Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC TC 25664 RAJI OPP HOTEL AMRITHA THYCAUD THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L1 | Accepted-AOC L1 |
Tender Value
₹5.3 L
EMD Value
₹13,326
Closing Date
24 May 2025, 6:00 pmClosed
AEE PWD ELE SUB DVN TVM
PWD ELE SUB DVN TVM
DEPOSIT-Electrical Renovation of Radiology Room in Dental Collage -Air Conditioning of Radiology Room for Department of Oral Medicine and Radiology Government Dental Collage Thiruvananthapuram -Electrical AC Work
2025_PWD_762031_2
ESDT/ET 15/2025-26
Open Tender
Electrical Works
Item Rate
60 days
PWD ELE SUB DN TVPM
please refer tender documents
6 documents required · 6 mandatory
₹1,175
₹13,326
23 Jul 2025
19 May 2025
26 May 2025
19 May 2025
24 May 2025
19 May 2025
Amount
Air Conditioning
OD5002/2023-2024:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/ Bluestar:- 1.0TR single phase Inverter split A/C unit
OD5003/2023-2024:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/ Bluestar:- 1.5TR single phase Inverter split A/C unit
OD5004/2023-2024: Supply and installation testing and commissioning of 2 TR ,3 star rated High Wall Inverter split A/C unit with cut out type, Super quiet (Sound less than 40 db) with capable of operation on long mode to make air flow up to 12 m , computerized demystification, 5 step vane controlled swing , operating on suitable R410 refrigerant with copper material coil used condensing and evaporating units capable for cooling, microprocessor control with cordless remote control, having 5230 full load output wattage including etc. The indoor and outdoor unit fixed on wall or suitable place (G+1)with suitable size factory made metal stand, supply and clamping insulated copper pipe and control /power cable(minimum 3mt max) and giving connection as required and testing and commissioning entire unit . Make ,Blustaer / Voltas / Carrier
OD14681/2025-2026:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit of tonnage 3.0 TR or cooling capacity 10550W, with minimum ISEER of 3.6, single phase split type AC unit conforming to IS fitted with inverter rotary compressor, 100% inner grooved copper tubes operating on 230V single phase AC supply, R32 /non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc with comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete.(Carrier/Blue star/Daikin/LG/Mitsubishi or equivalent)
OD5001/2023-2024:Supply and Fixing of 3 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 250V (make V-GUARD or its equivalent
OD5007/2023-2024:Supply and Fixing of 4 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V (make V-GUARD or its equivalent
OD5006/2023-2024:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 250V (make V-GUARD or its equivalent
OD5012/2023-2024:Supply and installation for the Outdoor unit stand of Single phase 1 TR/1.5 TR/2TR Wall mounting split A/C unit.
OD5011/2023-2024: Supply & Installation of Heavy Duty Stand for Air Conditioning Outdoor Units
OD5009/2023-2024:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
OD5010/2023-2024:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge
OD5008/2023-2024:Supply and fixing 25mm dia PVC drain pipe and along with all required accessories in suface/recess including cutting the wall and making good the damages etc as required
OD5013/2023-2024: Dismantling the existing single phase 1TR/1.5TR/2TR A/C units, re-install the same in to another location without any damage and make the unit in presant working condition.
OD5014/2023-2024:Charges for dismantling the existing Air Conditioner making good the damages of wall and conveying dismantled materials to section store 1 TR, 1.5 TR, 2 TR and 3TR.
OD5015/2023-2024:Painting letters or figures of the 2.50 cm,4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, Panel board etc...as requeued.
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
Bidder Name
Seven Seas Infotech Systems
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1246855.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .