Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.4 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | 1 | Accepted-AOC L1 | |
| 2 | 2₹3.5 L+₹5,236 (1.51%)Rejected-Finance | 2 | Rejected-Finance L2 |
Tender Value
₹4.5 L
EMD Value
₹8,950
Closing Date
23 Sept 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EX. ENGINEER (ELECT)-IV/KBZ
OFFICE OF THE EX. ENGINEER (ELECT)-IV/KBZ TOURIST CAMP SITE, J.L. NEHRU MARG, DELHI-02
Improvement /Development of Electric and other allied Work at M and CW Center Naiwalan
2023_MCD_167985_1
MCD/TR/6660/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
60 days
Karol Bagh
5 documents required · 5 mandatory
₹590
₹8,950
19 Oct 2023
18 Sept 2023
25 Sept 2023
18 Sept 2023
23 Sept 2023
18 Sept 2023
Amount
Improvement /Development of Electric & other allied work at M&CW Center Naiwalan
OD10256/2023-2024:Wiring for light/fan point/exhaust fan point call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recess medium class PVC conduit with modular switch, modular plate,suitable size GI box and earthing the point with 1.5sqmm FR PVC insulated copper conductor single core cable etc as required. Group C
OD10255/2023-2024:Wiring for light / power plug with 2 X 4 sqmm FRLSPVC insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no 4sqmm FRPVC insulated copper conductor single core cable for loop earthing as required.
OD10254/2023-2024:Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
OD10257/2023-2024:Rewiring for light point/fan point/exhaust point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as reqd.
OD10258/2023-2024:S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduit as reqd.(a) 3x2.5 sq mm
OD10259/2023-2024:S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduit as reqd.(c) 6X2.5 sq mm
OD10292/2023-2024:S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduit as reqd.(d) 3X 6 sq mm
OD10293/2023-2024:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.(b) 25 mm
OD10294/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
OD10295/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
OD10296/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
OD10297/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
OD10298/2023-2024:Supplying and fixing following size GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm)
OD10299/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as reqd. Upto 450 mm sweep
OD10300/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
OD10301/2023-2024:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
OD10302/2023-2024:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole and Neutral
OD10303/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (b) 63 amps
OD10304/2023-2024:Supplying and fixing following rating, Two pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 40 Amp.
OD10305/2023-2024:Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required
OD10306/2023-2024:P & F 6SWG dia GI wire on surface or in recess for loop earthing as required.
OD10307/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open as required. upto 35 sqmm
OD10308/2023-2024:Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of size not exceeding 25mm2 on surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
OD10309/2023-2024:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD10310/2023-2024:Supply of 15" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as reqd.
OD10311/2023-2024:SITC of single phase monoblock pump set complete with all accessories workable on 240 / 415 Volt 50 Hz AC Supply (a) 1 hp (0.75kW) single phase pump set head from 12-30 metre suction and delivery 25x25 mm
OD10315/2023-2024:Providing and fixing ABC (Aluminium Phosphate) Power type fire extinguisher of 6 Kgs capacity Complete in all respect with ISI mark i/c fixing arrangement etc as required.
Improvement /Development of Electric & other allied work at M&CW Center Naiwalan
122.2.126:SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
122.2.90:Leak detection plugging thereof, complete with reprocessing dehydration and gas charging in 2 Ton Split AC's
122.2.92:Providing and installation of fan in 2 Ton Split AC's Unit
122.2.89:Providing and installation of Outdoor copper condenser coil in 2 Ton Split Unit
122.2.93:Repair of PCB circuit for 2 Ton Split AC's Unit
122.2.77:SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
122.2.125:SITC of 40AH 12 Volt lead acid battery with rack etc. as requrired with four years comprehensive maintenance after one year defect laibility period and battery cost in 3rd year.
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.176:Supplying & Installation of Hot Cold & Normal Floor Standing Top Loading Water dispenser with Cooling Cabinet Fridge cold water storage capacity up to 3.5 ltr with hot water storage capacity up to 1 ltr as required.
122.2.111:supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.1:P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 300x200x105mm (NS) and outer dimension of 333X233X150 mm high dome complete with suitable arrangement for fixing of 4 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
122.2.135: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2*1.0 sq mm
KAFIL ELCTRICAL WORKS
Bidder Name
M/S. A.K. Electricals
KAFIL ELCTRICAL WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .