Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 CrAccepted-AOC | ₹4.7 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹4.9 Cr+₹20.4 L (4.31%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹4.9 Cr+₹20.4 L (4.31%) | L2 | Rejected-Finance Being other than lowest bidder |
| 3 | L3₹5.0 Cr+₹21.2 L (4.47%)Rejected-Finance | ₹5.0 Cr+₹21.2 L (4.47%) | L3 | Rejected-Finance Being other than lowest bidder |
| 4 | L4₹5.0 Cr+₹29.9 L (6.31%)Rejected-Finance A 31 RAJENDRA NAGAR BAREILLY UP 243122 | BAREILLY | BAREILLY | UP | 243122 | ₹5.0 Cr+₹29.9 L (6.31%) | L4 | Rejected-Finance Being other than lowest bidder |
| 5 | L5₹5.1 Cr+₹31.3 L (6.61%)Rejected-Finance 160 PREM NAGAR BAREILLY | ₹5.1 Cr+₹31.3 L (6.61%) | L5 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹4.5 Cr
EMD Value
₹5.3 L
Closing Date
20 May 2023, 6:00 pmClosed
CHIEF ENGINEER BAREILLY ZONE
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
CONSTRUCTION OF OFFICE AND RESIDENTIAL ACCOMODATION OF DEFENCE ESTATE OFFICE OF BAREILLY CIRCLE
2023_MES_579229_1
CEZB/BLY/T-28 OF 2022-23
Open Tender
Civil Works
Lump-sum
365 days
BAREILLY
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE Project Bareilly
₹5.3 L
Yes
27 Jun 2023
6 Feb 2023
29 May 2023
6 Feb 2023
20 May 2023
3 May 2023
7 Feb 2023 - 15 Feb 2023
Amount
Total amount of Sch 'A' Part I (Building Work) (For details see Sch 'A' Part-I A in PDF folder)
Total amount of Sch 'A' Part II A (Internal Water Supply) (For details see Sch 'A' Part-II A in PDF folder)
SCHEDULE 'A' PART-II B (INTER WATER SUPPLY)
S&F for brass chromium plated, angle valve, fancy type, 15 mm dia complete all as specified and directed.
S&F bib cock with wall flange quarter turn (low-flow) 16mm dia complete all as specified and directed.
S&F brass CP Mixer for mixing Hot & Cold water screwed down for iron pipe 15mm bore complete all as specified and directed.
S&F for 15mm bore pillar tap, cast copper alloy, with capstain head, chromium plated,screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, fancy type, screwed for 20mm bore CPVC pipe of for brass ferrule or to CPVC socket / reducing socket having maximum flow rate of water 6 litre per minute @ 45 PSI or 3.1 bar pressure complete all as specified and directed.
S&F two way bib cock with wall flange quarter turn (low-flow) 16mm dia complete all as specified and directed.
S&F hand shower (health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (back flow preventer) complete all as specified and directed.
S&F CP brass connection 600mm long with brass checknut suitable for 15mm bore complete all as specified.
S&F 15mm bore Bib tab, cast copper alloy, fancy type, chromium plated with cruth or butterfly handle screw down, screwed for 20mm bore CPVC pipe of for brass ferrule or to CPVC socket / reducing socket having maximum flow rate of water 6 litre per minute @ 45 PSI or 3.1 bar pressure complete all as specified and directed.
Total amount of Sch 'A' Part III -A (INTERNAL ELECTRIFICATION) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART III-B (INTERNAL ELECTRIFICATION)
M & L point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed of the following. Note : 1. Point wiring should be carried out on surface mounted rigid PVC conduit or casing-caping on existing RCC beam, column, roof or false ceiling. 2. Colour code will be maintained as per IE rule i.e. Red/Yellow/Blue for phases, Black for Neutral and Green for earth wire. 3. Modular Metal flush box, modular plate and frame, Switch, socket, regulator, bell push will be measured and paid under respective item. Contd.....
(a) One light point /bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through regulator
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
(e) one light point controlled by two way point wiring with two no of two way switch with cables 1.5 sqmm size in PVC conduit
All as per item No 7 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm complete all as specified and directed.
Supply and fixing modular metal flush box 8 module ISI marked complete all as specified and directed
S & F lamp holder, PVC / Polycarbonate type with cold grip cap suitable for batten fitting including with 9 watt LED lamp complete all as specified and directed.
S & F new sheet metal enclosure DB TPN, 415 volt with 200 amps rated copper bus bar for double door 8 way IP-43 DBs IK-09 suitable for one MCCB as incoming and MCB TPN as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
S & F new sheet metal enclosure DB TPN, 240 volt with 200 amps rated copper bus bar for double door 4 way IP-43 DBs IK-09 suitable for one MCB TPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
S & F new sheet metal enclosure DB SPN, 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43 DBs IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
S & F new sheet metal enclosure DB SPN, 240 volt with 200 amps rated copper bus bar for double door 4 way IP-43 DBs IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. (MCBs shall be measures and paid seperately)
M & L sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 2.5 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 4 Sqmm cable and one run of 2.5 Sqmm cable and one run of 20mm dia PVC Conduit shall be measured and paid as one unit.
M & L sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 6.0 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 4.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 6 Sqmm cable and one run of 4.0 Sqmm cable and one run of 20mm dia PVC Conduit shall be measured and paid as one unit.
S & F ceiling fans, complete with blades, down rods, electronic fan regulator and accessories 230V, 1200 mm sweep, min air delivery 245 CFM BLDC type along with five star rated complete all as specified and directed.
S & F modular blanking plate on existing modular plate & switch complete all as specified and directed.
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and including galvanized iron earth strip, 25 x 4 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanised steel protection pipe light grade 40mm dia and GI pipe light grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion. Note : The unit rate includes for 40mm light grade protecton pipe and GI earth strip 25 x 4 mm from top of earth plate upto 7.50 metre above ground level. The earth pit shall be constructed atleast 1.5m away from the top of earth electrode complete all as specified and directed.
Supply, installation, testing and commissioning of water heater storage type, electric suitable for single phase, 50Hz, AC supply, stainless steel inner assembly, 2KW heating element, twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1m of three core 2.5 sqmm twisted copper conductor cable PVC sheathed, three pin plug top, polythelene pipe connection piece 450mm long of 6 Kg per Sqcm with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopter at ends, at hot water outlet, with safety fusible plug confirming to relevant IS of 25 litres capacity complete all as specified and directed.
Total amount of Sch 'A' Part IV (Earth work and site clearance) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part V A (Road, Path, Culvert & Hardstinding) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' Part V B (Road, Path, Culvert & Hardstinding)
M & L for Providing precast cement concrete type B1 1:2:4 20mm graded stone aggregate in kerb stone of size 300 x 150 x 300 (LXWXD), window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham?fers, weatherings, throat- ing etc. and se in cement mortar 1:6 complete with joints to match complete all as specified and directed.
M&L for 20mm graded stone aggregate as in base, 75mm compacted thickness with hand held compactor machine complete all as specified and directed.
M&L for 12.5mm graded stone aggregate, 75mm compacted thickness with hand held compactor machine complete all as specified and directed.
M & L for Providing and laying factory made chambered edge Cement Concrete grass paver blocks having 50% or more opening in drive ways or parking etc, The grass paver block shall be of M-40/M50, 60 mm thick reflective (minimum 75% SRI value) & inter locking type factory made. The paver block shall be brought from the manufacturer mentioned hereinafter and as approved by the GE. The compressive strength of paver block shall be 400kg/sqcm and of colour as approved by the GE. The top layer of paver blocks shall not be less than 6 to 8mm thick and should have Anti skid groove finish (vermicular finish). Paver block should have 1mm spacer to provide minimum gap between paver unit to allow joint filling send to go in it and establish complete interlocking between blocks. Joints shall be filled with sand as directed by the Engineer-in-Charge. The sand shall be free from clay and alkaline particles and conform to relevant IS. The edges of the paver block shall be neatly trimmed to fit within kerbs along the peri-pheri of the paved area. The unit rates quoted shall be inclusive of laying of paver block of different colour for making the Anchor pattern of size 4x6m and other pattern as directed by the GE/Engineer-in-Charge.
M & L for Non woven Geotextile nominal weight 210GMS - polypropylene, Colour - GREY Roll Size - 1M x 400 M (L) - 1 Roll i.e. 400 Sqm complete all as specified and directed.
Total amount of Sch 'A' Part VI 'A' (Sewage Disposal) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VI-B (Sewage Disposal)
M&L 150mm bore, HDPE DWC drain pipes (grade SN 8) laid in trenches and jointed with necessary fitings complete all as specified and directed.
Total amount of Sch 'A' Part VII (Area Drainage) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part VIII A (Compound Wall & Gate) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VIII-B (Compound Wall & Gate)
M&L steel gate 6m wide and 2.10m high, excavation and earth work in soft/loose soil, RCC piller, PCC coping bed block/ bed plate, wheel track, rendering 10mm thick in cement mortar 1:4 & two coat cement based paint over one coat of primer and two coat of synthetic enamel paint over one coat of red oxide primer on the surface of gate complete all as specified and directed. (Reference TD No. BZ/Bly/203 Sheet No. 17 R/21)
Total amount of Sch 'A' Part IX A (External Water Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART IX-B (External Water Supply)
Cutting to existing CI/DI pipe line in position 150 mm dia for insertion of and including tee 150x 100x 100mm, branch, collar including jointing material etc. complete all as specified and directed.
Supply, Install and testing sluice valve 100 mm dia cast iron double flanged with drilled stainless steel spindle and CI wheel head IS-14846 sluice valve class PN-1.6 with and incl. Drilled flanges fibre sheet packing MS nuts, bolts & washers of reqd size complete all as specified and directed.
Supply, Install and testing sluice valve 80 mm dia cast iron double flanged with drilled stainless steel spindle and CI wheel head IS-14846 sluice valve class PN-1 with and incl. Drilled flanges fibre sheet packing MS nuts, bolts & washers of reqd size complete all as specified and directed.
M&L for construction of brick masonry valve pit (950 x 950 x 950) mm (outer dimension) with sub class 'B' bricks old size built in CM 1:4, PCC 1:2:4 type B-1 as in foundation concrete, bed/ floors, coping and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below GL and mixed with water proofing compound @ 2% by weight of cement with and including 40 X 40 X 6 mm angle iron frame 3.15 mm thick MS sheet cover with locking arrangements and one No. 50 mm size 4 lever MS lock with key in duplicate including excavation and earthwork in soft/loose soil, painting steel surface with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed.
Total amount of Sch 'A' Part X A (External Electric Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART X-B (External Electric Supply)
Supply, installation, Testing and Commissioning of 11 kV, 630 A, 21 KA, for 3 Sec, SF6 insulated Ring Main Unit (RMU) consist of motorized 3 load break switch and VCB with suitable site repalceable bushings complete in all respects as per specs ( CCCV) : STANDARD: IEC 62 271-200 C RMU TYPE: 11kV,630A,21KA/3SEC, SafeLink CB ,CVC OUTDOOR MANUAL RMU RATED VOLTAGE: 11 KV RATED BUSBAR CURRENT :630A RATED FREQUENCY:50Hz POWER FREQUENCY WITHSTAND VOLTAGE / BIL:38KV / 95KVp D RATED SHORT CIRCUIT CURRENT:21KA D (Contd....)
RATED SHORT CIRCUIT CURRENT DURATION: 3s DEGREE OF PROTECTION-TANK: IP67 DEGREE OF PROTECTION-SWITCHGEAR : IP54 BUS BAR MATERIAL: CU AMBIENT TEMPERATURE: -25. 40Deg C RMU FRONT COVER PAINT SHADE: RAL 7035 E RMU ENCLOSURE PAINT SHADE:DA GREY 632 OF IS5 ALTITUDE: <1500m BUSBAR INSULATING GAS:SF6 NOMINAL OPERATING GAS PRESSURE ;1.2 BAR @20 Deg C GAS LEAKAGE/ANNUM: 0.1%
Supply, instalation , testing and commissioning transformer, copper wound stepdown outdoor type complete with standard fittings HT 11 KV 3 phase, LT 433 volts,3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS-1180 (Part-I) of capacity 100 KVA copper wound including intial oil filling to appropriate level with desired dielectric strength and connected with the electric system including jointing materials,temperature rise 50/55 degree C and standard accessories as under :- (a) Cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side . (b) Arrangement for connecting busbar trunking with neutral brought out as earthing terminal . (c) Off load changer +/- 7.5% @ 2.5% (d) Bi-directional roller. (e) conservator with drain valve (Contd....)
(f) earthing terminals 02 Nos of the body of transformer . (g) Double diaphragm explosion vent. (h) Radiator with top & bottom shut off valve . (j) first filling of oil including make up fill. (k) Silica gel breather with oil seal . (l) Rating and diagram plate . (m) Air release plug. (n) Winding temprature indicator.(WTI) (o) Oil temperture indicator. (p) Magnetic oil level gauge. (q) Marshalling Box
Supply and fix junction box made up of SMC of size 300 x 250 mm with front side openning complete including 4 Nos bus bar of appropriate size and one No MCB SP 6 Amp, to be fixed on poles with 2 Nos clamp 25 / 6 mm flat iron complete all as specified and directed.
Supply, install, testing and commissioning Main LT panel, outdoor type cubical panel board, made out of 3.15 mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 52 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators comprising of the following:- INCOMER i) MCCB 4 pole 160A, incomer, 415V, 50Hz, 25 KA - 01 No. OUTGOING i) MCCB 4 Pole 100 A, 415V, 16KA - 01 No. ii) MCCB 4P 63 Amp , 16 kA - 2 Nos. ii) MCB SPN 20A, 10 kA - 2 No. BUSBAR 200 A rated aluminium bus bar with colour coded heat shrinkable sleeve (Contd....)
Supply fabrication installation testing & commissioning (CPRI approved) 440V AC APFC, Panel compartmentalized & modular type outdoor type in 3.15 mm CRCA sheet of appropriate size front operate able single door front & back operate only. Dust & vermin proof. Cable entry through 2cm CRCA gland plates –Top & bottom only. Powder coat- ed after & tank pre-treatment process segments grey space on body/doors & orange shade on mounting gland plates + Incomer Doors. 3 phase HS sleeved coat coded aluminium Main busbar of 700A (70 x 10mm for 3 phase) with transparent polycarbonate covers & on SMB/DMC insulators. 25 x 6mm Aluminum Earth Busbar running across the whole length of the LT panel with studs at both the side –ends. Lifting arrangement /Hooks at the top wiring with appropriate size of copper Industrial Cables Black Paints Base Frame -40x40x50 mm angle frame. Cables glades brass chromium plated of different sizes suitable for incoming & outgoing MCCB's are fitted with following specified items. (Contd....)
(A) Rating -50KVAR With 2 Steps (2X25) APFC Panel Incoming MCCB Microprocessor based release with overload & short –circuit protections Rating 160A FP 25 KA (lcs = 100 Icu Contacts 7 Rotary Handle mechanics -01 Nos (Schneider /ABB/C&S Make)
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in a pit (earth pit of depth not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoal and common salt 15cm thick each layer and electrode connected to and including galvanized iron earth strip, 32 x 6 mm (earth lead) by means of bolts, nuts, check nuts and washers of galvanised steel protection pipe light grade 40mm dia and GI pipe light grade 20mm dia bore for watering, funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sq m) and frame including all excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and as directed including testing on completion. Note : (i) The unit rate includes for 40mm light grade protecton pipe and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level. The earth pit shall be constructed atleast 1.5m away from the top of earth electrode complete all as specified and directed.
Supply, transporting, erecting and fixing steel tubler, swaged welded pole of over all height of 11.00 Mtrs complete type 410 SP 55 with cast iron base plate, pole cap/finial taper plug bolts, nuts washer, including painting with two coats of aluminium paint one coat over a red oxide primer and 03 Nos band/straps with fluorescent red post office box-colour (30 cm wide each) synthetic paint at a distance of 30 cm from plinth block and numbering of poles including painting one coat on steel surface of bituminous paint embeded in concrete, complete all as specified and directed.
Cutting into existing road of bitiminous macadam / concrete road to the required width / depth of LT cables for passing GI pipes/cables and making good to match with existing surfaces complete all as specified and directed.
SCHEDULE 'A' PART XI (Air Conditioning, Geyser and Desert Cooler)
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity 2 TR incl stand for outdoor unit, floor/wall mounted, copper tubing and necessary drain pipe complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR incl stand for outdoor unit, floor/wall mounted, copper tubing and necessary drain pipe complete all as specified and directed.
Supply and fixing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 litres complete all as specified and directed.
Supply and fixing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 120 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 1 KVA complete all as specified and directed.
Supply, install, testing and commissioning of storage type water heater of capacity 25 litres, BEE 5 star rated with shock resistant water proof ABS outer body , IP4X water proof technology, glass lined enamel coated heating element, temperature indicator, tank designed to withstand 8 bar pressure, fire retardant cable complete alongwith necessary connections inlcuding PVC piping, fittings etc. complete all as specified and directed. Make : Bajaj Calenta 25 L
Supply and installation of Desert Coolers ISI marked made out of 1.0 mm thick PGI sheet, blade size 406/16 mm PVC body, electrical driven single phase speed motor 1400 RPM, 160 watt copper wounded,air flow capacity 4000 Cum/Hr, alongwith tank capacity 100 ltrs manually oparated louvers movement , top water inlet complete with pump and motor complete all as specified and directed.
Total amount of Sch 'A' Part XII (Demolition) (For details see Sch 'A' in PDF folder)
Note : Tenderers may note that amount of credit Rs 39,519.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
yash enterprises
VEE SONS BUILDERS PVT LTD
M/s J P Bhatia
Builders Harpal
Sudhir Sharma Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .