Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-Finance | ₹8.7 L | L1 | Accepted-Finance L1 Q bid found in order admitted |
| 2 | L2₹9.6 L+₹93,648 (10.8%)Accepted-Finance | ₹9.6 L+₹93,648 (10.8%) | L2 | Accepted-Finance L2 Q bid found in order admitted |
| 3 | L3₹10.2 L+₹1.6 L (18.3%)Accepted-Finance | ₹10.2 L+₹1.6 L (18.3%) | L3 | Accepted-Finance L3 Q bid found in order admitted |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not enlisted with b ii category Not Recommneded |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not enlisted with b ii category Not Recommneded |
| Sl No | Description | Qty | Unit | SRI SAI KRISHNA ENGINEERING WORKS L1 | R AND A ASSOCIATES ENGINEERS CONTRACTORS L2 | PNR CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for taking down the damaged / un serviceable Lighting arresters expulsion type suitable for 11000 volts complete with all fittings,transmission class,discharge capacity 6.5 Kilo Amps
Make: HTSG /JAIPURIA | 1 | per set | 5,850 ₹5,850 | 6,000 ₹6,000 | 3,500 ₹3,500 Lowest |
| 2.00 | Supply and fix single core 2.5 sqmm cable with copper conductor PVC round sheathed (flexible) industrial control for connections from CTs to relay control panel of capacity 11 KV and 433 KV including all necessary connections required, testing of relay after completing for proper functioning complete all as specified and as directed. | 45 | RM | 57.6 ₹2,592 | 50 ₹2,250 Lowest | 80 ₹3,600 |
| 3.00 | M&L for isolating, cutting, removing the existing damaged end termination and S&F outdoor end termination heat shrink outdoor type (Earthed) suitable for HT UG cable XLPE insulated 3 Core 120 to 185 Sqmm 11KV grade including preparation complete all as directed. (Make: REPL/3M/Raychem) | 4 | Each | 3,780 ₹15,120 | 6,500 ₹26,000 | 3,000 ₹12,000 Lowest |
| 4.00 | M&L for isolating, cutting, removing the existing damaged end termination and S&F outdoor end termination heat shrink outdoor type (Earthed) suitable for HT UG cable XLPE insulated 3 Core 240 to 300 Sqmm 11KV grade including preparation complete all as directed. (Make: REPL/3M/Raychem) | 2 | Each | 5,040 ₹10,080 | 12,000 ₹24,000 | 3,500 ₹7,000 Lowest |
| 5.00 | M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable XLPE insulalted 3 core 120 to 185 sqmm 11000V grade including preparation complete all as directed (Make:Raychem/ REPL/ Denson). | 2 | Each | 10,800 ₹21,600 | 10,500 ₹21,000 | 8,000 ₹16,000 Lowest |
| 6.00 | M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable XLPE insulalted 3 core 240 to 400 sqmm 11000V grade including preparation complete all as directed (Make:Raychem/ REPL/ Denson). | 6 | Each | 14,400 ₹86,400 | 16,000 ₹96,000 | 9,000 ₹54,000 Lowest |
| 7.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge. | 25 | Cum | 360 ₹9,000 | 150 ₹3,750 Lowest | 220 ₹5,500 |
| 8.00 | Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge. | 22 | Cum | 153 ₹3,366 | 50 ₹1,100 | 35 ₹770 Lowest |
| 9.00 | Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge. | 3 | Cum | 315 ₹945 | 40 ₹120 Lowest | 45 ₹135 |
| 10.00 | M & L for dry sand cushioning and cover for protection of cable, complete all as specified and as directed by the Engineer-in-Charge. (Note: Approved local tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning and cover). | 6 | Cum | 1,200 ₹7,200 | 800 ₹4,800 | 650 ₹3,900 Lowest |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
30 Jul 2026, 6:00 pmClosed
SHAILENDER
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8678 MAINTENANCE AND REPAIRS/REPLACEMENT OF HT CABLE, ACBs MCCBs, EARTHINGS, APFC PANELS, LT FEEDERS BOXES AND CONNECTED ACCESSORIES AT DRDL KALINGA UNDER AGE (I) RnD NSTL, VISAKHAPATNAM
2026_MES_776000_1
AGE I R AND D NSTL VIZAG 8678
Open Tender
Electrical and Maintenance Works
Item Rate
NSTL VISAKHAPATNAM
Class E
Category b ii
9 documents required · 9 mandatory
₹500
AGE I R n D NSTL, Visakhapatnam
₹19,800
Yes
10 Sept 2026
2 Jul 2026
3 Aug 2026
2 Jul 2026
30 Jul 2026
16 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for taking down the damaged / un serviceable Lighting arresters expulsion type suitable for 11000 volts complete with all fittings,transmission class,discharge capacity 6.5 Kilo Amps
Make: HTSG /JAIPURIA | 1 | per set | - | - |
| 2 | Supply and fix single core 2.5 sqmm cable with copper conductor PVC round sheathed (flexible) industrial control for connections from CTs to relay control panel of capacity 11 KV and 433 KV including all necessary connections required, testing of relay after completing for proper functioning complete all as specified and as directed. | 45 | RM | 1 | ₹45 |
| 3 | M&L for isolating, cutting, removing the existing damaged end termination and S&F outdoor end termination heat shrink outdoor type (Earthed) suitable for HT UG cable XLPE insulated 3 Core 120 to 185 Sqmm 11KV grade including preparation complete all as directed. (Make: REPL/3M/Raychem) | 4 | Each | 2 | ₹8 |
| 4 | M&L for isolating, cutting, removing the existing damaged end termination and S&F outdoor end termination heat shrink outdoor type (Earthed) suitable for HT UG cable XLPE insulated 3 Core 240 to 300 Sqmm 11KV grade including preparation complete all as directed. (Make: REPL/3M/Raychem) | 2 | Each | 3 | ₹6 |
| 5 | M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable XLPE insulalted 3 core 120 to 185 sqmm 11000V grade including preparation complete all as directed (Make:Raychem/ REPL/ Denson). | 2 | Each | 4 | ₹8 |
| 6 | M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable XLPE insulalted 3 core 240 to 400 sqmm 11000V grade including preparation complete all as directed (Make:Raychem/ REPL/ Denson). | 6 | Each | 5 | ₹30 |
| 7 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge. | 25 | Cum | 6 | ₹150 |
| 8 | Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge. | 22 | Cum | 7 | ₹154 |
| 9 | Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge. | 3 | Cum | 8 | ₹24 |
| 10 | M & L for dry sand cushioning and cover for protection of cable, complete all as specified and as directed by the Engineer-in-Charge. (Note: Approved local tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning and cover). | 6 | Cum | 9 | ₹54 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_868970.xls
BOQ • 12.30 MB
TenderDocument.pdf
Tender Documents • 1.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .