Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.3 L+₹34,449.56 (1.50%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹23.9 L+₹99,822.13 (4.35%)Rejected-Finance 00 CHAH KATHAUTI CHAH KATHAUTI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹24.0 L+₹1.1 L (4.71%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹24.9 L+₹1.9 L (8.44%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
24 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
PROVISION OF TWO NOs LOW BUDGETED WORKS UNDER GE I NAVY JAMNAGAR
2020_MES_383254_1
8454
Open Tender
Civil Works
Item Rate
180 days
GE I NAVY JAMNAGAR
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹60,000
Yes
20 May 2021
3 Oct 2020
26 Oct 2020
3 Oct 2020
24 Oct 2020
12 Oct 2020
3 Oct 2020 - 10 Oct 2020
60 days
Amount
Surface excavation not exc 30 cmm deep and averaging 15 cm deep & geeting out in soft/loose soil complete all as directed.
Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole, laying of cables, stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in soft / loose soil.
Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole, laying of cables, stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in hard/ dense soil.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 Mts and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified. (Measurements shall be taken after compaction).
M&L broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
Cutting holes in brick works of size not exc half brick built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required including making good as per its original specification with out any extra cost complete all as directed.
M & L for PCC 1:2:4, type B2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
M & L for PCC 1:4:8, type D2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
M&L pre cast PCC 1:3:6 type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:4 complete all as specified.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in foundation , including rafts, footings, foundation beams, plinth beams, base of columns etc and the like complete. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) square or rectungular as in Columns, pillars, piers, posts and struts and the like complete. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in beams, cantilevers, bressummers lintels over 1.5m span complete all as directed.. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in chajja complete all as directed.. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 ( using 20mm graded crushed stone aggregate) as in slabs supported on walls , beams and columns in floors, roofs, landings, canopies, deck slab etc complete all as directed. .Note: Reinforcement shall be measured and paid separately.
Supply only Integral Water Proofing Compound (ISI Marked)of Make : CICO , Acco Proof , Impermo , Aqua flex as approved.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or batter, circular/curved, rough finished surface all as specified.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or batter, flat rough finished surface all as specified.
Formwork to chullah hoods, chajjas, troughs and similar items including edges, flat rough finished surface all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping), flat rough finished surface all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat rough finished surface all as specified.
Formwork to curved /circular soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.rough finished surface all as specified.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions in square, rectangular on polygonal, rough finished surface all as specified.
Formwork to surface of concrete , circular on plan ,sides of pillars, posts, struts, piers, columns and stanchions in circular rough finished surface all as specified.
S&F Second class hard wood factory made kiln - seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as directed.
S&F 35 mm thick second class hard wood factory made plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as directed.
S&F 30 mm thick second class hard wood factory made glazed and skeleton shutter open rebated and prepared to receive glass, guage etc edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc for windows and ventilator as specified in SSR Part I Section 8 clause 8.24 (b) supplied and fitted to chowkats.
S&F 75 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S & F 125 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S & F 150 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 125 mm size aluminium alloy handles (ISI Marked) cast type anodised and fixed.
S&F 150 mm size aluminium alloy handles (ISI Marked) fabricated type anodised and fixed.
S&F 250 mm long aluminium alloy, anodised sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S&F 125 mm long aluminium plate type II gate and shutter, hooks and eyes.
M&L mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S&F mild steel plate for for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe 290 Gde E-165 complete all as specified and directed.
S & F Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5cm long ( Diameter of neck 16 to 20mm) complete all as directed.
S&F rolled mild steel section as in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. of gde Fe-290 grade E-165 complete all as specified and directed.
S & F 10 mm dia and over TMT bars cut to length bent to shape required cranking including bending , hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No. 41 here-in-above but 6 to 8mm dia bar - do -
All as per item No. 41 here- in – above but 5 mm dia and over upto 10 mm dia as in stirrups
Material and labour for prepration of surface over roof slab and cleaning of surface with wire brushes and water removing of unsolvent materials and depositing of the same as directed at a distance not exceeding 50m and provide 15 mm thick screed bed/ bedding layer in CM 1:3 mixed with Water Proofing Compound (WPC) as per manufacturer instructions, including finishing the surface fair and even on RCC roof/ parapet once bedding layer of concrete is completely dried and apply oil bound bituminous primer @ 0.30 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure as directed and finally finished the top surface with two coats of thermal resistant paint complete all as specified and as directed. Note: (i) The quoted rate is deemed to be inclusive preparation of roof surface complete , 15 mm thick 1:3 screed & complete APP treatment. (ii) WPC will be paid seperately (iii) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT (iv) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M&L 100 mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed granite stone aggregate) as in sub base, floors, pavings etc. finished fair and even complete all as specified.
M & L for 75 mm thick plain cement conctere 1: 3 : 6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection finished the surface fair and even complete all as directed.
M&L 75 mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed granite stone aggregate) as in sub base, floors, pavings etc. finished fair and even complete all as specified.
M&L for 40 mm thick plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in floor and finished finished fair and even without using extra cement complete all as directed.
M&L for machine cut kota stone slab of minimum size 550 x 550mm, 18-20 mm thick, as in floor laid over and including 15 mm thick screed bedding in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & mirror , polishing complete all as directed.
All same as per item No. 49 here - in - above but as in dado & skirting with 10 mm thick 1 : 4 cement mortar screed - do - (Note for item No 49 & 50 : i) Quoted rate is deemed to be inclusive of cement screed.)
M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with WPC as per manufacturer instruction, and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC measured and paid separately).
M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified.
M&L for rendering 5 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified.
M&L Three coats of white wash on newly plastered surface of walls after necessary preparation of surface complete all as directed.
M&L Three coats of white wash on newly plastered surface of ceiling after necessary preparation of surface complete all as directed.
M&L preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as directed.
M&L preparing new plastered wall surfaces and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified.
M&L preparing new plastered ceiling surfaces and applying two coats of oil emulsion distemper complete all as specified.
M&L preparing newly plastered or unplastered surfaces of exterior walls and applying two coats of antifungal exterior emulsion weather proof paint (Apex) of colour/ tint over a coat of alkali resistant primer complete all as specified.
S & F 4 mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads in square not exc. 0.5 sqm in each pane complete all as directed.
M & L Two coats of 1st quality synthetic enamel paint over a coat of pink primer on new wooden surface of any description over 10 cm in width or girth including necessary preparation of new wooden surface complete all as directed.
M & L Two coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surface complete all as directed.
M&L forming Construction (Dummy) joints 30mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as directed.
M&L for point wiring with 1100V grade with FRLS 1.5 Sqmm single core PVC insulated cable, copper conductor multistranded passing through and including PVC concealed 20 mm dia conduit and conduit accessories with concealed MS/ PVC Box and logic modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 sqmm as earth wire connected to common earth dolly as specified for one light / fan point controlled by one switch complete all as directed. Note : (1) Rate include cost of cutting wall / floor / ceiling and making chasses and MS box in concealed for cutting and sinking for boxes and making good to walls, no extra payment will be made for the same. (2) Switch and socket shall be measured and paid separately.
All as per item No. 64 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified.
All as per item No. 64 here-in-above but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified.
All as per item No. 64 here-in-above but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F in repairs switch modular type single pole one way 6 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs switch modular type single pole one way 16 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 11 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet 3 Pin 6 Amp modular type all accessories complete all as directed. Make: Legrand Cat No. 6755 52 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet multipurpose 2/3 Pin for 6 / 16 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 55 or equivalent in Philips / Crabtree / ABB / Havells
S & F Ceiling rose surface bakelite White / Ivory / Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
S & F sheet metal enclousure SPN DB 230 Volts , AC , 8 Way with 200 Amps rated bus bar with double door locking system complete . Make : Legrand Cat No 507621 / Havells / L&T /ABB
S&F MCB SP 6, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 87 / Havells / L&T / ABB
S&F MCB SP 16, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 92 / Havells / L&T / ABB
S&F MCB SPN 32 Amp, 50 Hz, AC supply, 10 kA with proper size lugs. Make: Legrand Cat No. 4086 17 or equivalent of Havells / L&T / ABB
S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X020XC 20 W CCT 6500 or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
S&F new LED street light 45 Watt in aluminium pressure die cast housing and clear injection moulded polycarbonate/ toughene glass (IP 65 protection) having multi chip on board LED and metal clad PCB. The minimum lumen output of the system shall be greater than 4000 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing on bracket including nut bolts, 2.5 Sqmm, 3 core cable and electrically connected fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar / Bajaj / Crompton / Philips / Wipro/ Havells.
Supply and lay cable in trenches or fixing on wall or pole XLPE cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (heavy duty) with standard aluminium conductor 1100 volt grade cross sectional area 10 Sqmm 2 core. making necessary connection & testing on completion all as directed.
S&F 25 mm bore high density polyethylene pipes ISI Marked (HDPE) of pressure rating 6 kgf/cm2 for protection of cable in trenches complete as specified.
Supply and laying in trenches or fixed on wall/ pole 40 mm bore galvanised steel water tubing light grade with fittings such as bends, tees, elbows, nipples, unions, short pieces etc making necessary connection and testing on completion all as specified and directed.
S&F Ceiling fan 1200 mm sweep, 230 V including fan regulator with down rod and making connection from ceiling rose to fan with 3 core 1.5 Sqmm copper conductor of any length wih all accessories as ordered making necessary connection as per manufacxturers instructions and testing on competion all as directed.Make ; Bajaj Model No : Energy Smart 50 1200 mm White C/F (Code-251086) or equivalent of Usha / Ketan /Havels.
badri glass and construction
1R K Traders
M/s.Bhavin Electricals
JAMNAGAR ELECTRIC AND MACHINERY CO
Magnus Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .