Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC 93 BAPUJI NAGAR ITC ROAD SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹43.0 L+₹8.2 L (23.6%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Firm not having appropriate category, MRO not submitted |
Tender Value
₹39.3 L
EMD Value
₹78,700
Closing Date
20 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
PROVN OF CERTAIN MAJOR REVENUE AND MINOR WORKS AT AF STN SARSAWA AND 1AFSB DEHRADUN UNDER GE (AF) SARSAWA
2023_MES_613488_2
8123/SAR-41/2023-24
Open Tender
Civil Works
Item Rate
333 days
GE (AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) SARSAWA
₹78,700
Yes
4 Jan 2024
29 Sept 2023
27 Oct 2023
29 Sept 2023
20 Oct 2023
6 Oct 2023
29 Sept 2023 - 6 Oct 2023
Amount
Excavation in post holes each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplush soil to a distance n exc 50m and making good surface complete all as directed by Engineer-in-charge and all as specified.
M&L for PCC Type C2 1:3:6 (40 mm graded aggregate) Cement concrete in foundations, filling and mass-concrete complete all as specified & directed by Engr-in-Charge.
M&L steel work in tubular truess, purline rafter columns etc including welding ,butt welded tubes conferming to IS-1161-1979 grade St-240, complete all as directed by Engineer-in-charge.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed by Engineer-in-charge and all as specified.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying one coat of red oxide primer complete all as directed by Engineer-in-charge and all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverin/cladding t wall fixed with self tapping screwas as specified fixed etc complete all as specified & directed by Engr-in-Charge.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 Gde E-165 etc complete all as specified & directed by Engr-in-Charge.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out in soft loose soil.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in soft/loose soil.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified& directed by Engr-in-Charge.
M&L for 100 mm thick PCC 1:4:8 type D -2 using 40 mm graded aggregate as in sub base of path/hardstanding complete all as specified & directed by Engr-in-Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed by Engr-in-Charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
M&L Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe-410 -W (Gde-E- 250) quality-A) all as specified and directed by Engr-in Charge.
S&F 4mm dia galvanised steel wire, 25x25 mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling all as specified & directed by Engr-in-Charge.
M&L for 100 mm thick PCC 1:2:4 type B -1 using 20 mm graded aggregate, finishing cement concrete surface even & smooth without using extra cement complete all as specified & directed by Engr-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
Dismantling timber scantlings 40 sq. cm and over in section, in any position unframed work complete all as specified
S& F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations or plain sheet side lap fixed with coach screw and washer in roof, wall etc complete all as specified
Demolition of cement concrete (un-renforced) in ground floor and paving. exc. 15 cm thickness (below or above ground level.) & removal of rubbish material complete all as directed by Engineer-in-charge and all as specified.
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate), as in sub base all as directed by Engineer-in-charge.
M&L Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Taking down Chowkatts or frames with shutters ( without taking off shutters from the frame exc 1.5 sq. m but n exc 4 sq m each and refixing in same opening.
M&L for Reinforced cement concrete (nominal mix) in Type B1 1:2:4 (20 mm graded stone aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; , Rough finished surfaces of concretec flat complete all as specified and directed by Engr-in-Charge.
M&L Mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to TMT bar complete all as specified and directed by Engr-in-Charge.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified & directed by Engr-in-Charge.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Supply, install, test and commissioning of non -clog sewage submersible pump set 1-phase 2 HP, Discharge: 600-100LPM at 2.8 to 14 mtr head complete with float switch for automatic operation all as per model no. STPM22(1PH)-14, Make : CG
Supply, install, test and commissioning of electric panel wall mounted made out of 2mm thick CRCA sheet and comprising of 4-pole copper bus bar of rating 40Amp, MCB TPN 40Amp, 10KA rating-01No as incomer, MCB SPN 16Amp, 10KA rating-03Nos as outgoing complete with internal wiring.
Supply, install test and commissioning of PVC insulated and FR PVC round sheathed copper conductor (flexible) industrial cable 1100V grade confirming to IS 694 of size 4 Sqmm 2-core drawn through and including PVC rigid conduit 20mm dia fixed to wall with saddles etc
Supply and fixing HDPE pipe of pressure rating 6Kgf/sqcm 50mm bore complete fixed to wall or in trench etc
Supply and fix electric water heater, storage type outer body made out of ABS & PP, heating element of 2 KW storage capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, SS connection pipe, temperature control knob etc complete all as specified and as directed by Engr-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep 1400 RPM Double bearing with, blades, and frame and louver complete with making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed by Engr-in-Charge
M&L for fixing PVC gang box for mounting one switch of 5 Amps including all accessoriese complete all as specifies and directed.
S & F of circuit wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 1.5 sqmm (Nominal area) drawn in and including concealed PVC conduit of suitable size as directed with and including one run of 1.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 1.5 sqmm cable and one run of 1.5 sqmm cable of earth continuity conductor and conduit shall be a unit length.
All as per item no 37 above but for 4.0 Sqmm wire
S&F switch piano type 5 amp one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply and fix steel body desert cooler electric driven single phase having 18" exhaust fan motor with nominal air flow capacity of 5000 CuM per hour including submersible water pump heavy duty with water storage capacity upto 140 Ltrs with wood wool pads 03 sides over flow pipe drain pipe water filling point with automatic float valve cooler body made of powder coated metal sheet suitable thickness approved by Engr-in-charge complete all as specified and directed. Make- Khaitan/Crompton or equivalent
Supply & Laying, Jointing Galvanized steel water tubing, medium grade of 15 mm bore, screwed and socketed joints with and including all required fittings as on walls etc complete all as directed.
M&L for cutting GI pipes upto 40 mm Dia for insertion of new tees,branches connecton for new branch including any tee and necessary accessories complete all as specified and directed.
Supply and fixing Chromium plated Bib taps 15 mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed required all as specified and directed.
S&F Stop valves Chromium plated 15 mm bore cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F in MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket with MCB 20 Amps capacity suitably fixed in a weather proof metal enclosure complete all as specified and directed by the Engr-in-charge.
M&L for point wiring with 1.5 Sq mm nominal area PVC insulated and unsheathed cable single core FRLS copper cable 1100 Volts with multistranded, copper conductor in and including PVC rigid concealed conduit (heavy grade) including chases cutting as required on site and conduit accessories along with continous earth wire 1.5 sqmm PVC insulated and unsheathed single core FRLS cable 1100 Volts grade with Multistanded copper conductor and connected to common earth dolly, with and including cadmium plated sunk Modular metal flush boxes for modular switches complete all as specified and directed, One celling / Exhaust fan point controlled by one switch one way . Note:- modular white cover and plate with frame will be measured and paid saperately under respective item Note:-Item No. 47 to 59 shall be executed at 1AFSB Dehradun.
S&F modular switch 1 way 6 amps 1 module all as specified and directed.
Supply & fixing white modular cover plate with frame for fixing of modular switches of following :- (i) 2 module
Ditto but 3 module
S& F blank speacer plate for single module all as specified and directed.
M&L for sub-main wiring with two single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm 1100 volts grade and including PVC casing and caping with all fitting and fixing accessories and including PVC insulated unsheathed, multistranded copper conductor cable of size 2.5 sqmm for earth continuity conductor and including making good the disturbed surfaces complete all as specified and directed.
S & F in repair MCB distribution board single pole and neutral 4 way double door factory made sheet steel, phosphates, powder coated with 200 Amps rated bas bar, 240 volts, neutral link, earth bar and Din rail double door and making good disturbed surfaces of walls, floors, etc. complete all as specified.
Supply and fix Isolator SPN 32 Amps 'C' series 240 Volts complete all as specified and directed.
Supply and fix MCB SP 6-32 Amps cpacity 'C' series 10 KA ratings complete all as specified and directed.
Supply & fix exhaust fans AC single phase 230/240 V of size 300 mm sweep with louvers complete all as specified and directed.
-ditto- but 380 mm sweep complete all as specified and directed.
M & L for cutting cement concrete wall to the shape as per the exhaust fan in circular shape including required PCC and making good the disturbed surface all as specified and required at site complete.
Supply & fixing stainless steel kitchen plate rack of size 900 X 750 X 230 mm of best quality complete all as specified and as directed.
M & L for point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan point controlled by one way switch
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed Note :- (a) All fittings shall be ISI marked and shall have approval of CMRI Dhanbad .(b) Original Test certificate of Manufacturer shall be produced by Contractor .
S&F Flame proof exhaust fan 300 mm sweep single phase including frame motor blade and all asseseries and making of hole in brick work, wooden/Aluminium window complete all as specified and directed. Make- Sudhir, Crompton, Shyam
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia on surface/wall/ceiling including all flame proof conduct fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 1.5 Sqmm and connected to earth dolly complete all as specified and directed by Engrs-in-Charge.
Supply and fixing flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc all as specified and directed. Make- Sudhir/Shyam/Flexpro
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 8 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate. Make-Havells/Indoasian/Legrand,
S&F MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core including lugs of suitable size all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core including lugs of suitable size all as specified and directed.
Supply and erect true vertical steel tubular swaged pole confirming to IS-2713 part-II 410 SP-31 ,9.0 meter long complete with MS base plate of 6 mm thick of size 300x300 mm , finial taper plug, cap , bolt, nuts, eashers including painting externally with two coats of aluminium paint over a coat of red oxide primer for exposed portion and two coats of black bituminious paint for embeded portion in concrete as well as throughout internally including povision of white and blue colour strips with fluorescent paint upto 1.5 mtr height and numbering of pole complete all as specified and directes by engr-in-charge.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection with 4KV driver builtin sugre protection & additional 10KV surge protection device, system lumens 3500 lm, THD≤10%, efficacy not less than 100 lm/watt, Colour temp 5700 K , CRI ≥ 70, Prower Factor ≥0.95 complete and impact resistance IK07 f complete all as specified and directed by engr-in-charge.
M&L street light bracket made out from GI Pipe 32 mm bore, light grade, 1.2 m long bent to shape including fixing 02 set of clamp made out from MS Flats of size 25x5 mm complete with nuts and bolts and washers of suitable size duly painted with two coats of aluminium paint over a coat of red oxide primer all as specified and directed .
S&F non metallic junction box made out of thermoplastic of size 250x250x160 mm for street light poles with connector for connection incoming and outgoing cables including provn of 01 No MCB SP 2 Amp to control the pole light circuit including 4 nos aluminium bus bars mounting on the insulator and fixing clamp made of FI 25x3 mm with back strip with suitable nut, bolts and washers including suitable size of double compression cable glands for incoming and outgoing cables complete all as specified and directed.
S & F PVC insulated copper wire 2.5 sqmm 3 core for street light fitting from juction box to fitting in and including heavy duty PVC conduit comple along with suitable clamps all as specified and directed.
Supply and fixing Earthing to DBs with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
Ditto but with GI strip 25x4 as earth lead
Supply and fixing LED type flood light 100 watt 230 watt volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
S & F of metallic frame duly welded for hanging flood lights including nuts, bolts, washers,clamp in any shape or size as directed including one coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
S&F of timer switch for security light duly steel enclosed with locking arrangement fixed to wall/pole / existing panel by means of clamp.nut,bolt washers or by welding including following items-(a) MCCB 63 A 16 KA 4 Pole-01 Nos,(b) MCB SPN 16-40 Amp - 01 Nos, (c) Power Contactor ML3 , 3 Pole- 01 No, (d) Time switch analog dial type - 01 Nos, (e) Bypass arrangement for testing/repair of light.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 25 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
S&F 20 KVA isolation transformer Outdoor type three phase 50 Hz , Copper wound , oil cooled , class of insulation B ,metallic body duly powder coated designed for input Voltage range 415 volt ±5% and output voltage 415 volt ±5%,Ratio 1:1 , vector group Dyn 11, Delta-star outdoor type IP 55, with first filling of transformer oil of requisite dielectric strngth up to level efficiency more than 95 % , separate neutral bushing shall be brought out for earthing Potential difference between neutral to earth less the one volt with all standard fittings like digital temperature meter , adequate number of cooling radiators , lifting hooks one set , Earthing terminal complete with Over load /short circuit protection complete all as specified and directed.
Returning, filling in including spresding leveling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge..
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for copings of poles/stay/panels complete all as specified and directed.
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables complete all as specified and directed..
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & as directed.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified & as directed.
M & L for providing cement concrete type B1 1:2:4 (20 mm graded aggregates as in lintels Cum upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified & directed.
Excavation in trenches n.exc. 1.5 m wide and n.exc.1.5m in depth for laying of XLPE insulated Cable including getting out all as specified & directed by Engr-in-Charge Note:-Item No. 90 to 98 shall be executed at 1AFSB Dehradun.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc 1.5 m above starting point.
M&L for spreading & leveling dry clean Ganga sand in trenches for cushioning UG cable complete all as specified and directed.
M&L for sub class old size of Brick in trenches for cable protection of LT Cables complete all as specified and directed.
S&F of 80 mm nominal bore light grade galvanised mild steel tubing with all fittings and fixed to poles / walls with mild steel clamps, bolts, nuts and washers complete all as spefified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core all as specified and directed. Make : Havells/Polycab/Gloster
Material & Labour for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip of 32x6mm (up to 7.5m in length from earth plate) by means of bolts and nuts, check nuts and washers of galvanized iron or steel all as specified and shown in Electrical Plate No 3 of SSR part 1 (2009) including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel and 40mm dia light grade for protection of earth electrode, 20mm dia for watering and tested on completion complete all as speicified and as directed .
Supply, install, testing and commissioning of Eco friendly Generating Set Diesel Engine driven of capacity 62.5 KVA/50 KW at 0.8 PF or nearest higher size 415 volts AC, 3 phase, 50 Hz 4 wire, directly coupled alternator and engine, water cooled, common base platform with inbuilt fuel tank and including all excavation, PCC foundation, anti vibration pads/dampers as per manufacturer instructions and as directed by manufacturer, DG set to work at ambient conditions and produce specified out put, the derating factors, if any, to be taken into consideration while arriving the capacity to give specified out put, DG set to be factory assembled by the OEM of the engine manufacturer and all components to be accommodated in enclosure and other accessories comprising of the following:- (A) Engine : Eco-friendly emmission limits for diesel engine as per CPCB documents vide latest notificaton GSR 105(E) dated 17 Feb 2015 at Ser No 95 issued by Ministry and Forest, Govt of India and noise level (CPCB norm compliances) diesel engine confirming to BS/IS standard,confirming to BS:5514/DN-6271 / IS 10002/ISO-3046, BHP as per the standard design of OEM to run the DG set in full load / 110% overload with out any change of out put parameters, (not less than 90 BHP),1500 RPM, water cooled complete under NTP condition, with a provision for 10% over load for one hour on 12 hours continious running with the following:- (i) Radiator/Heat exhanger cooling system (ii) Corrosion inhibitor coolent (iii) Engine mounted water pump (iv) Thermostats (v) Fly wheel with housing complete (vi) Fuel pump system with heavy duty injectors and self contained piping (vii) Spin on type fuel filters (viii) Lub oil pump with self contained piping (ix) Heavy duty Turbo Charger (x) Air intake manifold with necessary connections (xi) Dry type replaceable paper element air filter (xii) Exhaust manifold with flexible piping system and exhaust chimney extended up to a height as per statutory requirement of local pollution control board. The nearest building is 16 RM with G+1 configuration.(xiii) Hospital grade silencer (xiv) BLANK (xv) Self starter, 12 V, DC (xvi) BLANK (xvii) Lead acid DC battery 12 volts,88AH - 01 Nos (xviii) BLANK (xix) BLANK (xx) Electronic / Digital / Manual governor as per manufacturer design and specification.(B) Alternator : Synchronious alternator 62.5 KVA, 1500 RPM, 415 Volts, 50 Hz, 3 phase system self excited, self regulated, self ventilated in brushless design provided with suitable automatic voltage regulator with ± 1% all load between no load to full load and power factor 0.8 to unity with 10% overload capacity for one hour in any 12 hours of operation without exceeding temp rise limit, confirming to BS:5000/IS 4722, IS 13364 and IEC 60034-1 with standard design with IP 23 protection and class "H" insulation & having surge seperator for protection of alternator for reverse supply. The alternator shall be capable of carrying an unbalanced load of 25% without injurious heating of any part, provided rated current is not exceeded. The alternator shall withstand a short circuit at its terminals for three seconds with excitation adjusted to develop rated voltage at noload without any damage.(C) Base Frame : Base rail made out of suitable MS channel mounted on AVM pads as recommended by the manufacturer with integral fuel tank of suitable capacity with drain plug, air vent, inlet and outlet connection, level indicator and with provision of cleaning.(D) Acoustic enclosure : Acoustic enclosure drip proof & screen protected meeting stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75% load under free field conditions with air inlet louvers powder coated. Use of stainless steel hardware and insulating materials shall meet exacting IS : 8183 insulating materials. Acoustic enclosure shall be as per manufacturer"s design. Two point lifting shall be provided for easy handling.(E) Provision of DG set foundation : As recommended by the manufacturer in PCC 1:2:4 up to 30cm above ground level.(F) Generator controller: Microprocessor based generator controller with 4 line LCD display with settable prameters for display, audio visual warning and shut down for the following parameters:-(i) Display parameters - Battery voltage,Coolent
Temperature,Lubricating Oil Pressure, Engine Speed, Engine Hours,Fuel level indication in %,Generator voltage, current, PF, KWH & KW (ii) Audio visual warning for following - Low oil pressure, High coolant temperature, low battery voltage, low fuel level (iii) shut down/trip with audio/ visual anunciation for the following parameters - High water Temperature (HWT), Low lube oil pressure (LLOP),Over/under speed,high canopy temperature, under/ over voltage, under/over frequency, low fuel level.(G) Outdoor type AMF panel : AMF Panel shall be indoor type made out of 3 mm thick CRCA sheet powder coated and consists of the following :-(i) AMF relay, microprocessor monitoring and control system with LED Display and LED's for annunciation of parameters of control panel and with four entering fault inputs. (ii) Bus bar of aluminium strip of 200 Amps - 04 Nos for phase & neutral duly mounted on SMC/DMC insulators of suitable length. (iii) Contactor, 3Ph, 415V, AC3 rating of capacity 160A, for both main & DG supply. (iv) Contactor, 3Ph, 415V, AC3 rating of capacity 80A, for both main & DG supply. (for neutral) (v) MCCB, 4 pole, 160 A, 25 KA rating with fixed thermal and magnetic setting having lcs = 100% lcu - for both main & DG supply. (vi) Auxiliary contactors 4 Nos (vii) Multifunction meter for measure of voltage, current, frequency, KWH, PF, KVRH and KVAH including provision of CT's of suitable capacity connected to outgoing 12V battery. (viii) SMPS battery charger suitable for charging feeder. (ix) Micro-processor control, self operated over current and earth fault relay with instantaneous setting including CT's of class 5P10 of 160/5A capacity connected on outgoing feeder. (x) PVC insulated armoured, multicore, copper conductor cable for connection of DG set to AMF panel. (xi) Control wiring PVC insulated, copper conductor of 1.5 Sqmm inside AMF panel. (xii) LED based indication lamps for DG supply and main supply.(xiii) Engine protection : Low lub oil pressure, high/low coolent temp, battery over/ under/ weak volts, fail to cranks/ start, sensor failure, crancking lockour, low fuel level. (xiv) Data logging: Engine hrs, control hrs and upto 5 recent fault codes (xv) PVC insulated copper conductor multicore control cable of adequate size from AMF panel to diesel engine and elsewhere. (xvi) Configurable glow plug control. (xvii) 12/24 volts DC operation. (xviii) Sleep mode (xix) Modbus interface. (xx) Inpower compitable (PC based service tools) Certifications: Meets the requirement of relevent ISO, EN, mili std and CE std. Hospital grade silencer with rain cap suitable optimise to meet stringent noise emmission laid down by MOEF/ CPCB. (xxi) 4-20 mA analog input compitable for oil pressure sensor and fuel level sensor. (xviii) Maintenance due alarm base on engine run time and due date. (xxii) Exercisor scheduler. (xxiii) Micro processr control self operated over current and earth fault relay with instanteneous setting including CTs of class 5P10 of suitable capacity for protection and metering complete all as specified.
SUBHASH CHAND CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .