Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Due to Technical reasons |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Due to technical reasons |
Tender Value
₹8.0 L
EMD Value
₹16,040
Closing Date
6 Oct 2023, 2:00 pmClosed
Executive Engineer ED Baramulla
Executive Engineer ED Baramulla
Improvement and stablization of HT /LT network at various site of ward no. 1 and 7 Mohura by way of replacement damaged poles and conductor under PRI Grants 2023-24
2023_PDD_230204_1
EDB/89
Open Tender
Electrical Works
Turn-key
45 days
Improvement and stablization of HT /LT network at
Please refer Tender documents.
4 documents required · 4 mandatory
₹520
Yes
Executive Engineer ED Baramulla
₹16,040
Yes
18 Oct 2023
18 Sept 2023
7 Oct 2023
18 Sept 2023
6 Oct 2023
19 Sept 2023
18 Sept 2023 - 19 Sept 2023
Amount
Supply,Carraige upto site, Erection, testing and commissioning of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long )
Supply, Carriage up to site, Erection, testing and commissioning of Steel Tubular Pole, 8 Mtr. Long Pole(SP15) with planting depth of 1/6 the of the height of the pole, (8 mtr. Long )
Supply, Carriage up to site, laying ,stringing, tensioning , binding of ACSR Conductor, (50mm2 ACSR Conductor)
Supply,Carraige upto site, Installation, testing and Commissioning of G.I Channel V-X arms 75x40x6mm with Top bracket including suitable clamps/collars (06Nos.) As per REC Standard
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV Polymeric composite pin insulators 12kV, 5kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm
Supply,Carraige upto site, Installation, testing and Commissioning of Galvanised Nuts & Bolts
Supply,Carraige upto site, Installation, testing and Commissioning of Galvanised stay set with 50X8mm stay clamp, guy insulator (02nos), anchor plate (200X200X6)mm nut bolts, 02nos turn buckle, 1.8m long, 16mm diameter solid GS stay rod & 7/3, 15mm dia GI stranded wire complete
Supply,Carraige upto site, Installation, testing and Commissioning of G.I LT structure mukhi type with shackles
Supply,Carraige upto site, Installation, testing and Commissioning of Cement bottoming 1:2:4 as per standards 0.5cum / pole
Supply,Carraige upto site, Installation, testing and Commissioning of Cement bottoming 1:2:4 as per standards 0.5cum / pole
Earthing complete by GI pipe 40mm 3mtr long through GI strip 25X3mm
Supply,Carraige upto site, Installation, testing and Commissioning of Painting of poles (red oxide=2ltr & Alminium paint=2ltr )
Supply,Carraige upto site, Installation, testing and Commissioning of Danger Plate with clamps
Supply,Carraige upto site, Installation, testing and Commissioning of Anti climbing device with clamps
Supply, Carriage up to site, Installation, of Sign Board (2X2 feet) along with required accessories like clamps, nuts and bolts etc.
M/s KHAN ELECTRICAL WORKS & SUPPLIERS
MIR SONS ELECTRICALS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .