Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹3.2 L
EMD Value
₹6,490
Closing Date
19 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Construction of School Building at Middle School Kandoora Budgam B.W.O Electric work
2026_PWDJK_299715_1
NIT No.249/2025-26 Dt/01/01/2026
Open Tender
Electrical Works
Percentage
Kandoora Budgam
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹6,490
2 Jan 2026
2 Jan 2026
20 Jan 2026
2 Jan 2026
19 Jan 2026
2 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab /Finolex / RR Kabels /Anchor /Salzer make in recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of p/ f of Lighting Junction deep and fan deeps as per site requirement and as directed by EIC ) , with 6Amps modular switch, modular plate of Anti backteria series of Schneider /ABB /L&T /Legrand /Simens /Havels/ eq.make to be approved by EIC , suitable GI box and earthing the point with 1.5 s q.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( P+N+E for Normal and invertor points per room is to be provided seperately)
Wiring for lightl power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ) including alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. of Polycab /Finolex /Anchor /Kabels /Salzer / eq.make to be approved by EIC.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ) as required. of Polycab / Finolex /Anchor / RR Kabels /Salzer / eq.make to be approved by EIC.
2 X 1.5 sq. mm +1 X1.5 sq. mm earth wire
2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. ( Anti backteria series of Schneider /ABB /L&T /Legrand /Simens /Havels / eq.make to be approved by EIC , )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 2 No's of 3 pin 5/6 A modular socket outlet and 2 No's of 5/6 A modular switch, connections etc. as required. ( Anti backteria series of Schneider /ABB /L&T /Legrand/Simens /Havels / eq.make to be approved by EIC)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.( Anti backteria series of Schneider /ABB /L&T /Legrand / Simens /Havels / eq.make to be approved by EIC)
Supplying and fixing of 16 Amps Box type S-S Combine for invertor input and out put
Supply and fixing of 16 Amps 3-Pin Top of SSK /Eq.make
Supply and laying of 25 mm dia medium class PVC medium grade Conduit to berecessed on walls / floor complete with all allied accrues like bends, tees etc. for paving way of laying of wires of haeting points /circuits ,machine points /circuits and sub mains .The Job includes cutting of walls / floors with required hydraulic cutter and refacing of walls with cement plaster of required ratio or with P.O.P after laying of conduits refacing to its original position by way of supply and applying of painting of required colour to effected area's complete matching with existing surface .Anchor/Polycab/Finolex/TMT Plus /paraflex / eq.make to be approved by EIC.
Supply, Installation, Testing and Commissioning of 1200 mm sweep , 3 nos. blades, 30 cm long down rod, , suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. of Usha /havels /Crompton / Orient / eq.make to be approved by EIC
Supply, Installation testing and commissioning of 250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Havel's incl making of necessary connections and making of necessary space in walls / Windows as per site.The Job includes providing and fixing of shutter of suitable size backlite hylum sheet for fixing of exhaust fan of Usha /havels /Crompton / Helonix / eq.make to be approved by EIC
Supply and fixing of 12 Watts LED surface /recess downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). . The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver.of Philips /Trilux / Wipro / Helonix /Lighting techanology /Regent / eq.make to be approved by EIC
Supply ,Installation ,Testing and Commissioning of 1P 66, 50 Watt LED Flood Luminaries having Aluminium body of standard make dully isi marked ,to be fitted on walls / poles with necessary cliffs /Clamps with nuts and bolts complete job.The system efficacy of the luminaire shall be ≥120lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700°K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK07. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV, HV Cut off @ 325V (±15V). The luminaire shall have 10KV SPD in-built inside the luminaire.. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver.of Philips /Trilux / Bajaj / Helonix /Lighting techanology / eq.make to be approved by EIC
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) of Legrend / L&T / ABB /Simens /schinder / eq.make to be approved by EIC
4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens / eq.make to be approved by EIC
Supplying and fixing of 40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens / eq.make to be approved by EIC
Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder / eq.make to be approved by EIC dully isi marked complete with connections
Supplying and fixing of 125 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder / eq.make to be approved by EIC dully isi marked complete with connections
Supply,Laying,Testing & Commissioning of 35 sq.mm 2- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/ grandleys /KEI/Eq make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections ,Including rolling of LT Colour coded types for main service line from LT pole
Supply and laying of DWC double layer Corrigated pipe having 50 mm dia to be laid partially under ground including execuation and refilling back and disposal of surplus earth or surface mounted with p/f of steel saddles complete job complete job.
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and laying of shock proof Rubber mats of 2mt. x 1 mt. and 12 mm thick in size
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_972441.xls
BOQ • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .