Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81,847.50Admitted-Fee/PreQual/Technical/Finance | ₹81,847.50 | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹85,102.50+₹3,255 (3.98%)Admitted-Fee/PreQual/Technical/Finance | ₹85,102.50+₹3,255 (3.98%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹94,447.50+₹12,600 (15.4%)Admitted-Fee/PreQual/Technical/Finance PROP RAM KRUPA ENTERPRISE PLOT NO 4 JANAKPURI SOC BOKHIRA PORBANDAR GUJARAT 360575 | PORBANDAR | GUJARAT | 360575 | ₹94,447.50+₹12,600 (15.4%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹98,227.50+₹16,380 (20.0%)Admitted-Fee/PreQual/Technical/Finance | ₹98,227.50+₹16,380 (20.0%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | SHUKLA ENTERPRISE L2 | RAMKRUPA ENTERPRISES L3 | VYAS AND SONS ENTERPRISE L4 | KGN ENTEERPRISE L1 |
|---|---|---|---|---|---|---|---|
| 1.00Various defects on enggineering equipment. | |||||||
| 2.00 | E-950:Firemain supply valve to EVAC system not holding due to valve spindle stuck, lid and seat deteriorated. Valve to be overhauled and proved for satisfactory operation. (Type-SDNR, Size -80 mm) | 1 | Nos | 12,450 ₹13,072.5 | 13,250 ₹13,912.5 | 13,200 ₹13,860 | 12,000 ₹12,600 Lowest |
| 3.00 | E-965: Air bottle auto drain system not working causes posture accumulated in aft air bottle. The moisture drain valve to be repaired/ serviced and defect to be rectified and proved for satisfactory operation. | 1 | Nos | 8,300 ₹8,715 | 9,300 ₹9,765 | 9,800 ₹10,290 | 8,000 ₹8,400 Lowest |
| 4.00 | E-966:Anchor washing valve at stbd side is not holding pressure and valve wheel freely rotating. Suspect valve spindle sheared off. Defect to be rectified and prove for satisfactory operation. | 1 | Nos | 8,500 ₹8,925 | 9,500 ₹9,975 | 10,200 ₹10,710 | 8,300 ₹8,715 Lowest |
| 5.00 | E-967: DA no 3 (Make Cummins, Model VTA28DM) emergency cooling valve (Type- SDNR Size:-NB-65mm) not holding pressure due to valve seat deteriorated and valve spindle sheared off. Valve to be overhauled and proved for satisfactory operation. | 1 | Nos | 11,650 ₹12,232.5 | 12,850 ₹13,492.5 | 13,800 ₹14,490 | 11,000 ₹11,550 Lowest |
| 6.00 | E-968:Water seepage due to condensation observed in ref plant resulting in deterioration of copper pipelines. Cold lagging is required to be fitted on affected area and lagging cloth of entire system to be renewed. (approx. area 10 sqr ft) | 1 | Nos | 14,900 ₹15,645 | 16,200 ₹17,010 | 16,800 ₹17,640 | 14,500 ₹15,225 Lowest |
| 7.00 | E-969: Fire main valve for emergency cooling of Da no 2 not holding and rotating freely due to spindle and lid deteriorated and valve body cracked (Type- SDNR Size:-NB-65mm). Valve to be renewed and proved for satisfactory operation | 1 | Nos | 12,800 ₹13,440 | 14,300 ₹15,015 | 14,650 ₹15,382.5 | 12,500 ₹13,125 Lowest |
| 8.00 | E-970:Stopping system wire assembly of emergency firemain pump broken due to wear and tear. Wire along with stopping assembly to be renewed as per sample and proved for satisfactory operation. | 1 | Nos | 7,000 ₹7,350 | 8,100 ₹8,505 | 8,200 ₹8,610 | 6,550 ₹6,877.5 Lowest |
| 9.00 | E-988: Sea water leakage observed from fwd engine room eductor inlet valve rotating freely due to spindle and lid deteriorated (Type – Ball valve ,Mat – Brass, Size:- NB-45mm). Valve to be renewed and proved for satisfactory operation. | 1 | Nos | 5,450 ₹5,722.5 | 6,450 ₹6,772.5 | 6,900 ₹7,245 | 5,100 ₹5,355 Lowest |
Tender Value
Refer Docs
Closing Date
31 Jul 2026, 10:00 amClosed
Engineer Officer for commanding officer ICGS Sarht
ICGS SARTHAK, PORBANDAR
engineering defect rectification
2026_ICG_776640_1
344/05/EN/STK/26-27
Limited
Marine Works
Works
ICGS SARTHAK
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
1 Aug 2026
25 Jul 2026
1 Aug 2026
25 Jul 2026
31 Jul 2026
25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Various defects on enggineering equipment. | - | - | - | - |
| 2 | E-950:Firemain supply valve to EVAC system not holding due to valve spindle stuck, lid and seat deteriorated. Valve to be overhauled and proved for satisfactory operation. (Type-SDNR, Size -80 mm) | 1 | Nos | - | - |
| 3 | E-965: Air bottle auto drain system not working causes posture accumulated in aft air bottle. The moisture drain valve to be repaired/ serviced and defect to be rectified and proved for satisfactory operation. | 1 | Nos | - | - |
| 4 | E-966:Anchor washing valve at stbd side is not holding pressure and valve wheel freely rotating. Suspect valve spindle sheared off. Defect to be rectified and prove for satisfactory operation. | 1 | Nos | - | - |
| 5 | E-967: DA no 3 (Make Cummins, Model VTA28DM) emergency cooling valve (Type- SDNR Size:-NB-65mm) not holding pressure due to valve seat deteriorated and valve spindle sheared off. Valve to be overhauled and proved for satisfactory operation. | 1 | Nos | - | - |
| 6 | E-968:Water seepage due to condensation observed in ref plant resulting in deterioration of copper pipelines. Cold lagging is required to be fitted on affected area and lagging cloth of entire system to be renewed. (approx. area 10 sqr ft) | 1 | Nos | - | - |
| 7 | E-969: Fire main valve for emergency cooling of Da no 2 not holding and rotating freely due to spindle and lid deteriorated and valve body cracked (Type- SDNR Size:-NB-65mm). Valve to be renewed and proved for satisfactory operation | 1 | Nos | - | - |
| 8 | E-970:Stopping system wire assembly of emergency firemain pump broken due to wear and tear. Wire along with stopping assembly to be renewed as per sample and proved for satisfactory operation. | 1 | Nos | - | - |
| 9 | E-988: Sea water leakage observed from fwd engine room eductor inlet valve rotating freely due to spindle and lid deteriorated (Type – Ball valve ,Mat – Brass, Size:- NB-45mm). Valve to be renewed and proved for satisfactory operation. | 1 | Nos | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_874603.xls
BOQ • 0.31 MB
RFP.pdf
Tender Documents • 2.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .