Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.0 CrAccepted-AOC KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L-1 | Accepted-AOC Lowest | |
| 2 | L-2₹1.1 Cr+₹8.1 L (8.00%)Rejected-Finance | L-2 | Rejected-Finance Highest |
Tender Value
₹76.9 L
EMD Value
₹1.5 L
Closing Date
1 Jun 2021, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Division, Hr. PWD B and R Br., Ambala Cantt.
Construction of Office Building for DMER Plot No. IP-1(P) in MDC, Sector-6, Panchkula. (Pdg. E.I Only).
2021_HRY_171637_1
PWD/Elect-KNL/Elect-AMB/110157
Open Tender
Construction Works
Works
180 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.5 L
16 Sept 2021
13 May 2021
2 Jun 2021
13 May 2021
1 Jun 2021
13 May 2021
Amount
( c ) Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 100 amp.to 220 amp.415 V,10 KA 3-phase.HSRNo. 31.12 c (ii)
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm.HSRNo. 31.13(ii)
M.S.Sheet . Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.HSRNo. 31.14 (i)
Blanking sheet . Supply and erection of blanking sheet in existing distribution board.HSRNo. 31.16 (i)
(L) Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.HSRNo. 31.17a) (ii)
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp. HSRNo. 31.17(a) (iii)
(M) Supply and erection of Fittings and Accessories. Supply and erection of rectangular bulk head fitting of size 17 cm x 14 cm, aluminium casted with aluminium colour out side and white stove enamelled inside/complete with guard, glass etc. secured by brass screws suitable upto 100 watts lamp with B.C. lamp holder but without lamp. HSRNo. 31.18 (xx)
Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. HSRNo. 31.18 (xxiv)
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. .HSRNo. 31.18 (xxvi)
(O) Erection and carriage of fans.. Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.HSRNo. 31.20 (i)
Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work.HSRNo. 31.20 (iii)
(P) Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed. HSRNo. 31.21 (xxi)
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed. HSRNo. 31.21 (xxii)
Heavy guage welded conduit pipe 32 mm dia 1.60 mm thickness flushed. HSRNo. 31.21 (xxiii)
(Q) Earthing Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as equired. HSRNo. 31.22(iii)
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. HSRNo. 31.22(v)
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . HSRNo. 31.22(xi)
Pdg. and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required with all labour and material. HSRNo. 31.22(xv)
Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. stapples of same size. HSRNo. 31.22(xix)
(b) Lightning conductor Galvanised iron. Excavation of earth pit 180 cm. round at top and 90 cm. at bottom 4.5 metres deep and refilling the same in hills including supply of necessary charcoal / coke and salt mixture. HSRNo. 31.24 (iii)
Supply and erection of 60 cm. X 60 cm. X 6 mm thick galvanised Iron plate including nacessary bolts and nuts to G.I. tape . HSRNo. 31.24 (iv)
Pdg. Standard watering tank including down pipe and C.I. cover with locking arrangement etc. HSRNo. 31.24 (v)
Supply and erection of 20 mm x 3 mm thick lightning conductor G.I. tape fixed with suitable G.I. stapples of same size. HSRNo. 31.24 (vi)
Supply and erection of G.I. tape 32 mm x 6 mm thick from earth electrode directly in ground and surface , fixed with G.I. stapples of same size. HSRNo. 31.24 (vii)
Supply and erection of 25 mm dia meter 1.5 metre long lightning G.I. tube rod tapered in to a point at the top with 16 cm. X 16 cm x 3 mm thick G.I. base plate and necessary nuts and bolts with washer. HSRNo. 31.24 (viii)
Prioviding and fixing , testing joint made of 20mm x 3mm thick G.I. strips 125mm long with 4 No.s. G.I. bolts and nuits, check nuts with washer complete. HSRNo. 31.24 (ix)
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections . 35 Sq. mm 3.5 Core Cable . HSRNo. 31.26 (xxvi) Ard.
(X) Miscellaneous . Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. 20 mm dia . HSRNo. 31.35 (i) (b)
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 35 sqmm . HSRNo. 31.35 (ix) (f)
(A) PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. Fan Point - Medium .HSRNo. 31.36
Fan Point- Long.HSRNo. 31.36
Light point -Short.HSRNo. 31.36 (ii)
Light Point - Medium.HSRNo. 31.36
Light Point- Long.HSRNo. 31.36
Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell - Long pointHSRNo. 31.36 (vi) c
3 pin 5 amp. plug point including earthing the 3rd. pin etc.- Long point. HSRNo. 31.36 (vii) c
3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated Copper conductor cable - Long point.HSRNo. 31.36 (viii) c
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm (3 / 0.81mm).HSRNo. 31.40 (i)
Size 2.50 sqmm (3 / 1.05mm).HSRNo. 31.40 (ii)
Size 4 sqmm (7 / 0.85mm).HSRNo. 31.40 (iii)
Size 6 sqmm ( 7 / 1.05mm).HSRNo. 31.40 (iv)
Size 10 sqmm ( 7 / 1.35mm).HSRNo. 31.40 (v)
Size 16 sqmm (7 / 1.70mm) HSRNo. 31.40 (vi)
Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 4-way, TP & N (Horizontal) (8+12)HSRNo. 31.41 (iv)
8-way, TP & N (Horizontal) (8+24)HSRNo. 31.41 (v)
12-way, TP & N (Horizontal) (8+36)HSRNo. 31.41 (v)
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material requiredto complete the job in all respect to the entiresatisfaction of Engineer-in-Charge of work. 25 mm diaHSRNo. 31.44(b)
Supply and erection of copper lugs including crimping etc.upto the entire satisfaction of Engineer-in-Charge of work. 1.5 sqmm to 2.5 sqmmHSRNo. 31.45 (a)
4 sqmm to 6 sqmmHSRNo. 31.45 (b)
10 sqmm HSRNo. 31.45 (c)
16 sqmm HSRNo. 31.45 (d)
Providing & fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. 10 amp 1 way switchHSRNo. 31.56 (a)
20 amp switchHSRNo. 31.56 (c )
10 amp socketHSRNo. 31.56 (d)
16 amp socketHSRNo. 31.56 (e)
Fan regulatorHSRNo. 31.56 (g)
Call bell Ding Dong (Monitca)HSRNo. 31.56 (h)
Blinking PlateHSRNo. 31.56 (i)
Pdg and fixing GI concealed sheet metal boxes with inner an outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour & material required for the job complete in all respect. 1 & 2 modulesHSRNo. 31.57(a)
4 modulesHSRNo. 31.57(c )
6 modulesHSRNo. 31.57(d)
8 modulesHSRNo. 31.57(e)
12 modulesHSRNo. 31.57(f)
Supply and erection of PVC pipe ISI marked (Medium) recessed in wall/ceiling etc including the cost of PVC bends inspecion boxes, iron hooks and cement concrete etc complete in all respect upto the entire satisfaction of engineer-in-charge of work PVC pipe of 32 mm diaHSRNo. 31.58 (a)
DSR Items Supplying, installing on wall, testing and commissioning offollowing capacity Air Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. 200 A Isc = 15kA for 1 second DSR No. 3.8.1
315 A Isc = 25kA for 1 secondDSR No. 3.8.2
Supplying, installation, testing & commissioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 200 A 15kA SC for 1 secDSR No. 3.11.1
315 A 25kA SC for 1 secDSR No. 3.11.2
Supply, Installation, Testing & Commissioning of End Cover to complete in all respect upto the entire satisfaction of Engineer in Charge of work. Make-C&S, Schneider, Legrand 250 Amp. NS-1 a)
200 Amp. NS-1 b)
Supply, Installation, Testing & Commissioning of Tap Off Box with MCCB to complete in all respect upto the entire satisfaction of Engineer in Charge of work. Make-C&S, Schneider, Legrand 100 Amp. NS-2 a)
63 Amp. NS-2 b)
S/E of Enclosure for upto 125 Amp. MCCB including all labour and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of work. NS-3
M/S PANJETA ELECTRICALS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .