| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹37.3 L+₹8.9 L (31.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | BHARDWAJ BUILDERS L2 | m/S Varun Gupta L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling of wall & ceiling boards (fiber, pulp, insulation etc) or insulation boards /slabs /blankets any thickness, including cover fillets complete all as specified and directed. | 550 | Sqm | 50 ₹27,500 | 20 ₹11,000 Lowest |
| 2.00 | S&F Fibrette Tile made of 'Wood fiber Cement Composite' 1mm width wood fiber 15mm thick size 595x595/595X1195 mm having excellent noise absorption of 1 NRC as per ISO: 354, Density 400 Kg/ m3 , meets Fire Ratings as per BS 476 Part 5, 6 and 7 class 1 and P, water resistant and thermal insulated. Installed on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results. as manufacturer's specification/instructions and including necessary scaffolding all as specified and directed. | 385 | Sqm | 4,600 ₹17,71,000 | 1,855 ₹7,14,175 Lowest |
| 3.00 | S&F for Hollow PVC Wall Lining consisting of 5mm thick wood grain ( as approved by GE/ Engr in Charge) printed PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing (or without PVC frame work), fixed in repair complete all as specified and directed by Engineer in Charge. | 165 | Sqm | 1,000 ₹1,65,000 | 855 ₹1,41,075 Lowest |
| 4.00 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification, complete all as specified and directed | 25 | RM | 50 ₹1,250 Lowest | 80 ₹2,000 |
| 5.00 | Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed. | 1.5 | Cum | 200 ₹300 Lowest | 255 ₹382.5 |
| 6.00 | M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:4, complete all as specified and directed. | 1.5 | Cum | 5,000 ₹7,500 Lowest | 5,890 ₹8,835 |
| 7.00 | S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including fixing fittings such as GI nipple for inlet, outlet, washout and overflow etc, including 20mm size ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed. | 4 | Each | 5,500 ₹22,000 | 4,500 ₹18,000 Lowest |
| 8.00 | S & F in repair CP Grating with or without hole fixed with cement. | 5 | Each | 100 ₹500 | 90 ₹450 Lowest |
| 9.00 | Taking down chowkats or frames but with shutters (with out taking off shutter from the frames) exc 1.5 sq.m but n. exc 4 sq.m each, complete all as specified and directed. | 2 | Each | 200 ₹400 Lowest | 255 ₹510 |
| 10.00 | S&F in repair Vitreous China Urinal, half stall type, white with spreader, waste pipe and necessary fittings complete all as specified and directed by Engineer-in-Charge. (Make : Jaquar/Kohler/ Cera)/Equivalant | 5 | Each | 6,000 ₹30,000 | 2,000 ₹10,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹87,000
Closing Date
22 Aug 2025, 6:00 pmClosed
Lt Col S N Gaikwad
Holta Cantt Palampur
SPL REPAIR TO BLDG NO P 9 AND PROVN OF DRAINAGE AT ENGR REGT LOC AT PALAMPUR MIL STN
2025_MES_722665_1
GEP-58/2025-26
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹87,000
1 Oct 2025
25 Jul 2025
29 Aug 2025
25 Jul 2025
22 Aug 2025
8 Aug 2025
Amount
Dismantling of wall & ceiling boards (fiber, pulp, insulation etc) or insulation boards /slabs /blankets any thickness, including cover fillets complete all as specified and directed.
S&F Fibrette Tile made of 'Wood fiber Cement Composite' 1mm width wood fiber 15mm thick size 595x595/595X1195 mm having excellent noise absorption of 1 NRC as per ISO: 354, Density 400 Kg/ m3 , meets Fire Ratings as per BS 476 Part 5, 6 and 7 class 1 and P, water resistant and thermal insulated. Installed on T24 grid system of 0.6mm thick Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per Fire Retardant IS 15061-2002 for excellent results. as manufacturer's specification/instructions and including necessary scaffolding all as specified and directed.
S&F for Hollow PVC Wall Lining consisting of 5mm thick wood grain ( as approved by GE/ Engr in Charge) printed PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing (or without PVC frame work), fixed in repair complete all as specified and directed by Engineer in Charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification, complete all as specified and directed
Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:4, complete all as specified and directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including fixing fittings such as GI nipple for inlet, outlet, washout and overflow etc, including 20mm size ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed.
S & F in repair CP Grating with or without hole fixed with cement.
Taking down chowkats or frames but with shutters (with out taking off shutter from the frames) exc 1.5 sq.m but n. exc 4 sq.m each, complete all as specified and directed.
S&F in repair Vitreous China Urinal, half stall type, white with spreader, waste pipe and necessary fittings complete all as specified and directed by Engineer-in-Charge. (Make : Jaquar/Kohler/ Cera)/Equivalant
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed.
M&L rendering 15mm thick plaster in CM 1:6 on brick or concrete surface or other than fair faces of brick masonry, finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick plaster in CM 1:4 on brick masonry or concrete surfaces or other than fair faces of brick masonry, finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L Distempering with 1st quality acrylic distemper (ready mixed ) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete as per manufacturers specification two or more coats over 2mm wall care putty on new surface of wall including preparation of surfaces with complete all as specified and directed by Engineer-in-Charge.
M&L Distempering with 1st quality acrylic distemper (ready mixed ) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete as per manufacturers specification two or more coats over 2mm wall care putty on old surface of wall including preparation of surfaces with complete all as specified and directed by Engineer-in-Charge.
Material & Labour for appplying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces of wall complete including preparation of surfaces of walls complete all as specified and directed by Engineer-in-Charge.
Material & Labour for appplying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over old surfaces of wall complete including preparation of surfaces of walls complete all as specified and directed by Engineer-in-Charge.
Demolition of floor, hearth or wall tiling including cement mortar bedding or backing coat, removing rubbish off the premises, removal and depositing where directed and leaving the work clear of any plastering complete all as specified and directed .
M&L vitrified Ceramic tiles 10mm thick (square / rectangular) light shade polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15 mm thick screed bed or bedding layer in CM 1:4 complete all as specified by Engineer in Charge.
M&L Vitrified Ceramic tiles 10mm thick (square / rectangular) light shade polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 10 mm thick backing coat in CM 1:4 complete all as specified by Engineer in Charge.
M&L Glazed ceramic any shade tiles in vertical surfaace 350mm x 250mm x 7mm/450mm x 350mm x 7mm/450x300x7mm/ 600x300x 7mm thick set and jointed in neat cement slurry, pointed in white or coloured cement to match the colour of tiles, over and including 10mm thick backing coat in CM 1:4 to receive tiles, Incl dismantling complete all as specified and directed by Engineer in Charge.
Demolition of existing cement concrete padding of water proofing treatment from roof including taking down bituminous polythine sheets plasters etc over all thickness n.exc. 200 mm cleaning of concrete surface by wire brush scrubbing down with water and removing the dust debris etc to a distance exceeding 1.50 Km but n.exc. 5.00 Km from the work site concrete complete all as specified and directed by Engineer-in-Charge.
15 mm thick (average) screed bed/ plaster in cement mortar 1:4 in order to maintain proper slope and base over existing roof surface for laying of APP based polymeric membrane, mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified & directed by Engineer in Charge.. (Note:- WPC and polymeric membrane shall be measured and paid separately)
Applying a coat of bitumen primer conforming to IS: 3384-1986 over plastered surfaces @ 0.40 litres/ Sqm of density 0.87-0.89kg/ litres at 25° C and viscosity 70-160CPS (Bitumen primer shall be of same make as of memebrane) including preparation of surfaces, complete all as specified & directed by Engineer in Charge.
APP (Atactic Poly-propylene polymer) modified membranes, five layered, 3mm thick weighing not less than 3.6 kg/ Sqm, having a centre core of polyester non-woven mat (FP) reinforcement dipped into APP modified mix and sealing all the over laps 75mm on length side and 100mm on width side of membranes by torching as per manufacture's instructions by authorised applicator only after applying evenly a coat of bitumen VG-10 grade @ 1.20 kg per sqm on the bottom of APP and on top of joints of APP , complete all as specified & directed by Engineer in Charge.
Supply only liquid water proofing compound complete all as specified.
Excavation in trenches,nexc 1.50m wide and n exc 1.50m in depth for foundation,etc or for shafts,wells,cesspits,manholes,pier holes,etc n exc 10 sq m on plan and getting out any type of soil complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundations,filling and mass concrete complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:6, complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed.
M&L rendering 15mm thick plaster in CM 1:4 on fair faces of brick/concrete surfaces finished the surface even and smooth without using extra cement mixed with WPC @ 3% by Wt. of cement (external surfaces) WPC shall be measured and paid separately complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L pre-cast cement concrete type B-1 1:2:4 (20mm graded crushed stone aggregate) as in landings, cover slabs for man holes,chullah hoods,chajjas,water troughs,mangers,shelves and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc25 cm any type of soil complete all as specified and directed.
Removing excavated soil n exc.50m and depositing where directed at aleveln exc 1.50m above the sterting point complete all as specified and directed.
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated FRLS and unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid Concealed conduit not less than 1.8 mm thick (ISI marked) with all accessories including bends, cross, elbows tees etc of suitable size including concealed MS pressed steel (Modular sunken box) terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and Modular cover plate as top cover (ISI marked) including 1.5 sqmm PVC FRLS insulated unsheathed copper conductor multi stranded cable for continuous earth conductor connected to common arth dolly , complete all as specifid and directed for the following :- Note- (a) Proper colour coding is to be followed as per IS specification. (b) Point wiring considered for Modular switches and sockets, rate of metallic sunken box and modular sheet cover plate and other connected accessories (of any size 1 to 12 way as per site requirement) required for modular point wiring included in quoted rate. (c) Rate of modular switch and sockets will be paid seperately under relevant item.
Description all as per serial item No 39 here-in-before but one 5 pin socket outlet, 5 amps on the same board complete all as specified and directed.
Description all as per serial item No 39 here-in-before but one 5 pin socket outlet, 5 amps, independent complete all as specified and directed.
Description all as per serial item No 39 here-in-before but for one 5 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed.Note:-Power circuit shall be done in separate circuit .
S&F in replacement ceiling rose, 3 terminal surface type complete all as specified and directed.
S&F in replacement angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in replacement Modular switch 1 way 6 A,1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement Modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement Socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in repair Socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB's should be same make.
S&F in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S &F of SPN 40 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S &F of SPN 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S & F of 415V 10KA 'C' curve TPN 63 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S & F 415V 10KA 'C' curve TPN 100 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
M&L for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sq mm for phase and neutral and one run of 2.5 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth alongwith PVC conduit will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding. Note: Cutting chases on the wall whereever required is deemed to be included in unit rate quoted.
All as per item No 55 above but 6 Sqmm all as specified and directed
Supply and fixing LED spike light type 9 watt 230 volts AC outdoor type for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete
Supply and fixing Recess mounted slimLED luminaires with drop down diffuser light of size 2ft x2ft ,36 watt ,230 volts Ac corrosion resistant complete all as specified and directed.
S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S&F LED Bulb 09/10 watt with provision of fixed in Lamp holder complete all as specified and directed.
S&F LED 'T' Type Mirror light fitting 09/10 watt with provision of fixed in Lamp holder complete all as specified and directed.
Supply and fixing in replacement of MCCB 250 Amp rating,4-pole 415V, 50 Hz breaking capacity 36 KA, Adjustable & fixed magnetic setting type. all as specified
Supply and fixing in replacement of MCCB 63Amp rating,4-pole 415V, breaking capacity 16KA. all as specified
M&L for detached of solar roof top power plant from roof and shift at safe site for reinstallation after completion of roof work with all conneted accessories and fittings complete all as specified
Supply, fixing & testing 70W LED flood light fitting IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed including taking down.
S&F stainless steel round pipe of dia 50 mm for hanging lights with all connected fitting item complete all as specified and directed by Engr in charge as required at site
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incommer 125Amp 4 pole and including MCCB 100 Amps 4 pole 16KA (where MCB are to used) complete with suitable size of bus bar complete fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces tomatch with existing specification including taking down old DBcomplete all as directed by Engr in charge
S&F Exhaust fan 250 mm sweep plastic body complete with all fittings all as specified
Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth wire strip of size 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost all as directed by Engr-in-Charge. (Note: GI strip & GI pipe beyond 7.5Mtr length from earth electrode shall be measured and paid separately).
BHARDWAJ BUILDERS (BID ID -3394708)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .