Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LQualified Make: APCOM
Model: APCOM , BC-1ST 12V 12A 109 SHIVA MARKET PITAMPURA DELHI NORTH WEST DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Make: APCOM
Model: APCOM , BC-1ST 12V 12A | L1 | Qualified | |
| 2 | L2₹1.4 L+₹20,700 (16.7%)Qualified Make: RAJ ENGINEERS
Model: RAJ , RE BC-1ST 12V 12AMP 493 1 ROORKEE RAJ ENGINEERS SOT STREET VILLAGE TOWN ROORKEE CITY ROORKEE HARIDWAR UTTARAKHAND 247667 INDIA | HARIDWAR | UTTARAKHAND | 247667 | Make: RAJ ENGINEERS
Model: RAJ , RE BC-1ST 12V 12AMP | L2 | Qualified | |
| 3 | L3₹1.5 L+₹25,300 (20.4%)Qualified Make: MULTI TECHNO SERVICES
Model: Multi Techno Services 1212-S1A 210 PHASE IV UDYOG VIHAR GURGAON HARYANA 122015 | GURUGRAM | HARYANA | 122015 | Make: MULTI TECHNO SERVICES
Model: Multi Techno Services 1212-S1A | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Jun 2018, 8:00 pmClosed
battery chargers Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 1 Year (s) Battery Chargers ( 23 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology SMPS Based SMPS Based Compatibility with battery type (User Selectable) Lead acid & Tubular &VRLA- SMF Tubular
Lead acid
VRLA- SMF
Tubular & VRLA-SMF
Lead acid & VRLA- SMF
Tubular & Lead acid
Lead acid & Tubular &VRLA-SMF Number of Independent charging stations (in numbers) 1 1 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush current Yes - 1/4 Facility for charging deep discharged battery through pulse charging. yes - Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes - Digital display of output voltage and current Yes - LED Indication for Charging Status
Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the - 2/4 voltage is reduced from 280 volt Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt - Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt - Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. ETDC (MH) T&M – 077 - Test report date 29.09.2014 - Name of Lab STQC-ETDC (Govt. of India Lab) - Address of Lab B-108
PHASE VIII
Industrial Area
S.A.S. Nagar
Mohali (Punjab) - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 DINESH SINGH 799205
TELIAMURA
AMARPUR ROAD
SHQ BSF TELIAMURA
KHASIAMANGAL
PO- TELIAMURA
23 30 EMD Required No ePBG Required No
171508
GEM/2018/B/24443
battery chargers
30 days
Tripura; Khowai
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| battery chargers Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 1 Year (s) Battery Chargers ( 23 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology SMPS Based SMPS Based Compatibility with battery type (User Selectable) Lead acid & Tubular &VRLA- SMF Tubular | - | - | - |
| Lead acid | - | - | - |
| VRLA- SMF | - | - | - |
| Tubular & VRLA-SMF | - | - | - |
| Lead acid & VRLA- SMF | - | - | - |
| Tubular & Lead acid | - | - | - |
| Lead acid & Tubular &VRLA-SMF Number of Independent charging stations (in numbers) 1 1 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush current Yes - 1/4 Facility for charging deep discharged battery through pulse charging. yes - Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes - Digital display of output voltage and current Yes - LED Indication for Charging Status | - | - | - |
| Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the - 2/4 voltage is reduced from 280 volt Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt - Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt - Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. ETDC (MH) T&M – 077 - Test report date 29.09.2014 - Name of Lab STQC-ETDC (Govt. of India Lab) - Address of Lab B-108 | - | - | - |
| PHASE VIII | - | - | - |
| Industrial Area | - | - | - |
| S.A.S. Nagar | - | - | - |
| Mohali (Punjab) - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 DINESH SINGH 799205 | - | - | - |
| TELIAMURA | - | - | - |
| AMARPUR ROAD | - | - | - |
| SHQ BSF TELIAMURA | - | - | - |
| KHASIAMANGAL | - | - | - |
| PO- TELIAMURA | - | - | - |
| 23 30 EMD Required No ePBG Required No | - | - | - |
Exempted
7 Jun 2018
4 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_171508.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .