| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC MANDI PILIBANGA HANUMANGARH RAJ | HANUMANGARH | RAJASTHAN | 335063 | ₹23.5 L Quoted ₹24.0 L | L1 | Accepted-AOC L-1 Bidder |
| 2 | L2₹27.4 LRejected-Finance 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹27.4 L | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹30.6 LRejected-Finance | ₹30.6 L | L3 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | SARASWATI ELECTRIC STORE L1 | RUHI ASSOCIATES L3 | PANWAR ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Labour Only for attending Complaints of any type of fault of central Ac plant, package type AC plant, casette Type ac, chiller unit, Duct Acs, AHU, cooling tower and any type of fault in condenser/cooling tower motors of any HP and its allied electrical repairs at different locations under GE(A) no.1 Jodhpur carrying out necessary repairs at site by replacing unservicable spares unscrewing from position, complete all as specified and directed and specified . NOTE :necessary spare parts reqyired to required at site shall be measured and paid seprately under relevant items .contractor shall arrange necessary transportation to bring the taken down parts for repair/ replacement | 200 | Each | 500 ₹1 L | 500 ₹1 L | 1,000 ₹2 L |
| 2.00 | Material and Labour for repairing /servicing / cleaning /testing complete of 120 TR capacity chiller unit of Voltas make complete with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge
Note :- Servicing work of chiller unit to be done by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction.Testing shall be done for leak test, vaccum test, insulation, HV, wiring and performance test with complete . All spares parts as required for repair /servicing shall be measured and paid separately under relevant item 2 of Sch 'A'. | 2 | Each Job | 20,000 ₹40,000 | 12,000 ₹24,000 | 25,000 ₹50,000 |
| 3.00 | Material only for replacement of following parts/items suitable for 120TR capacity chiller unit of Voltas Make :-
(i) Compressor oil CPI-120 | 80 | Ltrs | 700 ₹56,000 | 1,650 ₹1.3 L | 2,000 ₹1.6 L |
| 3.01 | (ii) Temperature sensor as suit to existing. Model No. MCST100 | 4 | Nos | 5,000 ₹20,000 | 2,500 ₹10,000 | 3,000 ₹12,000 |
| 3.02 | (iii) Gas sensor as suit to existing. Model No. MCST100 | 4 | Nos | 1,500 ₹6,000 | 2,500 ₹10,000 | 3,000 ₹12,000 |
| 3.03 | (iv) Eliminator for oil filteration as suit to existing | 4 | Nos | 4,500 ₹18,000 | 4,000 ₹16,000 | 3,000 ₹12,000 |
| 3.04 | (v) Dryer make: denfoss of size 3/8" | 2 | Each | 2,000 ₹4,000 | 1,500 ₹3,000 | 2,000 ₹4,000 |
| 3.05 | (vi) Solenoid switch as suit to existing. | 2 | Each | 2,000 ₹4,000 | 2,000 ₹4,000 | 3,000 ₹6,000 |
| 3.06 | (vii) LP/HP cut out switch suitable for existing AC plant cap 120TR. | 1 | Each | 2,500 ₹2,500 | 3,500 ₹3,500 | 7,000 ₹7,000 |
| 3.07 | (viii) Pressure gauge (0-150 psi) analog type with stainless steel syphon suitable for HVAC plant of capacity 120 TR as existing. | 4 | Each | 1,000 ₹4,000 | 650 ₹2,600 | 1,000 ₹4,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
2 Dec 2025, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
REPAIR/ MAINTENANCE OF CENTRAL AC PLANT AND 3 PHASE AC AT CERTAIN LOCATIONS IN ARMY AREA JODHPUR UNDER GE (ARMY) No 1 JODHPUR
2025_MES_738426_1
GE/JODH (A) No 1 OF 2025-26 (9371/E8)
Open Tender
Civil Works
330 days
Jodhpur
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (A) No 1
₹70,000
Yes
5 Jan 2026
4 Nov 2025
9 Dec 2025
4 Nov 2025
2 Dec 2025
18 Nov 2025
Amount
Labour Only for attending Complaints of any type of fault of central Ac plant, package type AC plant, casette Type ac, chiller unit, Duct Acs, AHU, cooling tower and any type of fault in condenser/cooling tower motors of any HP and its allied electrical repairs at different locations under GE(A) no.1 Jodhpur carrying out necessary repairs at site by replacing unservicable spares unscrewing from position, complete all as specified and directed and specified . NOTE :necessary spare parts reqyired to required at site shall be measured and paid seprately under relevant items .contractor shall arrange necessary transportation to bring the taken down parts for repair/ replacement
Material and Labour for repairing /servicing / cleaning /testing complete of 120 TR capacity chiller unit of Voltas make complete with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge Note :- Servicing work of chiller unit to be done by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction.Testing shall be done for leak test, vaccum test, insulation, HV, wiring and performance test with complete . All spares parts as required for repair /servicing shall be measured and paid separately under relevant item 2 of Sch 'A'.
Material only for replacement of following parts/items suitable for 120TR capacity chiller unit of Voltas Make :- (i) Compressor oil CPI-120
(ii) Temperature sensor as suit to existing. Model No. MCST100
(iii) Gas sensor as suit to existing. Model No. MCST100
(iv) Eliminator for oil filteration as suit to existing
(v) Dryer make: denfoss of size 3/8"
(vi) Solenoid switch as suit to existing.
(vii) LP/HP cut out switch suitable for existing AC plant cap 120TR.
(viii) Pressure gauge (0-150 psi) analog type with stainless steel syphon suitable for HVAC plant of capacity 120 TR as existing.
(ix) Replacement of leaked/damaged copper tubes of chiller unit
(x) Repair to PCB assy as per Existing
(xi) Mechanical Flow Switch
Material and Labour for servicing and testing complete of 5/7.5/10 TR compressor package type unit with replacement of worn out /unserviceable parts and re fixing the same after complete servicing with accessories such as nut, bolts, washers etc. including testing, commissioning complete to the entire Satisfaction of Engr-in-charge Note :- (i) Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction. Testing shall be done for leak test, vaccum test, insulation, HV, wiring and performance test with complete test report with actual reading and read standerd parameter reading duly signed by HVAC maint Engineer/Tech of reputed firm. All spares parts as required for repair /servicing shall be measured and paid separately under relevant item of Schedule 'A'.
Material only for replacement of following parts/items suitable for 5/7.5/10 TR package type units against item no.4 (i) Fan belt s for blower motor as per existing size.
(ii) Bearing of shaft of blower 36mm dia as suit to existing
(iii) Complete wiring Resetting of Package Unit
(iv) Dryer filter 3/8''
(v) Air filter of 5 / 7.5/10 TR package unit as suitable for existing unit
(vi) Condenser fan blade suitable for existing unit
(vii) LP switch suitable for existing AC plant cap 5/7.5/10 TR (Package type) .
(viii) HP switch suitable for existing AC plant cap 5/7.5/10TR TR (Package type).
(ix) Repair to PCB assy as per Existing
S&F in replacement of Scroll type sealed compressor cap. 13 TR model No. SZ185S4RC, 380-400 V, 50 Hz thermally protected systemvolume 31.0L at LP side and 2.0 L at HP side PS from 25 bar to 31.9 bar make Danfoss suitable for existing AC plants
S&F in replacement of compressor cap. 5 TR any type 380-400 V, 50 Hz thermally protected system.
Servicing of Hot water Generator as per manufacturer norms of capacity 63 KW model No RC63, 3 steps any make complete all as specified and directed.
S&F in repair, heating coil as per sample of hot water generator of capacity 63 KW model No RC63, 3 steps any make as per sample complete all as specified and directed.
Material labour for replacement of following parts/items suitable for 22000/14000/4000 CFM capacity AHU unit of (i) Contactor 4 pole 40Amps
(ii) Contactor 4 pole 32 Amps
(iii) Temperature gauge mercury type suitable for HVAC system for hot/chilled water pipeline as existing with accessories .
(iv) Pressure gauge (96mm dia) analog type with stainless steel syphon suitable for HVAC plant of capacity upto 30 TR as existing.
(v) Digital Amps meter(0-32 Amps)
(vi) Fan belt for AHU as per existing.
(vii) Relay 8-22 Amps of existing.
(viii) Thermostat for AHU
Supply and fixing in repair of following spare parts of cooling tower motor of capacity 3 HP, 3 ph 415 Volts, 50 Hz, Make-Hindustan electric motor/Kirlosker (i) shaft with rotor
(ii) Bearing(deep groove) as existing size and model.
(iii) Immersion proof cable gland as existing.
(iv) Connecttion plate
(v) Outer casing with anti corrosion coating on the outside.
Material and labour for descaling of condenser, evacution of gas from the system after opening from both side and using the descaling compound and brushes with long iron rod to clean the deposition in side the copper tubes and check the water flow in side the tubes including replacement of gasket set, nuts and bolt all as directed by Engr-in-Charge. Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction. Following capacity are (a) 120 TR AC Plant
(b) 5 TR AC Plant.
(c) 35/25 TR AC Plant.
Material and labour for descaling of Chiller,cooling coils, after opening from both side and, removing the complete insulation and ereaasembing back ,including fillinf of fresh water, insulation testing complete as specified and directed. Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction. Following capacity are (a) 120 TR AC Plant
(b) 5 TR AC Plant.
(c) 35 TR AC Plant.
Material and Labour for cleaning, servicing of cooling tower with cleaning agent complete pipe lines, and FRP tank, greasing, servicing of cooling tower, motor and fan & make the necessary alignment Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction.for the following capacity are : (a) 240 TR AC plant
(b) 10 TR AC Plant.
(c) 70 TR AC Plant.
(d) 50 TR AC Plant.
Material and labour for replacement unserviceable ball bearing of Cooling Tower including all necessary lathe works as required and greasing etc complete as per direction of Engr-in-Charge. Following capacity of (a) 240 TR
(c) 70 TR AC Plant.
(c) 50 TR AC Plant.
Material and labour for repair/overhauling of centrifugal monoblock pump set motor of 5/7.5 HP by opening Gland bush , studs, nuts & washers Ball bearing of pump set Remetling grinding and polishing of pump shaft to required size Gland packing ,replacement of pump bearings and making its proper alignment etc & refixing after repair all as directed .
All as per item No. 15.00 here- in-before but 10.0 HP
Disconnecting the electrical connection and taking down the burnt out cooling tower motor of capacity 01/02/03 Hp from any location and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by EIC. Note :- Contractor must ensure reinstallation of motor and make motor functional after rewinding within 48 Hrs of receiving the complaint. Any delay will be fined Rs 1000 per hour
All as per item no 17.00 here in before but of capacity 10 Hp
Disconnecting the electrical connection and taking down the burnt out motor of monoblock pumpset of capacity 05/7.5 Hp from any location and transporting to workshop for repair, dismantling the pumpset & taking out burnout copper winding and rewinding the same with super enamelled copper wire as pr existing gauge including replacement of bering & correcting minor defects reassembling, transporting monoblock pumpset from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified and directed by EIC. Note :- Contractor must ensure reinstallation of pumpset and make the plant functional after rewinding within 48 Hrs of receiving the complaint. Any delay will be fined for Rs 1000 per hour
All as per item no 19.00 here in before but of capacity 02/03 Hp
All as per item no 19.00 here in before but of capacity 10 Hp
Material and Labour for repair/servicing greasing etc of condensor motor capacity upto 7.5/10 HP of repair / replacement of Ball bearing of motor and Remetling grinding and polishing of motor shaft to required size all as directed refixing the same with existing compressor with proper alignment.
Material and Labour for replacement unserviceable Nozzle spray set of Cooling Tower of capacity 35 to 70 TR complete all as specified and directed.
Dismantling and taking out old butterfly valve and supply, installation, testing and commissioning of butterfly valve class-II heavy duty for discharge & liquid line of 125/150 mm dia
Dismantling and taking out old butterfly valve and supply, installation, testing and commissioning of butterfly valve class-II heavy duty for discharge & liquid line of 200 mm dia
Dismantling and taking out old butterfly valve and supply, installation, testing and commissioning of butterfly valve class-II heavy duty for discharge & liquid line of 80 mm dia
Dismantling and taking out old butterfly valve and supply, installation, testing and commissioning of butterfly valve class-II heavy duty for discharge & liquid line of 100 mm dia
Supply and fixing in repair gun metal gate valve of size 25/32 mm dia complete all as specified and directed.
Dismantling and taking out old solenoid valve and supply, installation, testing and commissioning of solenoid valve class-II heavy duty for liquid line as per existing.
Material and labour for replacement unserviceable fan blade of out door unit package type AC plant of cap 5 TR complete all as specified and directed.
Supply and fixing in repair unserviceable CT fan blade of cooling tower of cap 70 TR as per existing size.
Supply and fixing in repair unserviceable CT fan blade of cooling tower of cap 240 TR as per existing size.
Material and labour for replacement of cooling pad /Fills for cooling tower/ air cooling plant including complete fitting as existing at various instalations.
Disconnecting & Taking out old existing unserviceable current transformer of Amp meter of any description and Supply, fixing & testing round/ring type current transformer of ratio 100/5 Amp to 150/5 Amp, rated burden 5 VA and accuracy class 1.0 complete all as specified & directed. Make : AE/Rishab/ Meco/Enercon/L&T/BCH.
Disconnecting, dismantling & taking out old existing unserviceable cables of any description & in any position and supplying, fixing & testing new Four core, PVC insulated, armoured unsheathed Aluminium conductor cables, size 50 Sqmm 4 core suitable upto 1100 Volts conforming to IS-694 complete all as specified & directed.
All as per item No. 38.00 above but cable of size 70 Sqmm 4 core
All as per item No. 38.00 above but cable of size 35 Sqmm 4 core
All as per item No. 38.00 above but cable of size 25 Sqmm 4 core
All as per item No. 38.00 above but cable of size 10 Sqmm 4 core
Supply and fix in replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same all as directed at site.
Supply and fix in replacement of single Phase Preventer suitable for motor protection and making all incoming and out going electric connections complete all a specified and directed.type VSP2 Make : Minilec/Jepro.
Supplying and fixing in replacement of AC contactor 3/4 pole, 415 volts current rating 32 A and including making necessary electric connections and testing of circuit on full load complete all as specified and directed. Make : BCH or equivalent in C&S or L&T.
All as per item No. 45.00 but current rating 18 AMPs, 3/4 pole -ditto-. Make -Siemens/ or equivalent of ABB or C&S.
All as per item No. 45.00 but current rating 125 AMPs, 37 KW, 3/4 pole -ditto-.Make- BCH/ or equivalent of siemens or L&T/ABB.
All as per item No. 45.00 but current rating 63 AMPs, 4pole -ditto- make BCH or equivalent of siemens or L&T/ABB.
Taking out old unserviceable MCCBs up to 200 Amp rating and Supply and fixing for MCCB, 4 pole,415Volt, 16 KA including cable lugs of suitable size Make: L &T/ Schneider/Legrand, complete testing, commissioning complete to the entire satisfaction of Engr-in-charge, the following capacity of (a) 63 Amps.
All as per above Item no. 49.00 but current rating 100 Amps
All as per above Item no. 49.00 but current rating 125 Amps
Supply and fix in replacement of overload relay capacity 4-11 Amp for motor protection making all incoming and outgoing electric connection complete all as specified and directed. Make : BCH or equivalent in C&S or L&T.
Supply and fix in replacement of overload relay capacity 8-22 Amp for motor protection making all incoming and outgoing electric connection complete all as specified and directed. Make : BCH or equivalent in C&S or L&T.
Supply and fix in replacement of overload relay capacity 16-44 Amp for motor protection making all incoming and outgoing electric connection complete all as specified and directed. Make : BCH or equivalent in C&S or L&T.
Supply and fix in replacement of timer for motor starter 0-30 sec./3-30 Sec making all incoming and outgoing electric connection complete all as specified and directed.Cat No-800 SD Make : Selec or equivalent in BCH /Angel
Supply and fixing in replacement air filter of AHU of size as existing suitable for AHU of following capacity :- (i) 4000/6000 CFM
Material and Labour for repairing /servicing / cleaning complete of hot water generator capacity of 115 KW, complete with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge Make: Emerald Enterprises. Note :- Servicing work of hot water generator unit to be done by the authorised representative of OEM. All spares and parts are required for repair /servicing are including.
Material and Labour for repairing/servicing / cleaning complete of Air Handiling Unit capacity of 14000 CFM, complete with replacement of worn out /unserviceable parts and rectify the leakages and reassembling the same after complete repair/leakages with accessories as nust, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge
All as per item No. 58 above but capacity of 22000 CFM
All as per item No. 58 above but capacity of 20750 CFM
All as per item No. 58 above but capacity of 4000 CFM
All as per item No. 58 above but capacity of 12000 CFM
All as per item No. 58 above but capacity of 6000 CFM
Taking out old damaged Ac duct insulation and supply and fixing for duct insulation with Alluminium laminated XLPE insulation of thickness 13 mm and including the following: (a) M & L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust,grease and other foreigen material, taking special care so that all duct joints are sealed against any leakages. (b) M & L for appling rubber based adhesive CPRX compound.
S&F in repair, axial fan for cooling of ACB panel of central AC plant(KACH) 220V AC metal body axial fan 4"/6" sweep as per existing as specified and directed by Engineer-in-Charge.
S&F in repair, temperature sensor for compressor/chiller unit of central AC plant (signal centre) tube sensor 125 C Model No. Vw-1H (08.0) & VIT-300 E218405, 105 C Vw-1 as per existing model with testing and commissioning complete as directed by Engineer-in-Charge.
M&L for preparation of old painted metal surfaces with 1 coat of aluminuim red oxide primer and 2 coats of aluminuim paint.all as per direction of engineer-in-charge.
Material and Labour for repairing/ servicing/ cleaning complete of 25 TR capacity chiller unit of Voltas / Blue Star make complete with replacement of worn out/ unserviceable parts and ressembling the same after completer repair with accessories as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete.
(i) Compressor oil R1 407 A
(ii) Temperature sensor as suit to existing. Model No ACWCDS026DPMN2X1P
(iii) Gas sensor as suit to existing
(iv) Dryer for 25 TR capacity chiller make: denfoss of size 3/8"
(v) Solenoid switch as suit to existing.
(vi) LP/HP cut out switch suitable for existing AC plant cap 25 TR Make :Denfoss/Indfoss
(viii) Pressure gauge analog type with stainless steel syphon suitable for HVAC plant of capacity 25 TR as per make
Material and Labour for repair/servicing greasing etc of condensor motor capacity upto 3 to 7.5 HP of repair / replacement of Ball bearing of motor and Remetling grinding and polishing of motor shaft to required size all as directed refixing the same with existing compressor with proper alignment.
Material and labour for descaling of condenser, chiller,evacuation of gases 25 TR AC Plant after opening from both side and using the descaling compound and brushes with long iron rod to clean the deposition in side the copper tubes and check the water flow in side the tubes including replacement of gasket set, nuts and bolt all as directed by Engr-in-Charge. Note :- Condensor/Chiller coil cleaning by Basic chemical of approved make with preventing equipment from cleanser and avoiding any hazard to human being from chemical reaction.
Servicing of Hot water Generator as per manufacturer norms of capacity 24 / 30 KW model No RC 24 / 30, 2 steps any make complete as directed and specified by EIC.
Material and Labour for repairing /servicing / cleaning complete of hot water generator capacity of 65 KW, complete with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories as nut, bolts, washers etc installation on existing foundation coupling with existing electrical motor with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-Charge Make: Emerald Enterprises. Note :- Servicing work of hot water generator unit to be done by the authorised representative of OEM. All spares and parts are required for repair /servicing are including.
S&F in repair, heating element / coil as per sample of hot water generator of capacity 24 / 30 KW model No RC 24 / 30, 2 steps any make as per sample complete as directed and specified by EIC.
Material labour for replacement of following parts / items suitable for 6000/8000/9000 CFM capacity AHU unit of Make - Voltas / Blue Star :-
(i) Contactor 4 pole 40 Amps
(ii) Contactor 4 pole 32 Amps
(iii) Temperature gauge suitable for HVAC system for hot/chilled water water pipeline as existing with accessories Make : H Guru
(iv) Pressure gauge analog type with stainless steel syphon suitable for HVAC plant as existing make: H Guru
(v) Digital Amps meter
(vi) Fan belt for AHU as per existing. Make : Fenner
(vii) Relay 8-22 Amps of existing make-L&T
(ix) Thermostat for AHU
M&L for rewinding of blower fan motor of capacity 5.0/7.5 HP with all accessories required for installing and connection complete all as specified and directed by EIC.
Supply and fixing in replacement air filter of AHU of size as existing suitable for AHU of following capacity :-
(iii) 12000 CFM
(iii) 9000 CFM
Supply and fixing in repair unserviceable CT fan blade of cooling tower of capacity upto 25 TR as per existing size.
Material and labour for replacement of unserviceable sluice valve flanged of class1.6 PN of 80 mm dia and necessary fittings
Supply and fix in replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same all as directed at site.
Supply and fix in replacement of Three Phase Preventer suitable for motor protection and making all incoming and out going electric connections complete all a specified and directed.type VSP2 Make : Minilec/Jepro.
Supply and fixing in replacement GI/MS pipes heavy duty of following sizes including taking down/up of existing pipe and replacing the same with new pipe incl welding work, providing all type of GI fitting as required at site including testing for leakage/blockage of pipe complete all as specified and directed by EIC :-
(i) 25 mm dia
(ii) 32 mm dia
(iii) 40 mm dia
(iv) 50 mm dia
(v) 80 mm dia
(vii) 125/150 mm dia
(viii) 200 mm dia
Taking out old damaged AC duct insulation and supply and fixing for duct Alluminium thickness of 22 Gauge and including the following:- (a) M & L for cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust,grease and other foreigen material, taking special care so that all duct joints are sealed against any leakages. (b) M & L for appling rubber based adhesive CPRX compound.
Taking out old rusted alluminium cladding and Supply and fixing alluminium sheet as per existing size for cladding to exposed AC duct rectangular/ square duct made out of Hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolts, gasket, with support of angle iron of size 50mm x 50mm x 6 mm and appropriate sealant on longitudinal joints etc as specified.
M&L checking of split type three phase air conditioner of any make / capacity 7.5/5.5/3.76/ 3.0 in location and position at any site in AA Jodhpur including necessary servicing ie: electrical connection /wiring, Capacitors, condenser, blower fan motor, Gas Pressure, both end bushes of approved quality ,cooling coil , micro filter and testing for proper functioning of split type air conditioner.
M&L Servicing of split type three phase air conditioner (Duct / cassette) of any make / capacity 7.5/5/5.5/3.76/ 3.0/ in location and position at any site in AA Jodhpur including necessary servicing ie: electrical connection /wiring, Capacitors, condenser, blower fan motor, Gas Pressure, both end bushes of approved quality ,cooling coil , micro filter and testing for proper functioning of split type air conditioner.
M&L for Leakege detection,pressuring complete system of following capacity Central Ac plants(packages/chiller type)Split Duct type three phase , casettte type air conditioner, checking leakage and flushing out system , rectification of leakages.Note- Gas and Oil to be paid seperately.
(i) 120 TR AC plant
(iii) 7.5/5/5.5 TR
M & L for disconnecting, existing U/S sealed unit and with new three phase hermatic sealed rotary compressure cap -3.5/3.76 ton/4.0 ton ( for duct/casette type) Note- Gas charging to be paid seperately.
M & L for disconnecting, existing U/S sealed unit and with new three phase hermatic sealed rotary compressure cap 7.5/8.5 ton ( for split type ACs) Note- Gas charging to be paid seperately.
Supply & charging only refrigerant gas as per existing. (for Ductable ACs/Casette ACs)
M&L for replacement of overload protection (OLP) for 3 Phase A.C (7.5/5.5/3.5/4Ton) as per site existing make and model complete all as specified and directed by Engr-in-charge.
S&F blower motor of indoor unit for 3/3.5Ton cap split type AC
S&F blower motor of indoor unit for 4 TON cap split type AC(Cassette )
S&F PCB for indoor unit of three phase split type Acs(casettte/duct)
S&F PCB for Out door unit of three phase split type Acs(casette/duct)
S&F contactor for outdoor unit of Single phase split type Acs
S&F fan motor of outdoor unit for 5/5.5/7.5 Ton cap Three phase split type AC
S&F fan motor/Blower motor for out door for 3/3.5/4 TON cap three phase split type AC
M&L for layout diagram of AC plant(package/chiller) type with detailed description including writing MES no. with capacity, date of installations along with Display Board at AC plant with location complete all as specified and directed.
M&L for replacement of copper suction/discharge tubes of appropriate size for 3 phase Acs including Insulation cover all as directed and specified by Engr-in-charge.
NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
PANWAR ELECTRICALS (BID ID -3487652)
RUHI ASSOCIATES (BID ID -3482295)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_826830.xls
BOQ • 8.13 MB
TENDERDOCUMENTS.pdf
Tender Documents • 1.99 MB
Download all tender documents and submit your bid