as specified and as per Manufacturer instructions. Note: (i) The unit rate quoted by the contractor includes cost of fixing of grills, galss panes and wire cloths including all other connected accessories. (ii) The Grills, Glass Panes and wire cloths shall be measured and paid saperately at supply only rates under relavent Items of this Schedule. (iii) The size of UPVC sections specified in the description of item is minimum requirement, if the same size of section is not available, next higher size shall be provided by the contractor without any extra cost to the Department.
Supply only Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm complete all as specified and as directed.
M & L for aluminium sections of approved colour for doors, Windows, Ventilators, Partitions, with frames and shutters fully or partly glazed, sliding / openable, with extruded aluminium sections not less than 1.5mm thick and powder coating not less than 60 micron thick including necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, aluminium butt hinges , aluminium tower bolts, stainless steel friction hinges, locking arrangements etc. complete all as specified and as directed. Notes: [a] The size of aluminium extruded sections shall conform to Designation 63400 all shall be as specified in relevant IS code and as specified in MES Schedule Part - I. [b] Panel inserts such as Glass / Particle board / Gauze shall be measured and paid separately at supply only rates. [c] Weight of aluminium sections shall only be accounted for payment purpose. Weight of aluminium Handles, Butt Hinges & Tower Bolts shall not be accounted for payment purpose. [d] The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges,Peg stays, locking arrangements etc., and fixing only of panel inserts of glass / particle board / gauge etc.
Supply only 4mm thick Tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only 12mm thick Prelaminated Particle Board, both Side Decorative Choice Lamination, Medium Density, Interior Grade complete all as specified and as directed.
Supply only 5.5mm thick Sheet Glass ordinary quality in squares exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed.
S & F for Providing and fixing stainless steel (Grade 304) hollow tubes,channels, plates etc. As in Park Bench/Chairs including welding,grinding,buffing,polishing, making curvature (where required) and fitting the same with necessary stainless steel nuts & bolts including fixing with all necessary accessories complete all as specified and as directed.
S & F 2.00mm thick Plain, Galvanised, Mild Steel sheeting, in ridges, hips, valley gutters, drip and straight flashings [length and girth as required at site in single piece] with grade of Zinc coating 275 GSM fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A, as in Joist, Channel, Angle, or Tee Sections, fixed independently, without connecting plates etc [cut to ordinary lengths i.e. within 20mm of the length indicated] complete all as specified and as directed.
Supply only Chain link MS galvanised fencing, any size or type, complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed. Note: Supply only chain link fencing shall be measured & paid separately.
S & F MS machine made screw bolts with hexagonal or square head one end and screwed other or screwed both ends, fitted with washers and one hexagonal or square nut exceeding 15 cm long and not exceeding 22.5 cm long, dia of neck exceeding 16 mm but not exceeding 20 mm complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed.
S & F Floor Door Stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
S & F in repairs Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F 100 mm size, Butt hinges, Stainless Steel, with SS hinge pin including fixtures complete all as specified and as directed.
S & F 125 mm size, Butt hinges, Stainless Steel, with SS hinge pin including fixtures complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Dismantling of Mild Steel or Wrought Iron Work of any description not otherwise provided for complete all as specified and as directed.
Dismantling of Structural Steel work including Doors, Gates etc but excluding framed trusses complete all as specified and as directed.
S & F Steel rolling shutters, thickness of laths of 1.25 mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, Gear Operated type with bevel gear box and crank handle complete all as specified and as directed. Note: Safety lever lock and ball bearing shall be measured and paid separately at supply only rates.
Supply only Safety Lever Lock Mild Steel with 4 Levers suitable for rollong shutters complete all as specified and as directed.
Supply only Ball Bearing of size 65mm inner dia suitable for rollong shutters complete all as specified and as directed.
S & F Mild Steel work confirming to Fe - 290, Grade E-165, as in framed work such as Grills, Gratings, Ladders etc with ends of bars shouldered and/or riveted, or forged into spikes, framed Guard Bars, Barred Iron Doors, Ladders, framed Balusters, Walk Ways, Railings, framework of Water Tanks and similar work complete all as specified and as directed.
S & F Rolled Mild Steel work confirming to Fe 410-W, Grade-E- 250, Quality-A as in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings [exclusive of steel sheeting or other covering, running rails and guides] and hanging, also fastening and fixing complete all as specified and as directed.
S & F Seamless Calcium Silicate False Ceiling made out of 10mm thick, 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having Phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish and applying two or more coats of Cement based Wall Care Putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer and including Frame Work using GI perimeter channels of 0.55 mm thick, having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, fixed to wall with nylon sleeves and screws at 450 mm intervals, GI intermediate channels of size 45 mm X 15 mm X 0.90 mm supported with GI ceiling angles of size 25 mm X 10 mm X 0.55 mm fixed to soffits with steel expansion fasteners / GI cleats at 1220 mm intervals, ceiling section of 0.55 mm thick having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm fixed to intermediate channel with connecting clips and in direction perpendicular to the intermediate channels at 457 mm centre to centre including Dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed.
M & L for Roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description and removing rubbish to a distance exceeding 10.00 KM but not exceeding 15.0 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
Dismantling of stone slabs and tiles in flooring, apron etc of any description or thickness laid dry and pointed in any mortar complete all as specified and directed.
M & L for 75 mm thick, PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Sub base for flooring complete all as specified and as directed.
M & L for 25 mm average thick PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in levelling course over sub base, surface finished even and fair to receive topping layer complete all as specified and as directed.
M & L for 75mm thick PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth with out using extra cement and providing 12mm thick joints for full depth of PCC at every 3.00 m and every change of direction duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade of any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
Forming jambs etc to openings with stone supplied by MES including cutting, toothing and properly bonding in to old work including facing and pointing [if necessary] to match existing work, complete built in Cement Mortar 1:4 complete all as specified and directed.
Making good under cills [or over arches, lintels and bressummers] including all pinning as necessary complete built in Cement Mortar 1:4 complete all as specified and directed.
M & L for Forming Contraction Joint [Dummy], 65mm deep X 10mm wide, filled with sealing compound and sealed with Sealing Compound Grade "A" for 150mm thick flooring complete all as specified and directed.
M & L for Chequered Cement Concrete Tiles of size 250 X 250 mm / 300 X 300 mm, 25mm thick, Hydraulically pressed as in Floors, with grey cement and pigments, set jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 10 mm thick as in vertical surface , set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over a backing coat of 10 mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 8 mm thick [Square or Rectangular] as in vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, of size exceeding 0.18 Sq.m and not exceeding 0.36 Sq.m, 8 mm thick [Square or Rectangular] as in vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Floors, Treads of Steps, Window Cills, Cooking Platform etc., and the like with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Skirting, Dado, Risers of Steps, Jambs, Pillars, Wall Lining [Veneering to Wall] etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including diagonals, inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: Single stone slab shall be used for entire height of Skirting / Dado / Risers and joints shall match with the flooring.
M & L for machine cut Kota stone slab as in flooring using 20 to 25mm thick slabs, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for Inter Locking Paving Blocks of 80mm thick, made with M40 Grade cement concrete using 20 mm graded stone aggregate, Hydraulically pressed of approved colour and pattern, shape and size conforming to IS - 15658 set in floors complete all as specified and directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:3, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:3, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparing newly plastered Wall surfaces by using vaccume based sanding machine and applying two coats of Acrylic washable Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on wall surfaces by using vaccume based sanding machine, removal of nails and applying upto 1mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one of alkali resistant primer on wall surfaces complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer of same manufacturer as that of paint on newly plastered walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccume based sanding machine complete all as specified and as directed. Note:- The contractor shall carryout Exterior Emulsion Painting and allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out exterior emulsion painting through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on walls surfaces by using vaccume based sanding machine, removal of nails including rubbing with sand paper to obtain a smooth surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls complete all as specified and as directed. Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on Wall surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Interior Acrylic Emulsion over one coat of alkali resistant primer on Wall surfaces complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for two coats of white wash on old decorated surfaces of wall etc including necessary preparation by brooming down or steel wire brushing complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for One coat of synthetic enamel paint on old painted wooden surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for One coat of synthetic enamel paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
Dismantling water tanks of size exceeding 500 litres and not exceeding 1000 ltrs and removing to store complete all as specified and as directed.
Supplying and laying GI tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc laid in trenches including testing complete all as specified and as directed. Note: Earth work and excavation will be measured and paid separately.
Supplying and laying GI tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls including testing complete all as specified and as directed.
S & F in repairs UPVC Pipe of 50 mm bore, of pressure rating 10 KGf / Sq.cm including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, sockets etc and fixed to walls, ceiling, and laid on floors including testing complete all as specified and as directed.
S & F CPVC Pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing including taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed.
S & F CPVC Pipes 25 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing including taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed.
S & F CPVC Pipes 40 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing including taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fix to walls including taking up / down unserviceable / cracked Cast Iron pipe 100/150mm dia including taking out joints of any type complete all as specified and as directed.
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fix to walls including taking up / down unserviceable / cracked Cast Iron pipe 100/150 mm dia including taking out joints of any type complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 160 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Branch Piece, Single [Single "Y"] equal or unequal jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Branch Piece, double [Double "Y"] equal or unequal including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Double "T"] equal or unequal including jointing with solvent cement complete all as specified and as directed.
S & F PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F 75mm bore PVC [SWR] Multi Floor Trap with grating including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 100mm size Stainless Steel grating for Floor Traps complete all as specified and as directed.
S & F 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle including brackets and connections to pipe and flush pipe complete all as specified and as directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Double Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
S & F Ball Valves, 40 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc complete all as specified and as directed.
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 50 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Bib Taps, 15 mm dia, Brass Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.
S & F in repairs Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. KUP-35041PM or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Stop Valves, 15 mm bore dia of pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and as directed.
S & F Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as per Jaquar Catalogue No. OPP-15001PM or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F Vitreous China Urinal, Half Stall Type, Flat Back or Corner Wall Type, White, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, including urinal spreader of PTMT any colours for fixing with 15mm dia pipe and necessary fixing accessories etc. and including of curve shaped urinal partition with 10mm thick frosted glass with necessary fixing accessories complete all as specified and as directed. Make: Model No. for Urinal URS-WHT-132530 of Jaquar & Company Pvt. Ltd. or equivalent in Prayag / Kohler / Roca / Cera [First Quality] / Hindware [Italian Collection] / Parryware [Superfine] / Johnson Pedder & Model No. for glass partition 1810-UC/1110UC, JSE CHR 110UC450X of Jaquar & Company Pvt. Ltd. or equivalent in Prayag / Kohler / Roca / Cera [First Quality] / Hindware [Italian Collection] / Parryware [Superfine] / Johnson Pedder
S & F Health Faucet with 1 m long flexible tube, wall hook, non return valve complete as per Jaquar Catalogue No. ALD-577 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Stainless Steel, Soap Dish, Fancy Type complete all as per Jaquar Catalogue No. AQN-7731 or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & F in repairs Tumbler holder complete as per Jaquar Catalogue No. AQN-7741 or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & F in repairs Stainless Steel Toilet Paper Holder, Chromium plated, Fancy type complete all as per Jaquar Catalogue No. AKP-35753PS or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, including flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and as directed.
S & in repairs F Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe, PVC Connection of PTMT complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point complete all as specified and as directed.
All as per Serial Item No. 157 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 157 above but one 3 Pin Switch Socket Outlet 15 Amps power point on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 157 above but one AC / Geyser point on independent board, with 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Energy efficient Post Top Lantern, of not less than 3500 Lumens output, 5700 K, with Pressure Die Cast Aluminium Housing, IP65 Protection, electronic driver, all accessories internally prewired and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch Modular type, one module, Single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 5 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps cum 6 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, Two Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F TV Socket / Outlet, Co-Axial, Deluxe, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F Rigid non-metalic 20 mm dia PVC conduit exclusive of boxes(junction/terminal) but inclusive of all tees, bends, elbows, reducer, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles pipe hook etc. complete all as specified and as directed.
S & F SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including stove enamel steel Conduit 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia stove enamelled Conduit will be measured as one unit.
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 5 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 2 Core, 10 Sq.mm cross section suitable for earthed system, laying in trenches/duct/fixed to poles/drawn through pipes/sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
Supplying and Laying PVC insulated, sheathed Multistranded flexible copper conductor cable of size 3 Core, 1.5 Sq.mm including testing complete all as specified and as directed.
s & F IP 66 junction box made of impact resistance polycarbonate & heat resistant materials of size 155 x 100 x60 mm ,dust proof, water tight, light weight, acid resistant, corrosion proof insulated and shock proof,fire retardant self extinguishing,halogen & silica free non toxic material, UV resistant with internally embedded gasket suitable to 10 to 25 Sqmm cable including 01 No 5/6 Amp MCB 50 Amp rated 3 pole and neutral connector fixing arrangement with MS flat of size 25 x 3 mm with necessary nuts, bolts and washer complete all as specified and as directed.
Supplying and laying GI pipe, 40mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
M & L for Taking down Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 Mfd, Nuts & Bolts, washers, etc. including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
S & F MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F MCB, SPN, 40 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 240 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, TPN, 63 Amps, 10 KA, 'C' Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1000 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F RJ45 computer /LAN jack with shutter with metal box mini complete all as specified and as directed. Make:-Anchor Cat part No-30555 and Equivalent in Philips, Bajaj , Crompton
S & F and testing of timer switch 63 A, 3 Pole, 230 V Operating voltage, panel complete for street light controls by digital time switch with connected items fixing on pole/wall/panels including clamp with all fixing arrangements complete including taking down existing switch complete all as specified and as directed.
N Sydeswara Rao
P SRINIVASA RAO
TECHNO SOFT SOLUTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .