| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹39.5 L+₹28,591.80 (0.73%)Rejected-Finance 234 PKT 8 SEC 12 SURYODAYA APARTMENT DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance Not the lowest bid | |
| 3 | L3₹39.9 L+₹75,857.80 (1.94%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not the lowest bid |
Tender Value
₹41.3 L
EMD Value
₹82,500
Closing Date
22 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Jamnagar
CWE AF Jamnagar Air force Station Jamnagar Gujarat 361003
CERTAIN WORK SERVICES IN ANNEXED BUILDING OF HANGARS AND CONSTRUCTION OF WORKS STATION AT 6 SQN AT AFS JAMNAGAR NO1
2021_MES_411055_1
81092E8
Open Tender
Civil Works
Lump-sum
180 days
Jamnagar
As per Tender document
7 documents required · 7 mandatory
₹500
GE AF Jamnagar No 1
₹82,500
Yes
8 Mar 2021
9 Jan 2021
23 Feb 2021
9 Jan 2021
22 Feb 2021
8 Feb 2021
60 days
Amount
NOTE: Schedule ‘A’ Part I to IX are under Ser No. 1.00 to 7.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the blue coloured field under Col-6 only.
Lump sum price worked out for BUILDING/ STRUCTURE as listed in Sch `A’ Part I.
Lump sum price worked out for (SITE CLEARANCE, EXCAVATION AND EARTHWORK) as listed in Sch `A’ Part II
Lump sum price worked out for INTERNAL ELECTRIFICATION WORK FOR NEW BUILDING as listed inSch `A’ Part III.
Lump sum price worked out for FOOTHPATH as listed in Sch `A’ Part IV.
Lump sum price worked out for EXTERNAL ELECTRIC SUPPLY as listed in Sch `A’ Part V.
Lump sum price worked out for MISC B&R WORKS as listed in Sch `A’ Part VI.
Lump sum price worked out for INTERNAL ELECTRIFICATION WORK FOR EXISTING BUILDING as listed in Sch `A’ Part VII.
SCHEDULE `A' PART - VII (MISC ITEMS)
M&L for moorum / red bajri filling in floors or paving laid in layers n.exc 15 cm thick, spread, leveled and rammed including watering complete all as directed Engineer-in-charge.
S&F false ceiling of Non asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over and including snap grid fabricated with mild steel galvinsed white powder coated section of size size 32 mm x 15 mm as main Tee & cross Tee, 23 mm x 23 mm as wall angle, in square pattern of grid size 600 mm x 600 mm. Snap grid shall be supported with mild steel galvanised wire hangers of 4 mm dia. adjusting level fixed to roof slabs etc by means of cleats and expansion hold fasteners as per manufacturer instruction complete all as specified directed by the Engineer-in-Charge. Make : Everest or equivalent as approved by GE
M&L for light shade (double charged) colour vetrified ceramic tiles of size 600 mm x 600 mm x 9-10 mm thick, as in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match.
All as per item No 11 above but laying of tiles as in dado / skirting over and including backing coat 10 mm thick in cement mortar 1:4
S&F fully glazed sound proof fixed type window with UPVC (Unplasticised Poly Vinyl Chloride ) outer frame of sectional area 65 mmx58 mm. All outer frames shall be fully reinforced with galvanised steel. Glazing with 12 mm thick tinted toughened double glass (two glass sealed around the edges with an air space between the two to form a single unit). EPDM/ TP gaskets to be used for better sealing and noise reduction. Co extruded beadings to be used for glazing. Locking system shall be Espag (Multi Point) including sliding window with tinted glass shutters in existing opening with fasteners and sealing with silicon sealant as per manufacturer instructions complete. Make:- Fenesta or equivalent make approved by GE
Complete removal of existing treatment from wall including brooming down or steel wire brushing, scraping down smoke soot, mouls, moss and efflorescent salts and treating oil and greasy spots complete all as specified.
M&L for preparation of plastered wall surface including pilaster/cornices etc and applying two coats of acrylic emulison(exterior weather coat) paint of any tint as approved over one coat of primer applied as per manufacturer's instruction
S&F roller blind with aluminium powder coated channel & PVC runners and fabric blinds fixed to window as per manufacture instruction complete. Make: Vista or equivalent make approved by the GE
S&F Vertical blind with aluminium powder coated channel & PVC runners and fabric blinds fixed to window as per manufacture instruction complete. Make: Vista or equivalent make approved by the GE
M&L for granules textured homogeneous wall finishing system consisting of a two component system of dry granules (25 Kgs per pack) made of 92% silica particles coated with fade resistant pigments, 100% acrylic polymer bonding agent (5 Kgs per pack) with the applied thickness of the coating being between 0.8 mm - 1.2 mm to be applied on cured, smooth level plaster without key, as per manufacturer directions, for usages to be applied and approved applicator of the manufacturer as per the directions / supervision of the Engineer-In-Charge, all complete. The above textured coating should conform to surface spread of flame class one of BS 476 : Part 7 : 1971 and pull off strength of the coating to meet JISA 6909 on smooth plastered surface complete all as specified and as manufacturers specifications / instructions. Make : Bakelite Hylam Limited or equivalent make approved by the GE
Supply & Fix 6 mm thick plain, multicavity poly carbonate sheet (coloured) in roof covering, fixed with and including aluminium fillets at joints and aluminium angles at the end, fixed with screws and standard fittings, fixtures and accessories complete all as specified and as per manufacturer's instructions all as specified and directed.
S&F 20 to 25 mm thick Machine cut, both side polished kota stone slab fixed as in shelves or partition under kitchen platform, fixed with cement mortar 1:4 complete.
S&F 75 mm size stainless steel butt hinges medium weight, fixed to chowkhats all as specified and as directed by Engineer-In-Charge.
S&F 100 mm size stainless steel handle (as per sample kept in GE,s office), complete all as specified and as directed.
S&F 25 mm size magnetic catches with Plastic body and striking plate including letting in and fixed complete
S & F Telescopic Channel of size 500 mm (when closed) as per sample kept in GE office
M&L for repairing the edge / corner of Chajja / roof projection and similar work by removing plaster width / girth not exceeding 150 mm and making good with 10 mm thick rendering in cement mortar 1:3 to match with existing surface complete all as specified.
S&F flameproof, weather proof LED tube light fitting, type FLP-WP with LED 1x 18/20 W including integral reflector made of aluminium alloy LM79 , with electronic driver, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed by Engg-in-Charge. Make: Crompton Cat No EXTN1LT8-16/20 or equivalent of make mention in Appx B
Supply and fix flame proof exhaust fan of size 305 mm (12'') sweep 240 V 50 Hz , 1440 RPM single phase heavy duty complete with louver shutter and flame proof wire from ceiling rose to exhaust fan, complete all as specified & directed. Make:- Sudhir Cat No EF/140 or equivalent of make mention in Appx B. Note: - Rate for cutting opening shall be deem to include in the quoted rate against Sch A Part I Item No 1
Supply and fix Flame proof Ceiling fan 1200 mm in aluminium alloy LM 6 Construction , certified by CMRS , Dhanbad for Group I, IIA, IIB, complete all as specified & directed. Make:- Sudhir Cat No CF/193 or equivalent of make mention in Appx B
Supply and fix Flame proof fan regulators in aluminium alloy LM 6 Construction , certified by CMRS, Dhanbad for Group I, IIA, IIB, complete all as specified & directed. Make:- Sudhir Cat No RI/OA/1010 or equivalent of make mention in Appx B
Supply and fix flame proof and weather proof industrial type DBs with various combination of incoming and outgoing MCB suitable for and including (a) 01 No MCB SPN 16 Amps, C type (incoming) (b) 02 Nos MCB SP 10 Amps C type including necessary connection complete.
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & varmin proof, gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specifed and directed & Connisting of the following switchgear:-
(a) Solid aluminium bus bar 300 Amp for phase, 150 Amp for neutral
(b) MCCB with 200 Amps, 25 KA, 4 pole, 415 Volts, 50Hz with earth fault relay (incoming) - 01 No.
(c) MCCB, TPN, 100 Amps, 25 KA, 4 pole, 415 Volts, 50 Hz (Outgoing ) - 03 nos ( 02 working + 01 Spare)
(d) MCB, SPN, 40 Amps, 10 KA, 230 volts (outgoing) - 03 No ( 02 working + 01 Spare)
(e) Multifunction meter Class, 1.0, Three line Bakelite LCD Display with back sealing arrangement , with meter run hour & power on Hour, AVG , Max & total value of Active , reactive & apparent power & span shot of power ( KW) , current (I) , Voltage (V) & PF with programmable CT Ratio of -/5A along with Suitable size core CTs for current sensing Make HPL , Cat Part No NEMFVIFPPE000 or equivalent of Make : L & T / Secure / Conserve
(f) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set Make : L & T/Secure/Conserve
Item No 30 Contd….... Note:- Bottom of Panel shall be kept 1200 mm above from natural grounf level by providing PCC block masonry plinth with PCC block of mix 1:5:8 & plastering 10 mm thick in CM 1:6 complete all as specified and directed by Engg-in-Charge.
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Item No 31 Contd….... Note:- Quoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 mm x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Item No 32 Contd….... Note:- Quoted rates shall be deem to include for earth strip with protection pipe up to 7.5 M length.
Material and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to copper strip of size 20 mm x 3 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Item No 33 Contd….... Note:- Quoted rates shall be deem to include for earth strip with protection pipe up to 7.5 M length.
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size of 75 mm x 75 mm x 25 mm drilled and screwed with 3 Nos 8 mm dia 25 mm long screw, fixed in and including SMC junction box of size 170 x 170 x105mm hinged door fixed on wall complete all as specified and as directed.
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:-
(i) Refrigerent - R-410 A (Non CFC)
(ii) EER - min 3.5 w/w (5 star rating)
(iii) Tonnage - 1.50
(iv) Indoor Noise Level - Not more than 48 Db
(v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter
Item No 35 Contd….... (vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make: Carrier/ Hitachi/ O General / Blue Star
Note:- Following will be inclusive in rate:- (a) Refrigerant piping length upto 10 mtr will be inclusive in item (b) Installation will include fixing the outdoor unit on wall mount bracket as per direction of Engineer in Charge (c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) Contractor will provide warranty of 5 years for compressor from the date of completion (f) Contractor shall provide complete free service in warrenty period by the company
Voltage stabilizer of automatic operation single space naturally air cooled indoor type and designed for following features Make: V guard/ Daikin/ Bluestar (a) Capacity : - 4 KVA (b) Working Voltage Range - 130 V-280V AC (c) Salient features :- (i)Intelligent time delay system 3 min (ii)Compatible with regular and inverter AC (iii)Wall mounting cabinet design (iv)Low and high voltage cut off (v)Digital display
Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location (within AF station Jamnagar), refixing of same AC at new location complete all as directed by Engr-in-Charge & detail as under:-
(a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.
(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer.
(c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface.
(d) concealing of refrigerant pipe with PVC flexible pipe.
(e) Rate quoted shall be inclusive of Refrigerant gas requirement (R-22)
Taking down carefully by unscrewing old unservicable main switch boards / cut out boxes / MCB DBs / complete sealing the cable end and making good disturbed surface of walls etc.
Material & Labour for three phase sub main wiring with three run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit not less than 25 mm dia and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) as earth wire, fixed concealed in wall / ceiling complete. Note: (i) Three Runs of main cable and one run earth wire with conduit will be measured as one RM for payment. (ii) Cutting chases for concealed wiring will be measured & paid separately under Sch A part VII
Supply and fix Energy efficiency recessed mounted LED luminaire 34 W suitable for 600 x 600 mm grid ceiling along with flat diffuser, constant current electronic driver all as specified and directed by Engg-in-Charge. Make:- Havells Cat No PLUTONE O2X2PLR34WLED857S or equivalent make mention Appx B
Supply and fix wall mounted fan 450 mm sweep, 230 V 50 Hz, with all connected accessories, fixed as per manufacturer's intruction and connecting complete all as directed. Make:- Havelle Airboll Hi-Speed or equivalent make mention Appx B
S&F Distribution board made out of sheet metal powder coated, factory made, enclosure, vertical double door type, TPN 4 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, including 1 Nos Incomer MCCB 63 Amp, triple pole and neutral, 415 Volts, 16 kA breaking capacity, fixing of DB flush to wall surface complete all as specified and directed by Engg-in-Charge.
Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCCB 40 Amp, Four Pole, breaking capacity 10 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix MCCB 63 Amp, Four Pole, breaking capacity 10 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Extra over item No 2, 3, 4, 5, 5A & 6 of Sch A Part VI for removal of debris to a distance exc 1.5 Km but n. exc 5 Km, beyond the lead included in the rates, including loading, unloading and stacking at the destination Note:- (i) Payment shall be made for Actual quantity measured For item No 2 & 3 multiplied by thickness (actual observed at site). (ii) Payment shall be made for actual quantity Measured vide item No 4, 5, 5 A & 6. .
Supply fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) three track window ( two shutters glazed & one shutters wire gauge) with frame, glazed with 4 mm thick tinted glass and supply and fixing wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below, complete all as specified and directed.
(a) Frame (top & side) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20831) (b) Frame (bottom) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20832) (c) Top & side Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55mm (Section No 20738) ................
Item no 46 Contd .......... (d) Shutter Interlock Section shall be be of size 18.00 x 40.00 x 1.45mm (Section No 20737) (e) Bottom Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55mm (Section No 20736) Note:- Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx B to PS
RACON CONSTRUCTION
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .