Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC Y 51 GROUND FLOOR OKHLA INDUSTRIAL AREA PHASE 2 OKHLA NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | L1 | Accepted-AOC Selected | |
| 2 | L2₹7.9 L+₹18,790 (2.42%)Rejected-AOC MAGANINE M 8 M 9 HARSHA HOUSE COMMERCIAL COMPLEX KARAMPURA NEW DELHI DELHI 110015 HARSHA HOUSE KARAMPURA COMMERCIAL COMPLEX KARAMPURA COMMERCIAL COMPLEX KARAMPURA COMMERCIAL COMPLEX | WEST DELHI | DELHI | 110015 | L2 | Rejected-AOC Selected | |
| 3 | L3₹9.3 L+₹1.6 L (20.2%)Rejected-AOC 810 VISHWASADAN TOWER DISTRICT CENTRE JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | L3 | Rejected-AOC Selected | |
| 4 | L4₹10.2 L+₹2.5 L (31.9%)Rejected-AOC | L4 | Rejected-AOC Selected | |
| 5 | L5₹11.4 L+₹3.7 L (47.1%)Rejected-AOC S 79 OKHLA INDUSTRIAL AREA PHASE II NEW DELHI 110020 | SOUTH EAST | DELHI | 110020 | L5 | Rejected-AOC Selected |
Tender Value
₹12.6 L
EMD Value
₹25,150
Closing Date
4 Dec 2018, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Providing and fixing FM 200 Fire Suppression Systems in Room No. 7, A-Block, Ist floor at State Consumer Disputes Redressal Commission, Vikas Bhawan, I.P.Estate, New Delhi.
2018_PWD_162411_1
93 /EE (E)/PWD DHC and ND/Central /2018-19
Open Tender
Electrical Works
Works
30 days
New Delhi.
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹25,150
29 Sept 2020
24 Nov 2018
4 Dec 2018
24 Nov 2018
4 Dec 2018
24 Nov 2018
Amount
A) Fire Suppression System Supplying, installation, testing and commissioning of following capacity seamless Cylinder for Novec 1230 fluid complete with valve, pressure gauge, syphon tube, pressure switch etc. complete as required and having the approval of P.E.S.O./ Chief controller of explosives, Nagpur etc as required. a) 80 Liters
b 34 Liters
Supplying, installation, testing and commissioning of Novec 1230 fluid and as per Specification, UL listed & UL marked etc as required.
Supplying, installation, testing and commissioning of Master Cylinder Accessories, such as Pressure Guage, Low Pressure guage, Supervisory Switch, Electromagnetic Actuator, Manual Actuator, Neumatic Actuator, Flexible Discharge Hose, Flexible Actuation Hose, UL listed & UL marked etc. complete as required
Supplying, installation, testing and commissioning of Novec 1230 fluid Discharge Nozzle, 180/360° (As per flow calculation) with fittings, UL listed & UL marked etc. complete as required
Supplying and Fixing of following diameter Piping M.S. Seamless Schedule 40 ASTM A-106 Grade B with necessary fittings and accessories, etc. complete as required. a) 40 mm
Supplying, installation, testing and commissioning of Gas Inhibit Push Button Unit to shift system from auto to manual. etc complete as required
Supplying, installation, testing and commissioning of Gas Manual Release Button Unit to discharge system from auto to manual. etc. complete as required
Supplying, installation, testing and commissioning of plug-in type ionization/optical addressable analogue smoke detectors with base plate & hardware for mounting and this will glow in case of Fire complete, as per specifications etc. complete as required, duly LPCB Approved.
Supplying, installation, testing and commissioning of dust and vermin proof addressable analogue manual call boxes with flashing LED with isolator to initiate audio visual alarm in case of human detection of fire complete, as per specifications, duly LPCB Approved etc as required
Supplying, installation, testing and commissioning of addressable loop sounder cum strobe with inbuilt isolator suitable for audio and visual alarm siren complete, as per specifications, duly LPCB Approved, etc as required.
Supplying, installation, testing and commissioning of addressable control module with inbuilt isolator required for various outputs to other systems like signal to switch off AHU, access control etc. complete, as per specifications, duly LPCB Approved etc as required
Supplying, installation, testing and commissioning of 2 core 1.5 sq mm stranded copper conductor FRLS 1100 volts grade sheathed cable including saddles, crimped terminations etc. for surface mounting as required.
Supplying, installation, testing and commissioning of Caution sign boards Complete etc as required
Supplying, installation, testing and commissioning of cylinder mounting bracket complete with clamps, bolts & fastners etc. complete as required
Supplying, installation, testing and commissioning of Microprocessor based with LCD display 2 Zone Fire Alarm Panel and one Area Gas Discharge module with battery charger and standby SMF battery etc complete as required
Supplying, installation, testing and commissioning of 1 loop (fire alarm capability: 1 loopx126 detectors with a minimum of required loops) wall/ recess mounting microprocessor based analogue addressable fire control panel with minimum 320 character LCD display, 2 access levels, 1000 events historical logging, flash Eprom, 240 volts as power supply, automatic battery charger, 24Volts sealed lead acid battery suitable for operating the system for at least 30 minutes in emergency condition. the panel shall have provision to incorporate the same in graphic software system to display all the fire & faults event on a single remote interface at main fire control room . The panel shall be duly LPCB be approved, as per specifications, etc as required.
b) Fire Extinguisher etc Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolator) a) 12 way, Double door
Supplying and fixing of 5 ampers to 32 ampers rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Providing and fixing of following rating and breaking capacity & pole MCCB with thermo magnetic release & terminal spreaders in existing cubicle panel board/DB including drilling holes in cubicle panel/DB, making connections, etc. as required. a) 125 Ampers, 16 kA, breaking capacity TPMCCB with thermal magnetic release & terminal spreaders (ICU= 100% ICS)
Supplying, Installation, testing & Commissioning of CO2 type fire extinguisher (Duly ISI Marked) confirming to IS: 15683 capacity 4.5 Kg complete with delivery hose horn, squeeze grip/wheel type release valve, locking arrangement, operation manual and bracket, operating temperature 30° C to +55°C complete etc as required
Supplying, Installation, testing & commissioning of ABC powder type fire extinguisher (stored pressure type) capacity 4 Kg (duly ISI Marked) confirming to IS: 15683:2006 with IS: 14609, complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operating manual and bracket, operating temperature 10° C to +55°C complete etc as required
FIRE HUT COMMERCIAL EQUIPMENT PVT.LTD.
M/s Royale Meridian India Pvt Ltd
FIRE REMEDY SYSTEMS
PYROGUARD ENGINEERS PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .