| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.5 LAdmitted-Finance 612 CHIRANJIV TOWER 43 NEHRU PLACE NEHRU PLACE NEW DELHI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | ₹58.5 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Non compliance of NIT clause No 16C |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non compliance of NIT clause 16D |
| Sl No | Description | Qty | Unit | IRC Engineering Services India Pvt. Ltd. L1 |
|---|---|---|---|---|
| 1.00 | Ultrasonic flaw detection of weldments on Towers, Tanks, Equipment, nozzles, Large dia gas lines and Process Pipe Lines as per standard practice using reputed make UT flaw detector probes by ASNT/ISNT UT level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data and submission of reports. | 1,800 | Inch Dia | 210 ₹3,78,000 Lowest |
| 2.00 | Ultrasonic flaw detection of weldments on Towers, Tanks, Equipment, nozzles, Large dia gas lines and Process Pipe Lines as per standard practice using reputed make UT flaw detector probes by ASNT/ISNT UT level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data and submission of reports. | 500 | Running meter | 760 ₹3,80,000 Lowest |
| 3.00 | Thickness measurement/mapping with grid marking at identified locations of XU towers/tanks and piping using standard UT thickness gauges and probe by ASNT/ISNT UT Level II/III qualified and experienced persons including surface preparation with pre/ post cleaning, interpretation of data and submission of reports. | 75,000 | No of spots | 20 ₹15,00,000 Lowest |
| 4.00 | Phased Array Ultrasonic Testing/Time of flight diffraction of weld joints of Exchange Unit towers / tanks /pipelines as per standard practice using standard equipment and probes by ASNT/ISNT UT Level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data, preparation and submission of reports . | 50 | Running meter | 5,000 ₹2,50,000 Lowest |
| 5.00 | Liquid Penetrant Testing of weldments of heat exchangers, stiffening rings, equipment skirt/saddle supports, equipment nozzles d of XU Towers, tanks and weldments of pipe lines (including supply of consumables and DP kit) by ASNT/ ISNT LPT level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments and submission of reports | 7,000 | Inch Dia | 45 ₹3,15,000 Lowest |
| 6.00 | Liquid Penetrant Testing of weldments of heat exchangers, stiffening rings, equipment skirt/saddle supports, equipment nozzles d of XU Towers, tanks and weldments of pipe lines (including supply of consumables and DP kit) by ASNT/ ISNT LPT level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments and submission of reports | 500 | Running meter | 660 ₹3,30,000 Lowest |
| 7.00 | Long Range Ultrasonic testing (LRUT) of process liquid piping and Large dia Gas piping connected to tower and tank with in 1st isolation valve of size from 4 Inch NB to 36 Inch dia. | 9,000 | Running meter | 300 ₹27,00,000 Lowest |
Tender Value
₹67.6 L
EMD Value
₹1.4 L
Closing Date
8 Aug 2025, 2:30 pmClosed
GM HWPK
heavy water plant kota, anushakti via kota
Non-Destructive Examination of various equipments and process piping at HWPK site during MTA-2025
2025_HWB_867494_1
HWPK/MECH/ISI/MTA-2025/431A
Open Tender
Machineries/ Mechanical Engg Items
Works
60 days
heavy water plant kota, anushakti via kota
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.4 L
gm office hwpk
28 Oct 2025
5 Jul 2025
14 Aug 2025
5 Jul 2025
8 Aug 2025
10 Jul 2025
30 Jul 2025
Amount
Ultrasonic flaw detection of weldments on Towers, Tanks, Equipment, nozzles, Large dia gas lines and Process Pipe Lines as per standard practice using reputed make UT flaw detector probes by ASNT/ISNT UT level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data and submission of reports.
Ultrasonic flaw detection of weldments on Towers, Tanks, Equipment, nozzles, Large dia gas lines and Process Pipe Lines as per standard practice using reputed make UT flaw detector probes by ASNT/ISNT UT level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data and submission of reports.
Thickness measurement/mapping with grid marking at identified locations of XU towers/tanks and piping using standard UT thickness gauges and probe by ASNT/ISNT UT Level II/III qualified and experienced persons including surface preparation with pre/ post cleaning, interpretation of data and submission of reports.
Phased Array Ultrasonic Testing/Time of flight diffraction of weld joints of Exchange Unit towers / tanks /pipelines as per standard practice using standard equipment and probes by ASNT/ISNT UT Level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments, interpretation of data, preparation and submission of reports .
Liquid Penetrant Testing of weldments of heat exchangers, stiffening rings, equipment skirt/saddle supports, equipment nozzles d of XU Towers, tanks and weldments of pipe lines (including supply of consumables and DP kit) by ASNT/ ISNT LPT level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments and submission of reports
Liquid Penetrant Testing of weldments of heat exchangers, stiffening rings, equipment skirt/saddle supports, equipment nozzles d of XU Towers, tanks and weldments of pipe lines (including supply of consumables and DP kit) by ASNT/ ISNT LPT level II/III qualified and experienced persons including surface preparation with pre/post cleaning of weldments and submission of reports
Long Range Ultrasonic testing (LRUT) of process liquid piping and Large dia Gas piping connected to tower and tank with in 1st isolation valve of size from 4 Inch NB to 36 Inch dia.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .