| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹44.3 L+₹22,129.50 (0.50%)Rejected-Finance NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹46.9 L+₹2.8 L (6.42%)Rejected-Finance | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹47.0 L+₹2.9 L (6.60%)Rejected-Finance VIKRAM COACHING GALI SUDAMA NAGARI MADI NATH BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
21 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
PROVN OF RING MAIN LT SYSTEM FOR MH BAREILLY AND PROVISION OF CERTAIN E/M MINOR WORKS UNDER AGE E/M OF GE WEST BAREILLY
2022_MES_561733_2
8081/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST BAREILLY
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹94,000
Yes
28 Feb 2023
2 Feb 2023
23 Feb 2023
2 Feb 2023
21 Feb 2023
9 Feb 2023
Amount
Supply,installing,commissioning and testing of LT feeder panel outdoor type , CPRI certified factory made cubical type weather and vermin proof including ventilation and louvers arrangement with PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel. The panelhave the following electric controls .Insulated epoxy coated high conductivity aluminium bus bar as per specified for phase and neutral with specified space complete all as specified and directed.
(A) Incoming
(i) On load Change Over Switch (TPN)1000 Amp, 415 V, 50Hz -06 No, Make; Legrand, L&T, ABB
(ii) Multi function meter (0- 1000 amp) with all assesories.-03
(iii) LED Indicating lamp assembly R,Y,B Phase – 03 Set
(B) Out Going
(i) ACB 800 Ampere 50 KA, 4 pole, 415 volts 50 Hz with microprocessor based realised – 03 No.Make: Legrand,L&T,ABB
(ii) Multi function meter (0- 1000 amp) with all assesories.-03
(iii) LED Indicating lamp assembly R,Y,B Phase – 03 Set
Note: Panel Must be design as Per Single Line Daigram Attached.
Supply,installing,commissioning and testing of LT feeder panel outdoor type , CPRI certified factory made cubical type weather and vermin proof including ventilation and louvers arrangement with PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel. The panelhave the following electric controls .Insulated epoxy coated high conductivity aluminium bus bar as per specified for phase and neutral with specified space complete all as specified and directed.
Incoming
(i) On load Change Over Switch 1600 Amp,415 V, 50Hz-02 No.Make; Legrand,L&T,ABB
(ii) Multi function meter (0- 2000 amp) with all assesories.-02
(B) Out Going
(i) ACB 1600 Ampere 50 KA, 4 pole, 415 volts 50 Hz with microprocessor based realised – 02 No. Make; Legrand,L&T,ABB
(ii) Multi function meter (0- 2000 amp) with all assesories.-02
Note: Panel Must be design as Per Single Line Daigram Attached.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade LT cable (heavy duty) of size 240 Sqmm, 3½ core XLPE insulated armoured with stranded aluminium conductor including commissioning and testing complete all as specified and directed.
M & L for earthing complete with galvanised iron earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 32 X 6 mm by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed.
M & L for earthing complete with copper earth plate electrode 600 X 600 X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 20 X 3 mm by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 25 mm bore including testing on completion of job complete all as specified and directed.
Supply, fixing and testing of 300 mm sweep Metal body exhaust fan single phase, AC 230/240 volts complete with all accessories and louvers including making electric connection with two single core 0.50 Sqmm size stranded copper conductor cable of suitable length as per site requirement complete all as specified and directed.
S & F of point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.6 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size solid copper conductor cable as in earth wire and connecting all metal parts, to common earth dolly complete all as specified and directed.
M & L for cutting Hole in wall for fixing of exhaust fan of size 250 to 300 mm as required at site and good the disturbed surfaces of wall by using putty and match with existing colour of wall complete all as specified and directed.Note:Cost of repairing work and material (cement and sand) included in quoted rate.
Supply and fixing of switch piano flush button single pole one-way 5 Ampere complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables or foundation of poles and getting out in Soft/loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in each layer as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M & L for fine sand free from sharp materials as in filling in trenches for cable protection including necessary punning and consolidation as required complete all as specified and directed. Note:- Punned thickness of sand shall be measured.
M & L for laying brick as in protection covers over cables using sub class 'B' old size bricks complete all as specified and directed.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade LT cable (heavy duty) of size 10 Sqmm, 4 core XLPE insulated armoured with stranded aluminium conductor including commissioning and testing complete all as specified and directed.
S & F 40 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified and directed.
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant incl ding thermal anagement in multiple optics complete with IP 65/66 protection complete of 120 watt . Bracket made out with GI pipe medium grade not less than 1.2 mtr long and bent to shape incl 02 Nos MS clamps of size 50x6 mm with nut bolt washer complete with connction of street light from pole box to fittings with 1.5 sq mm 3 core copper conductor complete all as spd and directed.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP -22 (8.5 Mtr long) including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately in respective items .
S&F of loop-in-loop out box of size 30x20x20cm made out from 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 04 Nos aluminium bus bar of size 25mm x 2mm-4 Nos fixed on insulator and one MCB of capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts,bolts & washers etc complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type B1 using (20 mm graded aggregate for pole coping complete all as specified and directed.
M & L for earthing complete with galvanised iron earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed.
Supply and fix ceiling Fan with blades and down rod, 230/240V of size 1200mm sweep complete all specified and directed.Note:-Fixing incl modification in GI pipe for connecting of ceiling fan included in quoted rate.
S & F of ceiling rose three phase, PVC / polycarbonate isolated body complete all as specified and directed.
Supply, installation,commissioning of Deep Freezer single phase 240 volt, 50 Hz of Capacity 200/205 Lts complete all as spd and directed. Make- Blue Star.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 130 volt to 250 V with output voltage stablized at 230V accuracy of ±2.5% and of capacity 5 KVA all as specified and directed (Make : BLUE BIRD / SINETRAC/V Guard)
S & F of point wiring 15 Ampere socket outlet point (independent point), controlled by one, one way switch with 4.00 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.6 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 4.00 sqmm size solid copper conductor cable as in earth wire and connecting all metal parts, to common earth dolly complete all as specified and directed.
S&F Switch socket combination 2in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
Supply and fixing Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as spd and directed.
Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as spd and directed.
Supply and fixing Copper strip 20 x 3.15 mm with saddles and fixing screws etc.for roof conductors and down conductors above ground complete all as spd and directed.
Supply and fixing copper strip 32x6 mm with burried in to ground for ring conductor and necessary jointiong work shall be carried out by brazing work complete all as spd and directed.
Supply, fixing and testing of 250 mm sweep PVC body exhaust fan single phase, AC 230 volts, 50 Hz complete with all accessories and louvers including making electric connection with two single core 0.50 Sqmm size stranded copper conductor cable of suitable length as per site requirement complete all as specified and directed. Make-Havells/Crompton/Surya.
M&L cutting of existing window by removing of glass/cutting of frame of suitable size of fixing of exhaust fan including fixing of plyboard of 12 mm thick, painting, packing with wiremess complete all as specified and as directed.
Supply and fix bus bar panel with aluminium strip bus bar cap 50A three phase incl MCCB 63 Amp ,25 KA complete all as specified and directed
Supply and fixing LED flood light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant incl ding thermal anagement in multiple optics complete with IP 65/66 protection complete of 120 watt including fixing arrangement made out by 25 X 6 mm (MS flat bracket) as per site requirment with nut bolt and washer complete connction of flood light from pole box to fittings with 1.5 sq mm 3 core copper conductor complete all as spd and directed.
Supply and laying in trenches / ducts, passing through pipe / fixing on poles 1100 volts grade LT cable (heavy duty) of size 25 Sqmm, 4 core XLPE insulated armoured with stranded aluminium conductor including commissioning and testing complete all as specified and directed.
Supply, installation,commissioning Tower type AC with split units indoor and outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement of Capacity 4.0 TR three phase 415 volt, 50 Hz complete all as spd and directed. Make- Blue Star, LG, Carrier, Daikin.
M&L for sub main wiring with four single core 16.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 16.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. Note :- Four runs of 16 sqmm (FRLS) wiring cable and one run of 16.0 sqmm (FRLS) earting cable along with PVC conduit shall be measured as one unit length.
Supply and fix for Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps complete all as spd and directed.
Supply, installation,commissioning hi wall split units indoor/outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary of capacity 1.5 TR single phase 240 volt, 50 Hz complete all as spd and directed. Make- Blue Star, LG, Carrier.
M&L for sub main wiring with two single core 4.0 Sqmm (FRLS) copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including 4.0 Sqmm (FRLS) PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. Note :- Two runs of 4 sqmm (FRLS) wiring cable and one run of 4.0 sqmm (FRLS) earting cable along with PVC conduit shall be measured as one unit length.
S&F AC modular box with Top plug and MCB 20 Amps incl modular box for mounting etc of cap 20 Amps universal complete all as spd and directed .
Notes:- If any item has erronously been repeated in this schedule and the contractor had quote different rates for the same. In such cases, least quoted rate for whole quantity shall be applicable and the item for which higher rate has been quoted by the contractor, shall not executed at site.
BK CONSTRUCTION
Ishtiaq and Sons
M/s. S.S. Refrigeration, Bareilly
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .