Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹46.3 LAccepted-AOC | ₹46.3 L Quoted ₹46.4 L | 1 | Accepted-AOC L1 |
| 2 | 2₹48.7 L+₹2.4 L (5.10%)Rejected-AOC | ₹48.7 L+₹2.4 L (5.10%) | 2 | Rejected-AOC L2 |
Tender Value
₹48.9 L
EMD Value
₹50,000
Closing Date
22 Oct 2022, 6:55 pmClosed
Chief Electrical Engineer
Office of the Chief Electrical Engineer, PWD Electrical Wing, Public Office, Thiruvananthapuram 695003
DEPOSIT-Daily operation SSB-Daily operation of Electrical installation installed in Super Specialty Block of Medical college Hospital Thiruvananthapuram for the period from 1-11-2022 to 31-10-2023.
2022_PWD_516681_1
PWD BLDG TR 6081 2022 6111
Open Tender
Electrical Works
Item Wise
365 days
Medical College Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
19 Jun 2024
15 Oct 2022
26 Oct 2022
15 Oct 2022
22 Oct 2022
15 Oct 2022
15 Oct 2022 - 22 Oct 2022
Amount
Daily operation
OD1191/2022-2023:Supply and providing the following duty staff,having qualifications as mentioned at site for the operation of the existing Substation consisting of 2 Nos. 1000 KVA Transformers, 2 Nos. 750 KVA DG set, HT /LT control Panels and other Electrical installation provided in the Super-speciality Block of Medical college Thiruvananthapuram under the control of Assistant Engineer (Electrical) PWD ,Medical College Section and operating the system as per his direction. The Sub-Station should be operated daily engaging staffs arranged in 3 shifts. The staff requirement in each shift is as follows: 1) Diploma holder in Electrical Engineering certificate to be recognized by Board of Technical Examination Kerala with minimum of 2 years experience. – 1 No. 2) ITI/ITC certificate holder in Electrical/Wireman trade to be recognized by NCVT with minimum of 2 years experience. – 2 Nos. 3) 10th Pass (SSLC or equivalent) and a minimum of 2 years experience in the field of Electrification. - 4 No. ( 3 nos 8 hours shift duty and one day duty in General Shift). The electrical installation shall be operated as detailed in the mode of operation attached separately. The certificates of the operating staff should be produced before the Executive Engineer at time of agreement. The attendance certificates of the staff shall be maintained strictly by the Assistant Engineer concerned . The safety precautions for the operators / staff shall be maintained by the contractor itself and timely verified and report to the Assistant Engineer. Necessary laison work regarding the operating staff in connection with the guidelines of labour department and government and handover to Assistant Engineer from time to time.
OD4570/2022-2023:Supply, following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
OD4571/2022-2023:Supply of Ding dong bell
OD4572/2022-2023:Supply of 6/16A Combined socket Modular Type
OD4575/2022-2023:Supplying a following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD4578/2022-2023:Supplying of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
OD4579/2022-2023:Supplyingof following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
OD4580/2022-2023:Supplying of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
OD4581/2022-2023:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
OD4583/2022-2023:Supplying following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
OD4584/2022-2023:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD4585/2022-2023:Supplying 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD4586/2022-2023:Supplying following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD4587/2022-2023:Supplying following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD4588/2022-2023:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD4589/2022-2023:Supplying following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD4590/2022-2023:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD4592/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
OD4593/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
OD4594/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
OD4595/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
OD4596/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
OD4597/2022-2023:Supplying following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
OD4598/2022-2023:Supplying following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
OD4599/2022-2023:Supplying following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
OD4600/2022-2023:Supply following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
OD4977/2022-2023:Supply of following sizes of medium gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
OD4617/2022-2023:Supply of 300/305 mm sweep Light Duty Exhaust fan in metal frame
OD4618/2022-2023:Supply of 1200mm, 20W LED Tube
OD4619/2022-2023:Supply of 8 module Moulded Plastic boxes
OD4621/2022-2023: Supply of 4 module Moulded plastic boxes
OD4622/2022-2023:Supply of following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
OD4623/2022-2023:Supply of 6A 3 PIN PLUG TOP
OD4624/2022-2023:Supply of 32 A DP switch with indicator modular
OD4625/2022-2023:25 A3 pin shuttered socket modular
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD4632/2022-2023:Supply of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD4633/2022-2023:Supply of Step fan regulator - socket size
OD4634/2022-2023:Supply of 2.25mfd fan capacitor
OD4635/2022-2023:Rubber shackle
OD4636/2022-2023:Split pin / cotter pin
OD4645/2022-2023:Supply angle/straight brass lined skirt type,bakelite batten holder with shade and giving connection etc as required with 5w LED bulb
OD4646/2022-2023:Supply OF following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Vijayabhanu.R
Bidder Name
S.UnnikrishnanNair
Vijayabhanu.R
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_741210.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .