| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹26.9 L+₹2.4 L (9.90%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹31.0 L+₹6.4 L (26.3%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹33.5 L+₹9.0 L (36.7%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹33.6 L+₹9.0 L (36.9%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-T-03/2022-23 REPAIRS / MAINTENANCE OF ELECTRICAL WIRING, DISTRIBUTION BOARDS AND ALLIED ITEMS IN MD AND OTM ACCOMMODATIONS IN DOMESTIC AREA AT AF STATION AMBALA UNDER GE (AF) AMBALA
2022_MES_530444_1
GE AF/AMB-T-03/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹80,000
Yes
12 Sept 2022
13 Jun 2022
21 Jul 2022
13 Jun 2022
19 Jul 2022
28 Jun 2022
20 Jun 2022 - 24 Jun 2022
Amount
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
M&L for concealed point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed on walls, ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 6A one way switch
One switch socket outlet 3 pin 6A on independent board
One switch socket outlet 3 pin 5A on same board
One bell point controlled by one bell push
One light point controlled by two way switch
M&L for concealed point wiring with 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, concealed in walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for one switch socket combination outlet 5 pin 15/16A multipurpose complete all as specified and as directed
M&L for concealed point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through existing PVC conduit, concealed on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 6A one way switch
One switch socket outlet 3 pin 6A on independent board
One switch socket outlet 3 pin 5A on same board
One bell point controlled by one bell push
One light point controlled by two way switch
M&L for concealed point wiring with 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100V grade with multistranded copper conductor drawn through existing PVC conduit, concealed in walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly complete all as specified and as directed for multipurpose switch socket combination outlet 5 pin 15/16A complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC casing capping not less than 20mm wide and accessories surface on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly with MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 6A one way switch
One switch socket outlet 3 pin 6A on independent board
One switch socket outlet 3 pin 5A on same board
One bell point controlled by one bell push
M&L for point wiring with 2.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC casing capping not less than 20mm wide and accessories surface on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly with MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for multipurpose switch socket combination outlet 5 pin 15/16A complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 5A, 230V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 15A, 230V complete all as specified and as directed
S&F socket outlet, 5 pin, multipurpose 6A modular type, ISI marked, 230V complete all as specified and as directed
S&F socket outlet, multi-purpose, 3 pin, 16A, and 3 pin 6A, modular type, ISI marked, 230V controlled by one switch complete all as specified and as directed
S&F electronic fan regulator, stepped modular type (5 steps), 120W, 1 module, 50Hz, 230V, ISI marked with cover plate duly connected up complete all as specified and as directed
S&F modular white cover plate with frame ISI marked complete all as specified and as directed suitable for the following:
1/2 modules
3/4 modules
6 modules
8 modules
S&F modular metal flush box ISI marked complete all as specified and as directed suitable for the following:
1/2 modules
3/4 modules
6 modules
8 modules
S&F switch piano flush button type, single pole, ISI marked, one way 6A, 240V complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, two way 6A, 240V complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 15A, 240V complete all as specified and as directed
S&F socket outlet, 5 pin, multipurpose 5A flush type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, 2 in 1, 3 pin, multipurpose 15A flush type, ISI marked, 240V complete all as specified and as directed
S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and as directed
S&F bell push flush button type, 5A, 240V complete all as specified and as directed
S&F bell buzzer, ding dong type, 230V, single pole complete all as specified and as directed
S&F in repairs PVC plate round cover 4" to 6" dia of approved colour complete all as specified and as directed
S&F driver 230V suitable for 40/45W LED garden lights of existing make and type complete all as specified and as directed
S&F driver 230V suitable for 45/60W LED light fittings of existing make and type complete all as specified and as directed
S&F driver suitable for LED strip of 1/3/5W of existing make and type complete all as specified and as directed
S&F LED strip 1W flexible type warm white in colour 10mm width of approved deisgn, make and type complete all as specified and as directed
S&F in repairs 3mm thick hylam sheets duly fixed complete all as specified and as directed of the following sizes:
4x5inch
8x5inch
10x5inch
10x8inch
10x12inch
S&F LED tube light fitting 1x18W, box type, 230V, PF 0.95, input voltage 90-300V, CRI> 70, L 80, in commercial channel with powder coated CRCA sheet housing with and including LED tubelight with high efficient LED in aluminium housing with clear & milky diffuser with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod including taking out and disposing old fitting any type complete all as specified and as directed
S&F in repairs indoor decorative LED batten with opal diffuser with inbuilt LED tube 10W and driver designed with high transmitting optics for even light distribution IP 20 degree protection having length 620mm and PF 0.95, CRI> 70, L 80 and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed
S&F in repairs recess/surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36W, input voltage 90-300V, PF 0.95, CRI> 70, L 80 with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod complete all as specified and as directed
S&F in repairs LED bulk head 10W with pressure die cast aluminium housing high efficient LEDs and enclosed with milky diffuser IP 66 protection, input voltage 90-300V, PF 0.95, CRI> 70, L 80 stranded luminaries with efficiency 100 lumen/Watt, with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed
S&F LED tube rod 1x18W, PF >0.95, input voltage 90-300V, IP-68, LM 80 stranded luminaries efficiency 100 lumen/watt, 230V with all accessories and taking down old fitting from any position complete all as specified and as directed
Supplying, installation and testing LED bush light 6W (warm white) and input voltage 230VAC, 50Hz with cast aluminium housing with toughened glass IP-66 including fixing arrangements into wall/ pillar with necessary connection of suitable sized copper conductor cable and and taking down and disposing off old unserviceable light fittings complete all as specified and directed
S&F in repairs aesthetically disigned LED post top lantern 15W, input voltage 230VAC, 50Hz with die cast aluminium spigot & prismatic diffuser, IP-65/66 protection class including fixing arrangment like suitable clamps, nut, bolts and washers and connecting up with suitable sized of copper conductor cable complete all as specified and as directed
S&F LED light fitting 45W with lamp, with input voltage 110 to 280V, alongwith auto-shutdown on high voltages, life min-5000hrs, operating temperature 1 to 50o, IP-66 protection class, comprising of rectangular shaped pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment, system wattage of 100W=10%W, with rated lumens of minimum 5000lumens with 120o view angle, constant driver current having THD<10%, power factor >0.95, with short circuit protection, reverse circuit protection, high voltage protection, 10kV high surges, having secondary optics with perfectly matched lenses conforming to IEC60598 / IS10322 with all accessories pre-wired and connecting with twin core twisted flexible 3 core 1.0sqmm copper conductor cable, fitted duly with and including GI bracket fabricated with 40mm bore light grade GI tubing, duly cut to size and shape required at site and taking down and disposing old fitting complete all as specified and as directed
S&F in repairs recess mounting low height backlit round LED down light of 15W of existing make/model complete all as specified and as directed
S&F in repairs recess mounting low height backlit round LED down light of 18W of existing make/model complete all as specified and as directed
S&F in repairs recess mounting low height backlit square LED down light of 6W of existing make/model complete all as specified and as directed
S&F in repairs recess mounting low height backlit square LED down light of 3W of existing make/model complete all as specified and as directed
S&F in repairs LED post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection of 40W with necessary connection of multistranded copper conductor complete all as specified and as directed
S&F in repairs gang box suitable for mounting of 6/16W switches / sockets with necessary copper conductor cable complete all as specified and as directed of the following sizes:
2 modules
4 modules
6 modules
8 modules
12 modules
Supplying, fixing in position, installing and testing pressure pumps 0.5HP, single phase, 230V including taking up/down old unserviceable pressure pump and disposing off complete all as specified and as directed
S&F auto-cut pressure release valve suitable for pressure pump of capacity 0.5 -1.0HP as per existing including taking down and disposing off old valve complete all as specified and as directed
S&F in repairs casing caping of size 20mm wide with all necessary fittings viz. bends, angles, stoppers, etc. complete all as specified and as directed
S&F LED lamp 9W 230V complete all as specified and as directed
S&F LED lamp 7W 230V complete all as specified and as directed
M&L for disconnecting, dismantling and taking out pressure pump of capacity 0.5 -1.0HP at site, transporting to reputed workshop, rewinding the pressure pump with the same gauge of copper winding wire with same number of turns as existing and re-assembling the pump after carrying out necessary repairs, replacing unserviceable spares part like bushes, shafts, fasteners, bearings, capacitors and copper wire to ensure serviceable condition and refixing the same at original location complete all as specified and as directed Note: Spare parts, etc. required for repairing, rewinding the motor of the pump, etc. as required shall be deemed to be included in the quoted rate
S&F in repairs sheet metal enclosures for 4 way MCCB incomer + 12 module outgoings, vertical type, TPN, load line distribution board with provision for mounting of MCCB 100A as incomer, double door IP 43 protection class conforming to IS 8623-III, with 160A rated bus bar, blanking plates duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 415V, TPN, 4 way, double door type, flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V, SPN, 12 way, double door type flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V, SPN, 8 way, double door type flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V, SPN, 4 way, double door type flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs MCCB, four pole, 415V, 100A, 16kA complete all as specified and as directed
S&F in repairs MCB TPN, 415V, 63A, 'B' curve, 10kA complete all as specified and as directed
S&F in repairs MCB SPN, 240V, 5 to 40A, 10kA, 'B' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F in repairs MCB SP, 240V, 5 to 32A, 10kA, 'B' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F in repairs plug top, 15A capacity 240V, single phase including connecting up complete all as specified and as directed
S&F PVC body, air freshner 200/230mm sweep single phase 230V including louvers and fixing arrangement as per site requirement complete all as specified and as direcected
Supplying, fixing / laying in repairs PVC insulated aluminium conductor cable, 2 core 6sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in service connections complete all as specified and as directed
Supplying, fixing / laying in repairs PVC insulated aluminium conductor cable, 2 core 10sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in service connections complete all as specified and as directed
S&F in repairs PVC 2 core chord, flexible copper insulated cable 24/0.2mm size black/grey in colour and fixed / laid complete all as specified and as directed
S&F in repairs PVC insulated single core copper conductor cable laid / fixed complete all as specified and as directed of the following sizes:
S&F three phase electronic tamper proof, digital electric meter, CT operated with CT ratio of 100/5 energy meter for LT supply, accuracy class 1.0, 415V, -/5A conforming to IS: 13779, duly fixed in suitable Engineering plasticbox with locks including taking down old / unserviceable meter any type complete all as specified and as directed
S&F single phase electronic tamper proof digital energy meter of rating 10 to 60A fixed in transparent hinged box conforming to IS: 13779 including taking down old / unserviceable meter any type complete all as specified and as directed
S&F three phase electronic tamper proof digital energy meter of rating 5 to 30A fixed in transparent hinged box conforming to IS: 13779 including taking down old / unserviceable meter any type complete all as specified and as directed
Notes for item Nos. 102 to 104: Old / unserviceable electric meters taken down shall be deposited at MES store and rate quoted shall be deemed to be inclusive of all loading/unloading and carting, etc. as required
S&F heavy duty, metallic body with metallic blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 300mm sweep with lauvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts including taking down old / unserviceable fan any type complete all as specified and as directed
S&F energy efficient BEE five star rated ceiling fan, 230/240V, single phase, 1200mm sweep and connecting up with provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to ceiling fan including taking down old / unserviceable fan any type complete all as specified and as directed
Note for item Nos. 106 to 107: Old / unserviceable exhaust fans and ceiling fans taken down shall be deposited at MES store and rate quoted shall be deemed to be inclusive of all loading/unloading and carting, etc. as required
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 10sqmm and 1 run of 6sqmm multistranded, copper conductor cable 1100volts green colour for earth conductor drawn through and including PVC conduit 32mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
Notes for item Nos. 109 to 111: (i) 2 runs of 4/6/10sqmm main cable, 1/2 runs of earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe GI 15mm bore light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item Nos. 113: (i) The cost of GI earth continuity wire / strip with GI pipe 15mm light grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
The Rahul Vig
sanjeev enterprises
R N Enterprises
M/S Sonu Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .