Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹28.3 L+₹55,000 (1.98%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER | |
| 3 | L3₹30.8 L+₹3.1 L (11.2%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER | |
| 4 | L4₹31.8 L+₹4 L (14.4%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER | |
| 5 | L5₹33.8 L+₹6.0 L (21.8%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L5 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | SANJOLI CONSTRUCTION COMPANY L4 | Bharat Enterprises L2 | Shri Electrical Enterprises L5 | SMT Construction L3 | Vijaypower Generators Limited L1 | M/s R K Enterprises L6 | Chamunda construction company L7 | NISHA CONSTRUCTIONS L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply,installation, testing and commissioning of Retrofitted emmision control device (RECD) approved by CPCB for family of DG set and should have COP suitable for 100 kVA Diesel Generator set of any make complete all as specified and directed and having following specifications:- • DG safety Alarm system included
• Material Construction - SS304
• Temperature Indication and monitoring
• Pressure Indication and monitoring
• PM Capture/PM reduction capacity 85-90%
• High Heat Resistance
• Low exhaust Resistance
• Easy to Install.
* Durability period should be 4000 hrs or 12 years whichever is earlier
Make/ Manufacturer : Cummins Technologies India Pvt Ltd / Inventive Gas Equipment / PI Green Innovations Pvt Ltd/Novorbis Itus Pvt Ltd Note: (i) Emission test report of engine before and after installation should be submitted by the contractor (ii) Device Should be type Approved CPCB for family of DG sets and required (iii) Contractor should submit OEM authorization Certificate (iv) The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. A manual valve be given after the first stage ( Oxidation stage) and before the second stage (Passive Regeneration Trap) of the DOFF, Noise attenuation is with in the permissible limits, Equipped with mechanical pressure relief system, capturing chamber made of resistance process, treated mild steel etc. as required.(v) The RECD device provided by the seller should be equipped with a remote Data Monitoring system certified by ICAT/ ARAI providing essential information recorded at every 15 minutes, including but not limited to :
a. Energy consumption. b. Running Hours. c. warning related to ECD diagnosis for the following conditions:
* Complete loss of particulatecapture function.
* Removal of the ECD system.
* Failure of ECD system.
* Detection of exhaust bypass, temporary or permanent, as part of field/ operator tampering.
(vi) Engine performance and noise level should not be effected after the installation of the RECD. (vii) Contractor and RECD manufacture should visit DG set for the selection of RECD (viii) The installation work of Emission Control Retrofit Device includes any type of support structure mechining, Tools & Plants and materials required and deemed to be included in the quoted rate. (ix) Details of RECD installed to ne labelled on DG set after installation as per CPCB standards. (x) Operators to trained and safety instruction and operating proceedures to be displayed after the installation of RECD. (xi) Drawing of RECD should be approved by acceptig officer before execution. (xii) Half yearly Maintenance with back purge upto defect liability period is deemed to be included in the quoted rate.(xiii)Factory visit of device by Engineer in charge for approval is required before installation which is to be arranged by contractor. (xiv) Servicing of DG sets, replacement of filters etc if required for the proper functioning of RECD to be carriede out by the contractor and deemed to be included in the quoted rate. | 3 | Each Job | 3,51,000 ₹10,53,000 | 2,70,000 ₹8,10,000 Lowest | 3,43,175 ₹10,29,525 | 3,52,632 ₹10,57,896 | 2,85,000 ₹8,55,000 | 3,47,500 ₹10,42,500 | 3,33,700 ₹10,01,100 | 3,70,155 ₹11,10,465 |
| 2.00 | All as per item No 1 above but suitable Retrofit Emission Control Device for 125 kVA Diesel Generator set of any make complete all as specified and directed. | 2 | Each Job | 3,90,000 ₹7,80,000 | 2,90,000 ₹5,80,000 Lowest | 3,75,135 ₹7,50,270 | 3,67,643 ₹7,35,286 | 3,12,000 ₹6,24,000 | 3,70,500 ₹7,41,000 | 3,90,000 ₹7,80,000 | 4,01,333 ₹8,02,666 |
| 3.00 | All as per item No 1 above but suitable Retrofit Emission Control Device for 200 kVA Diesel Generator set of any make complete all as specified and directed. | 2 | Each Job | 4,41,000 ₹8,82,000 | 4,30,000 ₹8,60,000 | 4,83,795 ₹9,67,590 | 3,87,654 ₹7,75,308 | 3,12,000 ₹6,24,000 Lowest | 5,00,000 ₹10,00,000 | 5,37,900 ₹10,75,800 | 5,27,315 ₹10,54,630 |
| 4.00 | All as per item No 1 above but suitable Retrofit Emission Control Device for 160 kVA Diesel Generator set of any make complete all as specified and directed. | 1 | Each Job | 4,24,000 ₹4,24,000 | 3,80,000 ₹3,80,000 | 4,00,412 ₹4,00,412 | 3,76,543 ₹3,76,543 | 3,12,000 ₹3,12,000 Lowest | 3,95,000 ₹3,95,000 | 4,19,300 ₹4,19,300 | 4,55,250 ₹4,55,250 |
| 5.00 | Supply and installation of DG AMF controller with LCD display to monitor multiple parameters, universal compatibility, button lay out with labelled terminals and self start function including all control wiring and installation kit with silicone gasket for sealing and detailed installation manual for settings all as specified and directed. | 8 | Each Job | 4,500 ₹36,000 Lowest | 25,000 ₹2,00,000 | 29,000 ₹2,32,000 | 17,432 ₹1,39,456 | 45,000 ₹3,60,000 | 33,500 ₹2,68,000 | 35,000 ₹2,80,000 | 37,974 ₹3,03,792 |
Tender Value
₹34.8 L
EMD Value
₹69,540
Closing Date
6 Jan 2026, 6:00 pmClosed
OFFG AGE (C)
Military Engineer Services, Garrison Engineer (Army) No 2 Jodhpur, Multan Lines, Army Area Jodhpur -342010
PROVISION OF RECD ON GENERATOR SET UNDER GE (ARMY) NO 2 JODHPUR
2025_MES_744693_1
8800/25-26/66/04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (ARMY) NO 2 JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (ARMY) NO 2
₹69,540
Yes
18 Mar 2026
16 Dec 2025
8 Jan 2026
16 Dec 2025
6 Jan 2026
30 Dec 2025
16 Dec 2025 - 23 Dec 2025
All as per item No 1 above but suitable Retrofit Emission Control Device for 125 kVA Diesel Generator set of any make complete all as specified and directed.
All as per item No 1 above but suitable Retrofit Emission Control Device for 200 kVA Diesel Generator set of any make complete all as specified and directed.
All as per item No 1 above but suitable Retrofit Emission Control Device for 160 kVA Diesel Generator set of any make complete all as specified and directed.
Supply and installation of DG AMF controller with LCD display to monitor multiple parameters, universal compatibility, button lay out with labelled terminals and self start function including all control wiring and installation kit with silicone gasket for sealing and detailed installation manual for settings all as specified and directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
TENDER66.pdf
Tender Documents • 0.86 MB
BOQ_833854.xls
BOQ • 1.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .