| Sl No | Description | Qty | Unit | jayaprakash L6 | PRADEEP M D L3 | KARTHIKEYAN CK L2 | PradeepkumarV L5 | Jaiju Jayaprakash L1 | Lalu.P.R L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00ceiling | |||||||||
| 1.00 | 12.45.1:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1 :2011 (Board with BIS certification marks) | 240 | sqm | 1,372 ₹3,29,280 | 1,200 ₹2,88,000 Lowest | 1,208.57 ₹2,90,056.8 | 1,342.79 ₹3,22,269.6 | 1,333.59 - | 1,327.84 ₹3,18,681.6 |
| 1.00 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 550 | kg | 179 ₹98,450 | 175 ₹96,250 | 157.32 ₹86,526 Lowest | 174.78 ₹96,129 | 173.58 - | 172.83 ₹95,056.5 |
| 1.00 | OD349122/2025-2026:Engaging man coolies for different types of works | 8 | Day | 1,033 ₹8,264 | 1,000 ₹8,000 | 910.11 ₹7,280.88 Lowest | 1,011.19 ₹8,089.52 | 1,004.26 - | 1,000.51 ₹8,004.08 |
| 1.00 | OD353335/2025-2026:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch
ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness
with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy
primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have
protective guard film of 25 microns minimum to avoid scratchesduring transportation and
should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet
shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal,
complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins,
rafters and trusses and including cutting tosize and shape wherever required. | 35 | sqm | 593 ₹20,755 | 650 ₹22,750 | 522.35 ₹18,282.25 Lowest | 580.36 ₹20,312.6 | 576.38 - | 573.9 ₹20,086.5 |
| 1.00 | OD353337/2025-2026:Ridge caping with pre galvanised steel sheets .5mm thick 60 cm wide including all cost and material conveyance labour charge etc complete | 7 | metre | 670 ₹4,690 | 650 ₹4,550 | 590 ₹4,130 Lowest | 655.52 ₹4,588.64 | 651.03 - | 648.22 ₹4,537.54 |
| 1.01 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | 127.5 | kg | 185 ₹23,587.5 | 170 ₹21,675 | 163.38 ₹20,830.95 Lowest | 181.53 ₹23,145.08 | 180.28 - | 179.51 ₹22,887.53 |
| 1.01 | 51.18.12.7:Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately) <br> External work - 65 mm nominal dia | 13.2 | metre | 785 ₹10,362 | 750 ₹9,900 | 690.44 ₹9,113.81 Lowest | 767.11 ₹10,125.85 | 761.86 - | 758.58 ₹10,013.26 |
| 1.01 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.38 | cum | 8,820 ₹3,386.88 | 5,000 ₹1,920 Lowest | 7,767.44 ₹2,982.7 | 8,630.09 ₹3,313.95 | 8,570.98 - | 8,534.04 ₹3,277.07 |
Tender Value
₹5.2 L
EMD Value
₹13,056
Closing Date
1 Nov 2025, 1:00 pmClosed
AMBILI I B
OFFICE OF ASSISTANT ENGINEER LDEW SECTION NATTIKA
Annual Plan-NATTIKA GP 2025-26, PROJECT NO.250/26, FAMILY HEALTH CENTRE MAINTENANCE SECOND PHASE-fhc-General Civil Work
2025_LSGD_814761_2
08/AE/LID EW/NTK/TR/25-26
Open Tender
Civil Works - Buildings
Item Rate
NATTIKA GP
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,155
Yes
₹13,056
Yes
16 Nov 2025
25 Oct 2025
3 Nov 2025
25 Oct 2025
1 Nov 2025
25 Oct 2025
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1363227.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
affi.pdf
Tender Documents • 0.24 MB
pre.pdf
Tender Documents • 0.26 MB
fot.pdf
Tender Documents • 0.25 MB
epay.pdf
Tender Documents • 0.24 MB
integrity.pdf
Tender Documents • 0.23 MB
viewsbd.pdf
Tender Documents • 1.79 MB
BOQ_1363227.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .