Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.9 LAccepted-AOC BOULAPASA KAILASHAHAR UNAKOTI TRIPURA PIN 799277 | KAILASHAHAR | UNAKOTI | TRIPURA | 799277 | L1 | Accepted-AOC L1 |
Tender Value
₹66.2 L
EMD Value
₹1.3 L
Closing Date
27 Dec 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy General Manager, ED-Amarpur, TSECL
Deputy General Manager, ED-Amarpur, TSECL
providing service connection to DTW schemes
2022_POWER_35586_1
DGM/ED-AMP/2022-23/15
Open Tender
Electrical Works
Works
180 days
ED-Amarpur, TSECL
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Yes
₹1.3 L
Yes
20 Feb 2023
21 Dec 2022
28 Dec 2022
21 Dec 2022
27 Dec 2022
21 Dec 2022
21 Dec 2022 - 27 Dec 2022
Amount
Supply
8 mtr. Long PCC Pole
9 mtr. Long PCC Pole
9 mtr. Long steel Pole
Painted Stay set complete HT 20sq. Mm
Painted Stay set complete LT 16sq. Mm
Stay wire 7/2.50 sqmm
11 KV Stay/Guy insulator (Porcelin)
LT Stay/Guy insulator (Porcelin)
Stay clamp
Strain Screw
LT Shackle insulator
LT Straps And bolts
MS Channel (100 x 100x50x 6 mm )
MSl Channel ( 75 x 40x40x 6 mm )
MS Angle ( 65x 65x 6 mm)
Nut & bolts 16X50 mm
Nut & bolts 16X75 mm
Nut & bolts 12X250 mm
Nut & bolts 12X300 mm
Nut & bolts 12X90 mm
11 KV GOS(three phase Polymeric type)
11 KV DOF (three phase Polymeric type)
11KV L.A (Polymeric 9KV, 5KA)
11KV Polymeric composite 45KN Disc Insulator
11KV Disc fittings(6/1/2.59 & 6/1/3.35)
11KV 320 mm CD polymer composite PIN iNsulator
ACSR Weasel(30.00Sq. Mm) Conductor
8 SWG G.I Wire
11KV Danger plate
LT Danger plate
MS Clamp Assorted size of MS Flat(50x60mm)
Rewireable porceliene Cut-Out 200Amps
PVC Single Core 16mm Sq.
Bimetalic Lugs(70 Sq. mm)
PVC Single Core 70mm Sq.
PVC pipe 1/2 inc. Dia
Supply of 2.5 mtr. Long 40mm Dia GI pipe (Make TATA/Jindal)
Supply of 60 KG Salt & 55 kG Charcoal(for 1 pit)
Supply of MS Nuts & Bolts in/c washer of Assorted size ISI Mark Machine Made(for Earthing)
Reel Insulator
Erection
8 mtr. Long PCC Pole at any kind of soil upto a depth of 1/6th of pole height in/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading
9 mtr. Long PCC Pole at any kind of soil upto a depth of 1/6th of pole height in/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading
9 mtr. Long steel Pole at any kind of soil upto a depth of 1/6th of pole height in/c excavation, refilling the pit with soil up to the ground level , ramming & making complete in all respect i/c hand cart carriage & manual carriage with necessary loading & unloading etc as reqd.( ST Pole 9 mtr long (SP 30)
Painted stay set complete direct in earth with 19 mm dia 1.8 mtr long painted stay rod ,anchor plate of size 300x300x8 mm ,thimble, turn buckle ,7/3.15 mm dia GI stranded wire & stain insulator insulator etc in/c supply of MS Clamp,Nut & Bolts etc asa reqd. & making complete in all respectas (GI Stay set HT 20 sq mm)
Painted Stay set complete direct in earth with 19 mm dia 1.8 mtr long painted stay rod ,anchor plate of size 300x300x8 mm ,thimble, turn buckle ,7/3.15 mm dia GI stranded wire & stain insulator insulator etc in/c supply of MS Clamp,Nut & Bolts etc asa reqd. & making complete in all respectas (GI Stay set LT 16 sq mm)
Shackle insulator of size 75mm x 90mm/100mm x 15mm with straps & bolts/ U clamp on poles (excluding the cost of straps U clamp, Nuts & Bolts) LT Shackle Insulator (3x3.5 )"
0.8 mtr long MS Channel (100 x 100x50x 6 mm ) for sub stn. etc
2.8 mtr long MS Channel (100 x 100x50x 6 mm ) for sub stn. etc
2.8 mtr long MS Channel ( 75 x 40x40x 6 mm )for sub stn. GO,DO fixing bkt. Etc
MS Channel ( 75 x 40x40x 6 mm ) 0.3 mtr long for single pole top cross arm
MS Channel ( 75 x 40x40x 6 mm ) 1.2 mtr long for single pole bottam cross arm
MS Channel ( 75 x 40x40x 6 mm ) 2.2 mtr long for single pole bottam cross arm
MS Angle ( 65x 65x 6 mm) 1.5 mtr long SP Guarding cross arm
MS Angle ( 65x 65x 6 mm) 2.8 mtr long DP Guarding cross arm
MS Angle ( 65x 65x 6 mm) 2.5 mtr long DP cross arm
Three phase 5-wire C-type Bracket( MS Angle 65x 65x 6 mm)
11 KV 200 Amp GOS unit set of three nos inc. necessary connection complete as per technical specification (Excluding the cost of back clamp, nuts & bolts) 11 KV G.O.S (three phase)(Polymeric type)
11 KV DOF unit set of three nos inc. necessary connection complete as per technical specification (Excluding the cost of back clamp, nuts & bolts) 11 KV D O F (three phase)(Polymeric type)
9 KV, 5 KA single pole metel oxide gapless type LA, inc. necessary connection complete as per technical specification .11 KV Polymeric LA,9 KV,5KA
11 KV disc insulator with fittings, nuts & bolts, washers etc. as reqd. as per direction of Engineer-in-charge. (11 KV Polymer composite 45 KN Disc Insulator)
11 KV 320 mm CD Polymer composite PIN Insulator
Laying & stringing of ACSR weasel (30 mm ) cable in/c hoisting & binding etc. complete as required
Laying & stringing of 8 SWG Gi wire in/c hoisting & binding etc. complete as required
Insttalation/ Positioning of 11/0.430 KV , 3 phase 63 KVA distribution transformer on pole with necessary connections & fitting & fixing of all allied assessories , components as redq. For making complete in all respect for energizing
Fitting & Fixing11KV Danger plate
Fitting & Fixing LT Danger plate
Earthing with GI pipe 2.5 mtr Long and 40 mm dia, inc. excavation, refilling with alternate layer of salt & charcoal as per drawing (excluding supply of GI wire, nuts & bolts, etc. as required)
Providing three phase Service Connection with laying PVC Cable from nearby electrical Pole to premises upto 35 mtrs in length supported by GI wire Reel insulators i/c fitting fixing of energy meter as required.
Erection of protective guarding / cross lacing for 415/240 volt line by GI wire 98/10 SWG as per technical specificationacross road/river/telecom line etc.in horizontal/verticle formation complete with spool/Reel insulator
Carriage of 11/0.43 three phase 63 KVA Transformer by mechanical transport from A.D Nagar Store Yard, Agartala to Work site Vis-à-vis including unloading and placing on pole mounted structure as required
Providing Sub-Station protective fencing by 75 x25 mesh of 2.5x3.5 mtr.and height of 1.5 mtr. As per Engineering recruitment by 01 nos. MS Angle post (50x50x6mm) of height 2.0mtr .Horizontal Bar 6x3.5 mtr and 6x2.5 mtr and vertical Bar 10x1.5 mtr of MS flat (35x6mm) and single part of MS Grildoor of size L-1.5 / B-1.2 mtr with locking arrangement including necessary grouding and painting by Aluminium paint over red oxide priming of approved quality as reqd . as per TS including supply of all materials (MS Angle will be supplied by the Deptt)
Grouting of steel tubular poles with CC of ratio 1 :2:4 (1 cement: 2 river sand: 4 jhama brick aggregate of 20 mm. nominal size) ilc supply of cement, sand and brick aggregate complete with excavation, refilling of earth, ramming alongwith centering and shutterirtg as required.(@ 0.273 Cum per steel tubular pole as per TSECL specification ).
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .