| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC H NO 765 VPO BIHTA TEHSIL BARARA DISTRICT AMBALA 133101 | AMBALA | AMBALA | HARYANA | 133101 | ₹28.3 L | L1 | Accepted-AOC AOC |
| 2 | L2₹29.5 L+₹1.2 L (4.32%)Rejected-Finance HOUSE NO 43 VPO KOT DISTRICT PANCHKULA 134118 | PANCHKULA | PANCHKULA | HARYANA | 134118 | ₹29.5 L+₹1.2 L (4.32%) | L2 | Rejected-Finance Highest |
| 3 | L3₹29.9 L+₹1.6 L (5.62%)Rejected-Finance H NO 787 22 JHANG COLONY ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹29.9 L+₹1.6 L (5.62%) | L3 | Rejected-Finance Highest |
| 4 | L4₹31.9 L+₹3.6 L (12.6%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹31.9 L+₹3.6 L (12.6%) | L4 | Rejected-Finance Highest |
| 5 | L5₹32.0 L+₹3.7 L (13.1%)Rejected-Finance AMAR NIWAS RA 288 GANDHI CHOWK SADAR BAZAR KARNAL | KARNAL | KARNAL | HARYANA | ₹32.0 L+₹3.7 L (13.1%) | L5 | Rejected-Finance Highest |
Tender Value
₹36.4 L
EMD Value
₹72,780
Closing Date
14 Aug 2023, 11:00 amClosed
NAVEEN RATHEE
ED - Ambala
Pdg. 250 KVA Sub Station at CHC Radaur in Distt. Yamuna Nagar.
2023_HRY_300464_1
202331BF855C 2D67 4286 B23F 0F1193E97D09663BAR
Open Tender
Civil Works
Works
75 days
Ambala Cantt
Pdg. 250 KVA Sub Station at CHC Radaur in Distt. Yamuna Nagar.
2 documents required · 2 mandatory
₹5,000
₹72,780
Yes
19 Oct 2023
28 Jul 2023
14 Aug 2023
28 Jul 2023
14 Aug 2023
28 Jul 2023
Amount
[20.84]Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge
[20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects.
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
[23.22.1.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA
[23.22.1.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA
[23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm
[23.23.7.1]MISCELLANEOUS 7.1. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 100 X 50 X 2 mm
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
[24.2.5.2]LT CABLE 5.2. Laying and fixing of cable on surface/ cable tray etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core
[24.2.5.3]LT CABLE 5.3. Laying and fixing of cable on surface/ cable tray etc as required:- 50 Sq mm to 150 sqmm 2 to 4 Core
[24.2.5.4]LT CABLE 5.4. Laying and fixing of cable on surface/ cable tray etc as required:- 185 sqmm to 240 sqmm 3 to 3½ Core
[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core
[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core
[24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core
[24.3.1.1]HT CABLE 1.1. Laying and erection of XLPE (E)II kv HT aluminium conductor armoured cable 1 metre below ground level with sand & bricks with all labour and material including digging and refilling of trench as required up to 120 sqmm 3 core XLPE Cable
[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia
Supply and erection of lighting arrestor model ISI Marked suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resistar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Supply and Erection MS bucket stand which including cost of 6 nos. buckets of 9 liter capacity with sand filling including cost of welding and painting of complete stand and buckets with one coat of red oxide and two coats of approved paint of red colour with all labour and petty material to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work.
Supply, Erection , testing and commissioning of 11 KV outdoor type HT Metering panel complete with CTs, PTs cubical, and electronics Meter with accuracy class 0.2 as per requirement / approved by UHBVN. Panchkula Electrical Supply consists of following : i) Cubical panel free-standing floor mounting type made of sheet steel 14 G SWG CRCA sheet with channel iron base frame spray-painted with strong synthetic grey channel paint as per size and design approved by UHBVN. PANCHKULA Electrical Supply.Outdoor Type with outer canopy. ii) 3 nos. 11 KV CTs of 0.2 S accuracy (rating as per requirement given by UHBVN Panchkula). iii) 1 no. 11 KV PTs 11000/110 volts 10 VA burden 0.2 accuracy suitable for indoor installation of approved make of UHBVN Panchkula Electrical Supply. iv) Digital electronics meter 3 Phase 4 wire 11000 / 110 volts 10 VA burden 0.2 accuracy for recording reading of KWH of make and rating approved by UHBVN Panchkula Electrical Supply with push-button display operating system for different kind of readings. v) Foundation of Suitable Size 300mm above ground level made of CC having the suitable size to hold the metering panel vi) Outer housing fab by 2mm thick CRCA sheet to cover the HT Metering Panel from rainwater alongwith agnle iron frame. vii) The cubical panel will be complete in all respect including interconnections, internal wiring with PVC copper cable its testing/approval of all items by UHBVN Panchkula Electrical Supply with a guarantee of one year from the date of commissioning including the cost of all labour and material required to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work.
Supply , Erection , testing and comissioning of Stey Set for GO Switch complete in all respect i/cost of Disc insulator etc. upto the entire satisfaction of Engineer -in Charge of work.
Supply, Erection, testing and commissioning of GI Fancing 7.5 Feet High From Finish Floor Level supported with GI Angle/ Channel complete in all repect upto the entire satisfaction of Engineer -in Charge of work.
S/E of PCC Pole 9 Meter long 105mm x 115mm at top and 105mm x 315mm at the bottom (as per IS 1678-1960) with a working load of 200kg buried 1.80 m in-ground with all satisfaction of EIC of work . Make as per UHBVN.
Supply of Aluminium Armoured HT XLPE cable of size 70Sqmm 3 Core, Make as per approved list
Supply of Aluminium Armoured LT cable of size 25 Sqmm 3.5 Core, Make as per approved list
Supply of Aluminium Armoured LT cable of size 35 Sqmm 3.5 Core, Make as per approved list
Supply of Aluminium Armoured LT cable of size 50 Sqmm 3.5 Core, Make as per approved list
Supply of Aluminium Armoured LT cable of size 70 Sqmm 3.5 Core, Make as per approved list
Supply of Aluminium Armoured LT cable of size 95 Sqmm 3.5 Core, Make as per approved list
Supply of Aluminium Armoured LT cable of size 150 Sqmm 3.5 Core, Make as per approved list
Supply of Aluminium Armoured LT cable of size 240 Sqmm 3.5 Core, Make as per approved list
S/I/T/C of 250 KVA, 11/0.433 KV Cast Resin Dry type transformer with off circuit tap link as per ECBC 2007/2017, Make Voltamp, vector group dyn11, frequency 50 Hz taping range in step plus 5% to -5% in step of 2.50% each, tap changer off circuit tap link, temperature rise (winding) above ambient 90 degree C, losses at 50% load 1700 w (max) as per ECBC 2007/2017 losses at 100% load 4320 w (max) as per ECBC 2007/2017, impedance at 75 degree C 4.00% (IS TOL) and enclouser protection class IP-23 for indoor and including cable box inbuilt HV/LV side complete in all respect upto the entire satisfaction of Engineer - in - Charge of work.
M/S GARG ELECTRICAL
Janta Electric Store
M/s JSB Enterprises
Som Nath Contractor
M/s Balaji Electric Works
Shree Shyam Associates
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .