Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC | L1 | Accepted-AOC As L1 Bidder | |
| 2 | Rejected-Technical N D BLOCK BAGNAN 711303 | HOWRAH | WEST BENGAL | 711303 | - | Rejected-Technical Not Admitted | |
| 3 | Rejected-Technical 106 DR LALIT BANERJEE SARANI GROUND FLOOR KOLKATA 700073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | - | Rejected-Technical Not Admitted | |
| 4 | Rejected-Technical 86 SOMNATH LAHIRI SARANI KOLKATA 700 053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | - | Rejected-Technical Not Admitted |
Tender Value
₹42.2 L
EMD Value
₹85,000
Closing Date
4 Sept 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM(BTPS)
Administrative Building, Bandel Thermal Power Station, Tribeni, Dist Hooghly Pin712503
Biennial Maintenance or Rate Contract for maintenance of AC Machines at Plant and Township under jurisdiction of EM-IPH Dept., BTPS, WBPDCL
2020_WBPDC_292717_1
WBPDCL/BTPS/NIT/E1743/20-21
Open Tender
Support/Maintenance Service
Item Rate
730 days
Bandel Thermal Power Station
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹85,000
Administrative Building, Bandel Thermal Power Stn.
5 Feb 2021
14 Aug 2020
7 Sept 2020
14 Aug 2020
4 Sept 2020
22 Aug 2020
20 Aug 2020
120 days
Amount
AMC PART:
AMC for day to day maintenance, servicing & trouble shooting work for all Room A.C. machines of all capacity at BTPS Plant & Township, under EM-IPH dept by deploying 02 Nos. of Non-Listed Workers (including Tools and Tackles & Profit).
Cost of PPE
Cost of Tools & Tackles
ARC PART:
Replacement of the Compressor of 1 TR capacity Window type AC m/c including supply of the compressor
Replacement of the Compressor of 1. 5 TR capacity Window type AC m/c including supply of the compressor
Replacement of the Compressor of 2 TR capacity Window type AC m/c including supply of the compressor
Replacement of the Compressor of 1 TR capacity split type AC m/c including supply of the compressor
Replacement of the Compressor of 1. 5 TR capacity split type AC m/c including supply of the compressor
Replacement of the Compressor of 2 TR capacity split type AC m/c including supply of the compressor
Replacement of the Compressor of 4 & 4. 5 TR capacity Floor type AC m/c including supply of the compressor
Replacement of the Compressor of 5. 5 TR capacity Duct able type AC m/c including supply of the compressor
Repair of Control Card for Window type AC m/c of Capacity 1TR / 1. 5 TR / 2 TR
Repair of Control Card for Split type AC m/c of Capacity 1 TR/1. 5 TR / 2 TR
Repair of Control Card for Floor type AC m/c of Capacity 4 & 4. 5TR
Repair of Control Card for Duct able type AC m/c of Capacity 5. 5 TR
Replacement of Control Card including supply for 1 TR capacity Split/Window type AC m/c.
Replacement of Control Card including supply for 1. 5 TR capacity Split/Window type AC m/c.
Replacement of Control Card including supply for 2 TR capacity Split/Window type AC m/c.
Replacement of Control Card including supply for 4 & 4. 5TR capacity Floor type AC
Replacement of Control Card including supply for 5. 5 TR Duct able type AC m/c.
Fitting of ¼ inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of 1/2 inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of 5/8 inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of 3/4 inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of 3/8 inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of Copper tube Insulation per meter with supply.
Replacement of Suction Valve for Split/Window/Floor type AC m/c including supply.
Replacement of Discharge Valve for Split/Window/Floor type AC m/c including supply.
Replacement of Thermostat Switch for 1 TR / 1. 5 TR / 2 TR capacity Window/Split type AC m/c including supply.
Replacement of Thermostat Switch for 4 & 4. 5 TR capacity Floor type AC m/c including supply.
Fabrication of Frame with MS Flat, Angles, nut-bolts and then Erection & Mounting the Frame on wall for protection of 1 TR /1. 5 TR / 2 TR capacity Window type AC m/c, with supply of materials.
Fabrication of Frame with MS Flat, Angles, Erection & Mounting on wall for protection of 1 TR / 1. 5 TR / 2 TR capacity Split type AC Outdoor Unit with supply of materials.
Replacement of Total Copper Condenser coil for I TR / 1. 5TR Window type AC with supply.
Replacement of Total Copper Condenser coil for I TR / 1. 5TR split type AC with supply.
Replacement of Total Copper Condenser coil for 2 TR window type AC with supply.
Replacement of Total Copper Condenser coil for 2 TR split type AC with supply.
Replacement of Total Copper Cooling coil for I TR / 1. 5TR Window type AC with supply.
Replacement of Total Copper Cooling coil for I TR / 1. 5TR split type AC with supply.
Replacement of Total Copper Cooling coil for 2 TR window type AC with supply.
Replacement of Total Copper Cooling coil for 2 TR split type AC with supply.
Replacement of Total Copper Cooling coil for 4/4. 5 TR Tower AC & 5. 5 TR Ductable type AC with supply.
Repair of Copper Condenser coil for I TR / 1. 5 TR / 2 TR Window type AC.
Repair of Copper cooling coil for I TR / 1. 5 TR / 2 TR split type AC.
Replacement of Runner of I TR / 1. 5 TR / 2 TR Split type AC with supply.
Replacement of Runner of I TR / 1. 5 TR / 2 TR Window type AC with supply.
Replacement of Runner for 4/4. 5 TR Tower AC & 5. 5 TR Duct able type AC with supply.
Replacement of Fan/Blower Motor for window type AC 1 TR Capacity with supply.
Replacement of Fan/Blower Motor for window AC 1. 5 TR / 2 TR Capacity with supply.
Replacement of Fan/Blower Motor for Split AC 1 TR Capacity with supply.
Replacement of Fan/Blower Motor for Split AC 1. 5 TR / 2 TR Capacity with supply.
Replacement of Fan/Blower Motor for Floor AC 4 & 4. 5 TR Capacity with supply.
Replacement of Fan/Blower Motor for 5. 5 TR Duct able type AC with supply.
Replacement of Condenser Motor (Single phase, 0. 5 HP) for Ductable AC of 5. 5 TR Capacity with supply.
Replacement of cooling Motor (3 phase, 3 HP) for Duct able AC of 5. 5 TR Capacity with supply
Repair of Copper cooling coil for Duct able AC of 5. 5 TR Capacity
Replacement of Starting Relay for 1 TR / 1. 5 TR / 2 TR Split/Window AC with supply.
Installation/Replacement of 2 pole MCB at AC power line with supply of MCB, Make Havells, Rating 25 Amp
Installation/Replacement of 3 pole MCB at AC power line with supply of MCB, Make Havells, Rating 25 Amp
Extension of Electrical wiring for AC machine with 4 sq mm Copper wire (Make: Havells) with earthing in PVC casing / pipe per meter with supply of the wire, casing etc. wiring materials per meter.
Replacement of Starting/Running Capacitor with supply for 1 TR Window/Split type AC.
Replacement of Starting/Running Capacitor with supply for 1. 5 TR Window/Split type AC.
Replacement of Starting/Running Capacitor with supply for 2 TR Window/Split type AC.
Replacement of Strainer Capillary with supply for 1 TR / 1. 5 TR / 2 TR Split/Window Type AC machine.
Connection with supply of Drain pipe per meter for Split/Window/Floor type AC m/c of capacity 1 TR /1. 5 TR /2 TR.
AC machine Split / Window compressor repairing capacity 1 TR.
AC machine Split / Window compressor repairing capacity 1. 5 TR / 2 TR.
AC machine compressor repairing for 4/4. 5 TR Tower AC & 5. 5 TR Duct able type AC
Supply & Filling of gas R-22 / Mafron for Window Type AC machine Capacity 1 TR.
Supply & Filling of gas R-22 / Mafron for Window Type AC machine Capacity 1. 5 TR.
Supply & Filling of gas R-22 / Mafron for Window Type AC machine Capacity 2 TR.
Supply & Filling of gas R-22 / Mafron for Split Type AC machine Capacity 1 TR.
Supply & Filling of gas R-22 / Mafron for Split Type AC machine Capacity 1. 5 TR
Supply & Filling of gas R-22 / Mafron for Split Type AC machine Capacity 2 TR
Supply & Filling of gas R-22 / Mafron for Floor Type AC machine Capacity 4 & 4. 5 TR
Supply & Filling of gas R-22 / Mafron for Ductable Type AC machine Capacity 5. 5 Ton
Repairing/Rewinding of Blower Motor/Cooling Motor for Split/Window/Floor type AC Machine of capacity 1 TR /1. 5 TR /2 TR.
Repairing/Rewinding of Cooling Motor (3 phase, 3 HP) for Duct able type AC Machine of capacity 5. 5 TR.
Repairing/Rewinding of Condenser Motor (Single phase, 0. 5 HP) for Duct able type AC Machine of capacity 5. 5 TR.
Filter pad replacement of 1 TR / 1. 5 TR Split/Window type AC Machine with supply
Filter pad replacement of 2 TR Split/Window/Floor type AC Machine with supply
Filter pad replacement of 4/4. 5 TR Tower AC and 5. 5 TR Duct able type AC Machine with supply
Fan Blade replacement for Split / Window AC M/c of capacity 1TR /1. 5 TR /2 TR with supply.
Fan Blade replacement for Duct able type AC Machine of capacity 5. 5 TR with supply
Replacement of Front Grille for 1 TR /1. 5 TR /2 TR window type AC m/c with supply
Replacement of Flapper for 1 TR /1. 5 TR /2 TR window/split type AC m/c with supply
Replacement of Flapper motor/air swing motor for 1 TR /1. 5 TR /2 TR window/split type AC m/c with supply
V-Belt Replacement For 5. 5 TR capacity Duct able type A. C. with supply
Total Duct Cleaning For 5. 5 TR capacity Duct able type A. C. with supply of all required tools and accessories
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .