| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC CHAKKALAKKAL H KOTTAT P O | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.9 L+₹1.6 L (25.4%)Rejected-Finance AROOR P O ALAPPUZHA KERALA 688534 | ALAPPUZHA | ALAPPUZHA | KERALA | 688534 | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | BIJU JOSE L1 | KELTRON LIGHTING DIVISION L2 |
|---|---|---|---|---|---|
| 1.00Mini mast lights | |||||
| 1.00 | 90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters | 7 | each | 29,000 ₹2,03,000 | 26,524.75 ₹1,85,673.25 Lowest |
| 1.00 | 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 20 | each | 8,500 ₹1,70,000 Lowest | 11,513.87 ₹2,30,277.4 |
| 1.00 | 90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 8 | each | 9,800 ₹78,400 Lowest | 13,956.8 ₹1,11,654.4 |
| 1.00 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 16 | cum | 300 ₹4,800 | 190.32 ₹3,045.12 Lowest |
| 1.00 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). | 2.3 | cum | 4,500 ₹10,350 Lowest | 4,519.86 ₹10,395.68 |
| 1.01 | 14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. | 2.1 | cum | 4,500 ₹9,450 Lowest | 4,684.8 ₹9,838.08 |
| 1.01 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels | 21 | sqm | 90 ₹1,890 Lowest | 208.86 ₹4,386.06 |
| 1.01 | OD485305/2024-2025:Supply and providing tor steel rod for reinforced cement concrete including cutting bending and
tying in shape as required | 130 | kg | 85 ₹11,050 Lowest | 122.76 ₹15,958.8 |
| 1.01 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board | 28 | kg | 65 ₹1,820 Lowest | 146.4 ₹4,099.2 |
Tender Value
₹12.7 L
EMD Value
₹19,771
Closing Date
29 May 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Thrissur corporation
Executive Engineer Thrissur corporation
Thrissur Corporation 24-25 Ayyanthole Zonal Division 46 - Installation of Flood Light in AKG Ground and Fixing Minimast Lights in Various Places -Project no S0591/25-
2025_LSGD_765704_12
PW2-17409/18,31.5.25,EE2
Open Tender
Civil Works - Others
Item Rate
180 days
Thrissur corporation Office
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,745
₹19,771
22 Dec 2025
22 May 2025
31 May 2025
22 May 2025
29 May 2025
22 May 2025
22 May 2025 - 27 May 2025
Amount
Mini mast lights
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD485305/2024-2025:Supply and providing tor steel rod for reinforced cement concrete including cutting bending and tying in shape as required
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.5.13:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 6 sq mm
9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
OD485298/2024-2025:Supply and fitting in the existing light pole bottom box 6A TP connector for the power tool control and giving connections etc complete.
OD485301/2024-2025:Supply and fitting in the existing Control panel 24 hours Analog Timer switch supply voltage 230 V 50 Hz for operating automatic on/off function with IP53 grade protection, operating temperature 10 º C - 50º C, contact>16 A for controlling -main contactor-1 Nos and giving connections etc complete.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD485297/2024-2025:Supply and fitting in the existing Control panel 16A, 4P contractor for the power tool control and giving connections etc complete.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD485302/2024-2025:Supply and providing 4 pole enclosure for independent mounting of MCB/RCCB/Isolator etc. as required
OD485299/2024-2025:Providing independent Ordinary pipe earthing using 1.00 meters of 40 mm dia GI pipe ,earth wire copper and other specials such as common salt ,charcoal bolts and nuts etc. complete required at site.
90.16.4.1:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).20 x 3 mm GI strip
OD485306/2024-2025:Supply and providing the following sizes of bolt and nut with washers on the existing MS box/earth bus etc. as required including necessary holes as required. 25x3mm brass nut and bolt
OD485307/2024-2025:Supply and Fixing 32 A, 2 Way neutral links mounted on DMC/SMC base
OD485303/2024-2025:Supply and providing 32 A HRC fuse unit with HRC fuse link in the meter box and giving connections as required
OD485300/2024-2025:Supplying and fixing of meter box weather proof type (make Sintex IP 67) of size 540x320x200 mm with 2 compartment, for providing single phase energy meter, fuse unit, Isolator, RCCB, Analog Timer. Meter box fixing on the pole using suitable clamps with bolts and nuts etc complete.
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
OD485304/2024-2025:Preparing completion and test certificates for KSEB connection
KELTRON LIGHTING DIVISION (BID ID -2217746)
Bidder Name
BIJU JOSE
KELTRON LIGHTING DIVISION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1248088.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .