Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC HARIGAON PO NIKAMUL SATRA DIST SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹17.3 L+₹38,781 (2.29%)Rejected-Finance | L2 | Rejected-Finance other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Oct 2020, 6:00 pmClosed
GE AFS TEZPUR
GE AFS TEZPUR, PO- SALONIBARI, DISTT- SALONIBARI, ASSAM-784104
REPAIR AND MAINT OF CRANE, LIFT, VOLTAGE STABILIZER, FIRE HYDRANT AND OTHER CONNECTED MISC WORKS AT TEZPUR UNDER GE (AF) TEZPUR
2020_MES_374304_2
8517/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AFS TEZPUR
Class E cat b(i) or c(iii) or c(vi)
6 documents required · 6 mandatory
₹500
Yes
GE AFS TEZPUR
₹40,000
Yes
23 Nov 2020
5 Oct 2020
22 Oct 2020
5 Oct 2020
20 Oct 2020
6 Oct 2020
5 Oct 2020 - 5 Oct 2020
Amount
M&L for inspection / servicing of 2 Ton capacity Electrical Overhead traveller Cranes of any make installed at different buildings/location and making /keeping the cranes in serviceable condition complete all as specified and directed with and including the operations specified on PS clause No14 and 15.
M&L for inspection / servicing of 5 Ton capacity Electrical Overhead traveller Cranes of any make installed at different buildings/location and making /keeping the cranes in serviceable condition complete all as specified and directed with and including the operations specified on PS clause No14 and 15.
M&L for inspection / servicing of 10 Ton capacity Electrical Overhead traveller Cranes of any make installed at different buildings/location and making /keeping the cranes in serviceable condition complete all as specified and directed with and including the operations specified on PS clause No14 and 15.
M&L for inspection / servicing of 10 Ton capacity Flame proof Electrical Overhead traveller Cranes of any make installed at different buildings/location and making /keeping the cranes in serviceable condition complete all as specified and directed with and including the operations specifiedon PS clause No14 and 15.
M&L for inspection / servicing of 2 Ton capacity manually operated Overhead traveller Cranes of any make installed at different buildings/location and making /keeping the cranes in serviceable condition complete all as specified and directed with and including the operations specified on PS clause No14 and 15.
M&L for load testing complete for LT/CT/Hoist motion of the 2 ton EOT cranes(installed at eleven different location with in Technical Area complex) for 125% capacity using any type of dead weight ,complete all as specified and as directed. Note-1 Necessary weights shall be arranged by the MES Department . 2 Shifting of load at site and shifting to different buildings/locations with in TP complex using truck/mobile crane etc of suitable capacity shall be arranged by the contractor . 3 Tools, tackles ,chains and sling etc of suitable capacity required for load testing shall be arranged by the contractor. 4 Unit rate quoted shall be deemed to incl the cost of all above and no extra payment on this acount shall be made . Adjustment of brakes, motors,gear boxes, electrical system, load hook ,steel wire ropes , limit switches and all related item complete all specified and directed.
All as per item No.6 here-in-before but 5 ton capacity EOT crane installed at one building complete all as specified and directed.
All as per item No.6 here-in-before but 10 ton capacity EOT crane installed at one building complete all as specified and directed.
All as per item No.6 here-in-before but 10 ton capacity Flame Proof EOT crane installed at four building complete all as specified and directed.
All as per item No.6 here-in-before but 2 ton capacity Mannual operate crane installed at four building complete all as specified and directed.
Supply fixing and making all connection ,limit switch capacity 40 Amp 415 Volts all as per existing for LT/CT/ Hoist motion of 10 ton capacity FLP crane including taking down old unserviceable complete all as specified and as directed.
Supply and fixing flame proof thrustor unit complete as per existing capacity 18 Kg incl taking down the old unserviceable all as specified and as directed.
Supply only gear oil grade 680 suitable for reduction gear boxes Note: For item No. 1 to 5
Supply and fixing brake liner set suitable for 100 mm dia drum for LT/CT motion of 10 Ton capacity FLP crane complete all as directed and specified
All as per item No 14 here-in-before but 160 mm dia drum complete all as specified and as directed
Supply and fixing brake liner set suitable for 150 mm dia drum for hoist motion of 10 Ton capacity FLP crane complete incl taking down old unserviceable complete all as directed and specified
All as per item no 16 her in before but 200 mm dia drum complete all as specified and as directed
Supply and fixing torque spring suitable for 6 Kg capacity 100 mm dia drum brakes of LT/CT motion incl taking out the old unserviceable complete all as specified and as directed.
All as per item no 18 here-in-before but 9 Kg capacity and 160 mm dia drum for LT/CT/hoist motion complete all as specified and as directed.
All as per item no 18 here-in-before but 20 Kg capacity and 200 mm dia drum for hoist motion complete all as specified and as directed.
S&F air break contactor 12 amps coil voltage 110 volts 50 Hz complete incl taking out the old unserviceable complete all as specified and as directed. Make ABB/L&T/Seimens
All as per item No 21 here-in-before but 32 amps complete all as specifed and directed
All as per item No 21 here-in-before but 12 Amp Aux contactor complete all as specified and directed
All as per item No 21 here-in-before but 25 Amp Aux contactor complete all as specified and directed
All as per item No 21 here-in-before but 32 Amp Aux contactor complete all as specified and directed
M&L for MS coupling 25 mm dia with nuts ,bolts and bushes suitable for LT/CT motors incl taking out the old unserviceable all as directed.
All as per item No 26 here-in-before but 50mm dia for drive shafts complete all as specified and as directed
M&L for Rewinding of Hoisting Motor 10 HP by supper enamelled Copper winding wire of same gauge as existing one including heating, Varnishing and testing after complete all as specified and as directed.
All as per item No 28 here-in-before but 5 HP complete all asspecified and as directed
M & L for Serviceing and repairing of Oil Cooled Servo Voltage Stabilizer, 75 KVA thre phase, by disconnecting of all incomming and out going cable , opening of top cover carefully, cleaning of motor , service connection ,gear pininon, lifting of core from the tank by opening cover, cleaning of tank, removing the sediment, cleaning of coils / electrical connections, filtration of transformer oil,fixing the core back in the tank, making electrical connection by replacing the consumable spares such as gaskets, rubber oil seals complete etc but other spares as listed here-in-after shall be replaced and cost of spare parts as supply only shall be measured and paid separately under relevent item after that testing of servo voltage stabilizer in presence of Engr-in-charge , complete all as specified and as directed
All as per serial item no 30 here-in-before capacity 200 KVA 3 Phase
All as per serial item no 30 here-in-before capacity 250 KVA 3 Phase
All as per serial item no 30 here-in-before capacity 500 KVA /630 KVA 3 Phase Note for serial item no 30 to 33:- (i) Spare parts required to make serviceable of above oil cooled servo voltage stabilizer shall be measured and paid separately under relevent item here-in-after. (ii) Rewinding of barrier assembly and transformer assembly will be measured and paid separately.
Supply only Potentiometer.Make Volina/Hindustan/AE
Supply only Voltmeter (Digita). Make MECO, Havells,L&T,HPL/Crompton/AE
Ampere Meter with C. T. (Digital) Make MECO, Havells,L&T,HPL/Crompton/AE
Micro Processor Based Control Card for Each Phase.Make Volina/Hindustan/Servocon
Supply only P C B Holder.Make Volina/Hindustan/Servocon
Supply only Servo Motor 10 Kg Torque.Make Volina/Hindustan/Servocon
Supply only Servo Motor 20 Kg Torque.Make Volina/Hindustan/Servocon
Supply only Carbon Brush (20amps to 200 amps) Make Volina/Hindustan/Servocon
Supply only Carbon Holder & Spring.Make Volina/Hindustan/Servocon
Supply only Servo motor gear pinion.Make Volina/Hindustan/Servocon
Supply only R C Net work for 10 Kg Motor.Make Volina/Hindustan/Servocon
Supply only R C Net work for 20 Kg Motor.Make Volina/Hindustan/Servocon
Supply only Drive assembly 75 Kva per phase.Make Volina/Hindustan/Servocon
Supply only Drive assembly 200 KVA per phase.Make Volina/Hindustan/Servocon
Supply only Drive assembly 250 KVA per phase.Make Volina/Hindustan/Servocon
Supply only Digital Control Panel with Circuit board for high / low Voltage cut per phase suitable for 3 phase Voltage Stabilizer of capacity upto 75/200/250/500 630KVA.
Supply only front control with wiring kit .Make Volina/Hindustan/Servocon
M&L rewinding of Dimmer Starter (Barrier) for 75 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Complete all as specified and as directed
M&L rewinding of Dimmer Starter (Barrier) for 200/250 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Complete all as specified and as directed
M&L rewinding of Dimmer Starter (Barrier) for 500/630 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Complete all as specified and as directed
M&L Rewinding of Transformer assembly for 75 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Make Volina/Hindustan/Servocon
M&L Rewinding of Transformer assembly for 200/250 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Make Volina/Hindustan/Servocon
Comprehensive maintenance of fire fighting pumping installation installed at seven no different location , including minor repair of all parts involved for smooth operation/function of plant including greasing, cleaning, adjustment, minor repairs of nuts, bolts, washers etc of centrifugal fire fighting & jockey pump sets, DG sets of different capacity etc with other related equipments of the pump house/ installations alongwith valves including cleaning of inside and outside areas of the respective fire fighting pump houses, replacement of gland packing,coupling maintenance of suction and delivery pipe lines, primary fill up of priming tanks at different locations complete all as specified and as directed.
S&F in repair 63 mm dia and 15 m long canvas hose conforming to IS 636 complete including male& female coupling complete all as specified and as directed .
Comprehensive maintenance of fire fighting control panel for starting of water pump, jockey pump,mainpump by replacing of burnt control wiring, contactor ,relay, fuse, mcb ,start stop switch ,LED indicator and make panel serviceable complete all as specified and directed. Note:- 1. cost of minor spare parts are included in quoted rate to related item.
Comprenesive maintenance and rapair including renewal/replacement of defective parts of all existing fire detection system complete consisting of addressable fire control panel, Remote Terminal Unit panels, smoke/heat detector, response indicator, sounder, Manual call Point, Amlifier, Loud speaker, Loop isolator, Zone monitor module, Modem etc. to make 100 % serviceability of the complete incl checking of fire detector, cleaning of detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of batteries, the alarm function of control and indicating eqpt be checked by the operation of trigger device in each zone as described, the system installed in Fire station every month during first or last week as directed by engineer-in-charge Note:- (i) Cost of new components shall be paid for separately under relevant items of schedule 'A" sec-1 Item No. 42 to 48. (ii) Contractor's rep will visit minimum once in a month to every panel and take serviceability certificate duly signed by the user. Note : "Repair and maintenance of Fire Alarm system should be done through OEM or through the authorized service provider of the OEM or any other agency dealing with the installation and maintenance of FIRE ALARM REMOTE COMMUNICATION SYSTEMS (RTU) and has vast experience in the relevant field as approved by the next higher authority to the Accepting Officer".
Dismantling ,servicing of all multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and directed every three month
Supply only of 6 V, 4.5 AH battery supply for back up to RTU panel each panel as 2 No. Make: Exide/Amar Raja/Amron
Supply only of 12 V, 7 AH battery for back up to all FACP panel. Make: Exide/Amar Raja/Amron
Supply only Indoor type detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric /optical with base with self built intelligence all as specified and as directed.
Supply only electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a)Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A , c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key, d) Ingress Protection IP-43 & Material-ABS Make: GST
Disconnection the LT & Earth Connection of isolation Transformer of capacity 60 KVA and lifting it from its installation place and transportation to civil workshop at Tezpur for repair and transporting back to its existing installation and install at its original foundation complete including connecting the LT & Earth connection of isolation transformer foundation bolts etc including removing old painting by scraping and spray painting with two coats of synthetic enamel paint, writing of SM No/MES No complete all as specified and as directed. NOTE: (1) Spare parts will be mesured and paid seprately under relevant items. (2) Cost of Transformer oil for cleaning by hosing down shall be deemed to be included in the qouted rates. (3) Gasket set ,LT side ceramic bushing spindle for LT Side for replacement shall be measured ans paid seprately under relevant items.
Reinsulation and heat varnishing of LT coil in local workshop by opening of 60 KVA isolation transformer , disconnected of both LT connection to coil, lifting of Core, filtration of oil up to specific dielectric strength of 35 to 40 KV if the strength is not achieved then change the transformer oil, cleaning the transformer oil tank, after that complete assembleing the coils, trnsformer oil, connection of sensor,and HT/LT spindle ,complete all as specified as directed.
Rewinding of isolation transformer 60 KVA capacity by super enameled copper wire as per existing gauge of primary coil with E class insulation varnishing and baking the coil properly fixing on core and making connection to achieve rated voltage and current all as specified and directed by Engr-in-charge.
Supply only supper enameled copper Strip of aproved quality and suitable gauge for LT side of transformer as per the rated KVA requirment of the transformer of 433/360 KV grade complete all as specified and directed.
M/S TRADE CENTRE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .