| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-Finance | ₹12.5 L | L1 | Accepted-Finance Qualified |
| 2 | L2₹13.0 L+₹46,803 (3.74%)Accepted-Finance | ₹13.0 L+₹46,803 (3.74%) | L2 | Accepted-Finance Qualified |
| 3 | L3₹14.7 L+₹2.2 L (17.9%)Accepted-Finance 425 THE GOLDEN SQUARE CHANDIGARH ROAD ZIRAKPUR ZIRAKPUR PUNJAB 140603 | S A S NAGAR | PUNJAB | 140603 | ₹14.7 L+₹2.2 L (17.9%) | L3 | Accepted-Finance Qualified |
| 4 | Not Admitted-Fee/PreQual/Technical B 69 SECTOR 65 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | QUANTEK AGRO SCIENCE L2 | EARTH AGRO STRUCTURES PVT LTD L3 | Tushar Goel L1 |
|---|---|---|---|---|---|---|
| 1.00 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:
All kinds of soil | 231 | sqm | 180 ₹41,580 | 211.2 ₹48,787.2 | 127 ₹29,337 Lowest |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.: All kinds of soil. | 155 | cum | 400 ₹62,000 | 576 ₹89,280 | 227 ₹35,185 Lowest |
| 3.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) | 7 | cum | 5,500 ₹38,500 | 5,760 ₹40,320 | 4,927 ₹34,489 Lowest |
| 4.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 8 | cum | 9,800 ₹78,400 | 7,936 ₹63,488 | 6,927 ₹55,416 Lowest |
| 5.00 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.: Electric resistance or induction butt welded tubes | 2,302 | kg | 145 ₹3,33,790 | 134.4 ₹3,09,388.8 | 127 ₹2,92,354 Lowest |
| 6.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 27 | cum | 800 ₹21,600 | 460.8 ₹12,441.6 | 127 ₹3,429 Lowest |
| 7.00 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) | 9 | cum | 8,500 ₹76,500 | 8,576 ₹77,184 | 7,227 ₹65,043 Lowest |
| 8.00 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement : 6 fine sand) | 44 | sqm | 400 ₹17,600 | 416 ₹18,304 | 327 ₹14,388 Lowest |
| 9.00 | Providing and fixing tripple wall Polycarbonate sheet, 10 mm thick, multi UV protected, of make LEXAN/MACROLON or equivalent, in roof upto any pitch, including fixing. The sheet shall be fixed using self drilling/self tepping screws with EPDM seal including Aluminium profiles and EDPM gaskets on joints. The cost of Aluminium profiles shall be paid separately. Aluminium tape on free ends of sheet to be applied to prevent ingress of moisture in sheet. All joints to be sealed with Silicon of approved quality. | 132 | Sqm | 1,350 ₹1,78,200 | 960 ₹1,26,720 Lowest | 2,027 ₹2,67,564 |
| 10.00 | Providing and fixing double wall Polycarbonate sheet, 8 mm thick, multi UV protected, of make LEXAN/MACROLON or equivalent, in roof upto any pitch, including fixing. The sheet shall be fixed using self drilling/self tepping screws with EPDM seal including Aluminium profiles and EDPM gaskets on joints. The cost of Aluminium profiles shall be paid separately. Aluminium tape on free ends of sheet to be applied to prevent ingress of moisture in sheet. All joints to be sealed with Silicon of approved quality. | 99 | Sqm | 1,250 ₹1,23,750 | 896 ₹88,704 Lowest | 1,727 ₹1,70,973 |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
14 Oct 2025, 12:00 pmClosed
Superintending Engineer
ESU CSIR-IHBT Palampur
C/o Green House under Project GAP-352
2025_CSIR_249971_1
5-385/WS/2025
Open Tender
Civil Works
Item Rate
120 days
CSIR-IHBT Palampur
2 documents required · 2 mandatory
₹500
Director
₹30,000
17 Dec 2025
22 Sept 2025
15 Oct 2025
22 Sept 2025
14 Oct 2025
23 Sept 2025
22 Sept 2025 - 14 Oct 2025
Amount
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.: All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.: Electric resistance or induction butt welded tubes
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement : 6 fine sand)
Providing and fixing tripple wall Polycarbonate sheet, 10 mm thick, multi UV protected, of make LEXAN/MACROLON or equivalent, in roof upto any pitch, including fixing. The sheet shall be fixed using self drilling/self tepping screws with EPDM seal including Aluminium profiles and EDPM gaskets on joints. The cost of Aluminium profiles shall be paid separately. Aluminium tape on free ends of sheet to be applied to prevent ingress of moisture in sheet. All joints to be sealed with Silicon of approved quality.
Providing and fixing double wall Polycarbonate sheet, 8 mm thick, multi UV protected, of make LEXAN/MACROLON or equivalent, in roof upto any pitch, including fixing. The sheet shall be fixed using self drilling/self tepping screws with EPDM seal including Aluminium profiles and EDPM gaskets on joints. The cost of Aluminium profiles shall be paid separately. Aluminium tape on free ends of sheet to be applied to prevent ingress of moisture in sheet. All joints to be sealed with Silicon of approved quality.
P/f cellulose pad (Cell dex) 4" thick (imported) for cooling system
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.: Internal work - Exposed on wall:20 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.: Circular tank
Providing and fixing G.I. Sheet frame for cellulose pads in U shape using 16 guage G.I. Sheet complete in all respects including moulding to required size and shape
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing Aluminium profiles/moulding in required sections for roofing work. The wt. Of actual section fixed shall be taken for payment.
supplying & fixing single phase, 230 volts, 50 hz, self priming monoblock pump of rating 1.10 KW/ 1.5 HP, size 25 mmX25mm, duty SI, total head 50 mtr. (Make: Crompton/ Kriloskar)
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) a)18-22watt
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit with modular switch, modular plate, suitable GI/ PVC Box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make: Anchor/ Havells/ KEI/ Finolex). (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro: North West) i) Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed ISI medium class PVC conduit as required. (Wire Make: Anchor/ Havells/ KEI/ Finolex). i) 2x4 sqmm + 1x4 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed ISI medium class PVC conduit as required. (Wire Make: Anchor/ Havells/ KEI/ Finolex). i) 4x4 sqmm +2x4 sqmm earth wire
Supplying & fixing suitable size GI/ PVC box with modular plate and cover infront on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SPMCB, C curve including connection, painting etc. as required.(Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro: North West)
Providing & fixing following rating & breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connection, etc. as required. ( MCCB Make: Havells/ L&T/ C&S/ Standard).Note: MCCB supplied must be compatible to TPN DB) i) 100 Amp., 16 KA, TPMCCB
Supplying & fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB ,with provision of 100 amps TP 16 KA MCCB as incomer (but without MCB and incomer) as required.( TPN DB Make: Havells/ L&T/ C&S/ Standard). i) 8 way (4+ 24), Double Door
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) Single Pole
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) Tripple Pole
Supplying and fixing TP sheet steel enclosure on surface/recess along with 16/25/32 A ''C'' curve TP MCB complete with connections, testing commisioning etc. as required.
Earthing with GI Earth plate 600 mm x 600 mm x6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and laying 25mmx5mm G.I strip at 0.50 meter below ground as strip earth electrodes including connection of terminating with GI nut bolt,spring washers etc. as required(Jointing shall be done by overrlapping and with 2sets of GI nut bolts and spring washer spaced at 50mm)
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i)Above 35 sqmm. And upto 95Sq.mm
Laying and fixing of one no. PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall or surface as required. i) above 35 sqmm and upto 95 sqmm(clamped with 1mm thick saddle)
Supplying & making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3.5 x 50sqmm (45mm)
Supplying & laying of following size DWC HDPE Pipe (ISI marked) along with all accessories like socket, bend, coupler etc. confirming to IS 14930, Part 2 complete with fitting and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation & refiiling the trench but excluding sand cushioning and protective covering etc complete as required. i) 63 mm Dia (OD- 63 mm & ID-51 mm nominal).
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ KEI/ Havells/ Finolex) i) 3.5 core 50 sqmm
QUANTEK AGRO SCIENCE (BID ID -914508)
EARTH AGRO STRUCTURES PVT LTD (BID ID -906978)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .