Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | ₹13.5 L Quoted ₹13.8 L | L1 | Accepted-AOC L1 AND REASONABLE |
| 2 | L2₹14.6 L+₹82,792 (6.00%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹14.6 L+₹82,792 (6.00%) | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹14.9 L+₹1.1 L (7.86%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | ₹14.9 L+₹1.1 L (7.86%) | L3 | Rejected-Finance NOT L1 |
| 4 | L4₹17.9 L+₹4.1 L (29.9%)Rejected-Finance | ₹17.9 L+₹4.1 L (29.9%) | L4 | Rejected-Finance NOT L1 |
| 5 | L5₹23.6 L+₹9.8 L (70.7%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | ₹23.6 L+₹9.8 L (70.7%) | L5 | Rejected-Finance NOT L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Oct 2023, 6:00 pmClosed
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
REPAIRS/ REPLACEMENT OF EXISTING UNSERVICEABLE OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES AND OTHER ALLIED WORKS IN MD ACCN AT SECTOR A, C AND OTHER AREA OF AGE E/M (ARMY) JAMNAGAR UNDER GE (ARMY) JAMNAGAR.ARMY) JAMNAGAR UNDER GE (ARMY)
2023_MES_620194_1
8027
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY JAMNAGAR
₹40,000
4 Dec 2023
22 Sept 2023
21 Oct 2023
23 Sept 2023
19 Oct 2023
6 Oct 2023
Amount
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed by Engr-in-charge.
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed by Engr-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed by Engr-in-charge.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(e) One bell point controlled by one, bell switch 5 Amps
(f) One light point controlled by one, two way switch 5 Amps
Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed by Engr-in-charge.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including drawn through in and including heavy duty, PVC casing caping including all accessories etc of white/ ivory colour including all accessories heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(e) One bell point controlled by one, bell switch 5 Amps
Description all as per item No 6 here in before but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed by Engr-in-charge.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
(c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(e) One bell point controlled by one, bell switch 5 Amps
(f) One light point controlled by one, two way switch 5 Amps
Description all as per item No 8 here in before but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed by Engr-in-charge.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and as directed by Engr-in-charge.
S & F for Modular Switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified and as directed by Engr-in-charge.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and as directed by Engr-in-charge.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed by Engr-in-charge.
S & F for Modular Switch Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed by Engr-in-charge.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete complete all as specified and as directed by Engr-in-charge.
S & F for for Bell push modular 6 Amps single module complete all as specified and as directed by Engr-in-charge.
S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified and as directed by Engr-in-charge.
S & F for Switch piano flush type, single pole, one way, and 15 Amp complete all as specified and as directed by Engr-in-charge.
S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified and as directed by Engr-in-charge.
S & F for socket outlet multipurpose combination, 2 in 1, 3 pin 5 and 15 amp flush type universal complete all as specified and as directed by Engr-in-charge.
S & F for Bell push 6 amp 230 volt 50 HZ AC supply complete all as specified and as directed by Engr-in-charge.
S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified and as directed by Engr-in-charge.
Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed by Engr-in-charge.
S & F for for Lamp holder, PVC body of brass suitable for batten fitting complete all as specified and as directed by Engr-in-charge.
S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified and as directed by Engr-in-charge.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 4.0 sqmm cable and one run of PVC heavy duty conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6.0 sqmm cable,one run of 6.0 sqmm cable and one run of PVC heavy duty conduit will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size 6.0 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including with two runs of PVC insulated 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- four runs of 6.0 sqmm cable, two runs of 6.0 sqmm cable and one run of PVC heavy duty conduit will be measured as one unit.
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engr-in-charge.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engr-in-charge.
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engr-in-charge.
S & F for MCB Single pole and neutral rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curvecomplete all as specified and as directed by Engr-in-charge.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 V breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engr-in-charge.
S & F for wall mounted LED box type tube light fitting 4' x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed by Engr-in-charge.. Make :- Make Bajaj Cat part No BCLAB 20W LED P S, Wipro Cat part No LL24R-251-XXX-57-XX or its equvalent in Philips Cat part No BN100C LED20S-6500 PSU L120 GR S4 or Havells.
S & F wall mounted LED 3/6 watts bed side lamp with necessary electrical connections complete all as specified and as directed by Engr-in-charge.
S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and including provosion of LED bulb 10/11 watts complete all as specified and as directed. Make- Havells Cat part No -LHGLO6160099 or its equivalent in Wipro, Philips, Bajaj
S & F for LED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting with warranty option of 5 years from date of installationcomplete all as specified and as directed.Make :- Bajaj or its equvalent in Wipro, Philips, Havells.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with warranty option of 5 years from date of installation and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with warranty option of 5 years from date of installation including LED bulb complete all as specified and as directed. Make :- Bajaj Cat No BIBWP 10W LED, Wipro Cat part No LW07-141-XXX-57-G1 or its equvalent in Philips Cat part No WT202W LED6S NW PSU S2 PC.
S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting with warranty option of 5 years from date of installation including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Make :- Bajaj Cat part No ENXT P 30L WH CR PC SD, or its equvalent in Wipro Cat part No LR02-291-XXX-57-XX, Philips Cat part No BRP042 P LED25 CW SLE S1 PSU GR P4210.
Fixing only light fitting of any type obtained from item No 1 with necessary electrical connections complete all as specified and as directed by Engr-in-charge.
S & F for Highly efficient LED Bulbs, 10 watts in B-22 cap complete all as specified and directed . Make Bajaj, Havells, HPL
S & F for for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for metal flush box made of GI sheet with earh terminal including necessary cutting in wall and POP work as required for matching existing slot in wall of size 4 module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for metal flush box made of GI sheet with earh terminal including necessary cutting in wall and POP work as required for matching existing slot in wall of size 6/8 module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for metal flush box made of GI sheet with earh terminal including necessary cutting in wall and POP work as required for matching existing slot in wall of size 10/12 module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for modular plates white colour with frame of 4 module including removal of old unserviceable one complete complete all as specified and as directed by Engr-in-charge.
S & F for modular plates white colour with frame of 6/8 module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for modular plates white colour with frame of 10/12 module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, piano flush type 2 module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5 Amp, piano flush type 2 module including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for for modular Bell push modular 6 Amps single module complete all as specified and as directed by Engr-in-charge.
S & F for for lamp holder, PVC body of brass suitable for batten fitting including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for ceiling rose, surface Bakelite suitable ISI marked for batten fitting including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable complete all as specified and as directed by Engr-in-charge.
S & F for MCB Single pole and neutral rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed by Engr-in-charge.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and as directed by Engr-in-charge.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and as directed by Engr-in-charge.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and as directed by Engr-in-charge.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 6 Sqmm from sub main wiring including removal old existing unserviceable one complete all as specified and as directed by Engr-in-charge.
S & F wall mounted LED box type tube light fitting 4' x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including removal old existing unsv light fitting complete all as specified and as directed by Engr-in-charge.. Make :- Make :- Make Bajaj Cat part No BCLAB 20W LED P S, Wipro Cat part No LL24R-251-XXX-57-XX or its equvalent in Philips Cat part No BN100C LED20S-6500 PSU L120 GR S4 or Havells.
S & F for LED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting ith warranty option of 5 years from date of installation including removal old existing unsv light fitting complete all as specified and as directed by Engr-in-charge. Make :- Bajaj or its equvalent in Wipro, Philips, Havells.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in grond (earth pit not less than 2.25 mtrs below normal ground level) with the top edge of the plate not less than 1.5m below the normal ground level connected to GI wire 4.00mm dia protected by 15mm bore GI pipe light grade) and watering pipe 20mm bore GI pipe (medium grade) and chamber PCC (1:4:8) type D2( using 40mm grade stone aggregate), MS FUNNEL with wire mesh ,coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and RCC (1:2:4) type B1 using 20mm graded stone aggregate, pit cover 50mm thick reinforced with 8 mm MS bar at 80mm c/c both way in lieu of CI pit cover with lifting hook including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No-3 of SSR part-I and as specified including earth plate packed around with charcoal dust common salt complete including GI sheet funnel, wire mesh, earth lead wire 4mm dia and earth lead connected to earthing test point/ main board. The GI earth wire 8 SWG under the earth and on pole/db upto a height of 1.5m shall also be protected by 15mm dia GI pipe (light grade ) and the GI pipe to be fixed with poles/wall by means of 02 Nos. FI clamp 25x3mm with nuts bolts and washer etc. incl taking down old earthing complete all as specified and directed by Engineer-in-Charge. Note :- GI earthing wire and protected pipe 15 mm dia of same size upto 7.5m shall deemed to be included into quoted rate
BHAVNA IMPERIAL ENTERPRISE
Rameshwar Enterprise
M/s. Vimal Enterprise
fakhrie apostrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .