Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAdmitted-Finance DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Admitted-Finance | |
| 2 | L2₹38.4 L+₹50,578.04 (1.33%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹39.1 L+₹1.2 L (3.10%)Admitted-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L3 | Admitted-Finance | |
| 4 | L4₹39.8 L+₹1.9 L (4.90%)Admitted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L4 | Admitted-Finance | |
| 5 | L5₹40.3 L+₹2.4 L (6.31%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MSN ENGINEERING WORKS L3 | SAI SREENIVASA ENGINEERING L6 | SIRI CONSTRUCTION L5 | R AND A ASSOCIATES ENGINEERS CONTRACTORS L2 | M/S SRI VENKATA BHAVANI CONSTRUCTIONS L4 | B SRINIVAS L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for dismantling and taking out all cable connection from all switchgear and earthing connection of the indoor /outdoor panel board, removing carefully the complete panel board of size not less than 2.5 M x 2 M using sufficient man power /cranes from base of panel and keeping aside, re-construction of damaged panel foundation as per ground requirement in same place or other specified location with brick-work, plaster, foundation bolt, white wash to new plastered surface, reinstallation of complete panel and necessary cable end connection with suitable size of lugs/glands to respective cable/ switchgears, earthing complete all as specified and directed. | 1 | Job | 5,000 ₹5,000 | 4,000 ₹4,000 | 6,040 ₹6,040 | 8,000 ₹8,000 | 7,200 ₹7,200 | 1,000 ₹1,000 Lowest |
| 1.01Note- (i) Relaying of cables due to change of foundation of panel and Brick work/plaster work shall be incl in quoted rate by contractor (ii) Required additional length of cables shall be measured and paid separately, (iii) Cable joints if require will be measured and paid separately, (iv) Required aluminium cable lugs /glands, nuts, bolts and washers, foundation bolts, white wash will be inclusive of quoted rate | |||||||||
| 2.00 | S & F Hot dip Galvanised wire mesh cable trays 105 x 300 complete with tray, coupler, cover and cover clip to support clamps, securing properly to support strcture complete including dismantling existing LT cable of off sizes from building wall more than 3 mtr height form FL and relaying the same in proper alignment complete all as specified and directed. | 20 | RM | 600 ₹12,000 | 1,300 ₹26,000 | 1,900 ₹38,000 | 300 ₹6,000 | 1,900 ₹38,000 | 200 ₹4,000 Lowest |
| 3.00 | Supply, laying in cable trey/wall & connection PVC XLPE insulated, armoured havey duty electric cable with aluminium conductor, 1100 Volts grade cross section area 10 Sqmm 4 core incl dismantling taking down unsv one from wall, cable tray, trench complete all as specified and directed. | 150 | RM | 175 ₹26,250 | 195 ₹29,250 | 136 ₹20,400 Lowest | 160 ₹24,000 | 150 ₹22,500 | 193.52 ₹29,028 |
| 4.00 | All as per item No. 3.00 above, but of size 16 sqmm, 4 core. | 250 | RM | 190 ₹47,500 | 222 ₹55,500 | 172 ₹43,000 | 260 ₹65,000 | 170 ₹42,500 Lowest | 210.04 ₹52,510 |
| 5.00 | All as per item No. 3.00 above, but of size 25 sqmm, 4 core. | 350 | RM | 230 ₹80,500 | 250 ₹87,500 | 271 ₹94,850 | 285 ₹99,750 | 210 ₹73,500 Lowest | 248.98 ₹87,143 |
| 6.00 | All as per item No. 3.00 above, but of size 35 sqmm, 4 core. | 350 | RM | 312 ₹1,09,200 | 302 ₹1,05,700 | 307 ₹1,07,450 | 325 ₹1,13,750 | 270 ₹94,500 Lowest | 339.84 ₹1,18,944 |
| 7.00 | All as per item No. 3.00 above, but of size 50 sqmm, 3.5 core. | 350 | RM | 370 ₹1,29,500 | 390 ₹1,36,500 | 370 ₹1,29,500 | 440 ₹1,54,000 | 310 ₹1,08,500 Lowest | 397.66 ₹1,39,181 |
| 8.00 | All as per item No. 3.00 above, but of size 70 sqmm, 3.5 core. | 300 | RM | 500 ₹1,50,000 | 570 ₹1,71,000 | 490 ₹1,47,000 | 520 ₹1,56,000 | 430 ₹1,29,000 Lowest | 542.8 ₹1,62,840 |
| 9.00 | All as per item No. 3.00 above, but of size 120 sqmm, 3.5 core. | 350 | RM | 825 ₹2,88,750 | 870 ₹3,04,500 | 730 ₹2,55,500 | 800 ₹2,80,000 | 580 ₹2,03,000 Lowest | 750 ₹2,62,500 |
Tender Value
₹47.9 L
EMD Value
₹95,700
Closing Date
8 Sept 2026, 6:30 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIR, MAINTENANCE AND SERVICING OF LT PANEL BOARDS AND INCLUDING REPLACEMENT OF SWITCH GEARS PANEL METERS INSTALLED AT CERTAIN BUILDINGS AND ALLIED WORKS AT ZONE 6 7 8 AND 9 AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) DM VISAKHAPATNAM
2026_MES_784022_1
8573/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹95,700
Yes
10 Sept 2026
11 Aug 2026
10 Sept 2026
11 Aug 2026
8 Sept 2026
25 Aug 2026
12 Aug 2026 - 22 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for dismantling and taking out all cable connection from all switchgear and earthing connection of the indoor /outdoor panel board, removing carefully the complete panel board of size not less than 2.5 M x 2 M using sufficient man power /cranes from base of panel and keeping aside, re-construction of damaged panel foundation as per ground requirement in same place or other specified location with brick-work, plaster, foundation bolt, white wash to new plastered surface, reinstallation of complete panel and necessary cable end connection with suitable size of lugs/glands to respective cable/ switchgears, earthing complete all as specified and directed. | 1 | Job | - | - |
| 2 | S & F Hot dip Galvanised wire mesh cable trays 105 x 300 complete with tray, coupler, cover and cover clip to support clamps, securing properly to support strcture complete including dismantling existing LT cable of off sizes from building wall more than 3 mtr height form FL and relaying the same in proper alignment complete all as specified and directed. | 20 | RM | - | - |
| 3 | Supply, laying in cable trey/wall & connection PVC XLPE insulated, armoured havey duty electric cable with aluminium conductor, 1100 Volts grade cross section area 10 Sqmm 4 core incl dismantling taking down unsv one from wall, cable tray, trench complete all as specified and directed. | 150 | RM | - | - |
| 4 | All as per item No. 3.00 above, but of size 16 sqmm, 4 core. | 250 | RM | - | - |
| 5 | All as per item No. 3.00 above, but of size 25 sqmm, 4 core. | 350 | RM | - | - |
| 6 | All as per item No. 3.00 above, but of size 35 sqmm, 4 core. | 350 | RM | - | - |
| 7 | All as per item No. 3.00 above, but of size 50 sqmm, 3.5 core. | 350 | RM | - | - |
| 8 | All as per item No. 3.00 above, but of size 70 sqmm, 3.5 core. | 300 | RM | - | - |
| 9 | All as per item No. 3.00 above, but of size 120 sqmm, 3.5 core. | 350 | RM | - | - |
| 10 | All as per item No. 3.00 above, but of size 240 sqmm, 3.5 core. | 620 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
8573Tender.pdf
Tender Documents • 0.99 MB
BOQ_878466.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .