DGM (P AND P)
Projects and Planning PD Admin Building FACT Ltd Udyogamandal Complex Kochi - 683501.
Repair of Water Wall Tubes of Soda Ash Recovery Boiler (KHI) with supply of tubes etc. in Petrochemical Plants-UC.
2020_FACT_546412_1
05061/2019-2020/E21124
Open Tender
Miscellaneous Works
Item Rate
70 days
FACT UDYOGAMANDAL
As per Tender Documents
8 documents required · 8 mandatory
₹300
Yes
FACT LTD
₹1 L
Yes
14 Mar 2020
20 Feb 2020
7 Mar 2020
20 Feb 2020
6 Mar 2020
20 Feb 2020
Amount
Repair of Water Wall Tubes in KHI Boiler
Supply of Boiler Water Wall Tubes of size 76.2 MM OD with thickness 3.5 to 3.7 MM, IBR certified, ASTM SA 192 SEAMLESS, or equivalent or superior material as approved by M/s.FACT Ltd. along with relevant certificates, at FACT Udyogamandal. The tubes shall conform to the specification. Tubes shall be supplied in random lengths of 4.00 to 8.00 Mtrs long without joints.
Complete execution of replacement of defective lengths of the Water Wall tubes, of size 76.2 MM OD and thickness min. 3.5mm to max. 3.7 MM, at specified locations in KHI Boiler which include:- (a) Obtaining necessary IBR approvals / clearance etc. at all stages like Preparation of documents / repair procedure and getting concurrence from F&B for carrying out repair work, as directed by F&B/FACT and as per relevant drawings and also the FINAL approval after completion of work.[FACT scope with regard to IBR approval shall be limited to forwarding of applications and payment of prescribed fees]. (b) Cutting the defective length of tubes with fins at various locations in Boiler. (c) Fabrication of suitable tube pieces with FINs. (d) Edge preparation of existing tube ends, fit-up of pre-fabricated new tube pieces in appropriate positions and welding by TIG with 100% radiography of weld joints of tubes. Filler wire used for TIG welding shall be ER70 S2. Inert gas shall be ARGON Payment shall be made for INCH DIA of completed WELD JOINTS
Fabrication of fins of suitable length and width from 6/8 mm Plates,Welding of fins to tubes by TIG process ,fin to fin joints by TIG/SMAW process. Welding shall be done from inside and outside to avoid flue gas leakage. Payment by FACT for this schedule item will be in Meter Length of TUBE pieces replaced.
Dismantling and refixing the windbox with FO/HR/PILOT Burner units on both sides - NORTH & SOUTH- of Boiler for accessing the wall tubes and boxing up after tube repair work, including cutting and welding, if required.
Carrying out Hydrotest of the boiler after completing the repair.
Scaffolding inside the furnace, using suitable scaffolding material for the safe execution of work, including its supply,erection and dismantling.
Providing safe working Platforms with 0.30 Mtr width x 3.00 Mtr long (approx.) of suitable material.Required material shall be brought by contractor.
DIPAK CONSTRUCTIONS
HIND ERECTORS
MBM ENGG WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .