Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹11.9 L+₹44,055 (3.84%)Rejected-Finance 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Being not fulfill the PQ criteria |
Tender Value
₹14.9 L
EMD Value
₹29,900
Closing Date
25 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Clement Town
GE Clement Town MES Dehradun
REPAIR AND REPLACEMENT OF COOLING / HEATING APPLIANCES AT NHO UNDER GE CLEMENT TOWN, DEHRADUN
2020_MES_399765_1
GE/CLT/ Of 2020-21
Open Tender
Civil Works
Item Rate
210 days
GE Clement Town
Class E Cat b(i)/c(i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹29,900
Yes
5 Mar 2021
31 Dec 2020
27 Jan 2021
1 Jan 2021
25 Jan 2021
11 Jan 2021
60 days
Amount
M&L for servicing window/split/cassette type AC 1.5/2 TR including cleaning, replacement of and removing dust by air blower and washing with reuired solution and dressing electrical connenctions complete all as specified and directed.
Taking down unservceable 4 way reverseable cycle valve (Heating and cooling) of any make any type AC 1.5/2 TR capacity and S&F new valve including cutting copper tube providing additional copper tube of existing size and breezing making leakage proof and testing copper function on load complete all as specified and directed.( Note :- Gas charging will be paid separtely.)
M&L for replacement of thermostate switch suitable for 2 TR capacity of window /Spllit type AC of capacity complete all as specified and directed.
M&L for replacement of starting relay box type suitable for 2 TR capacity of window type AC of capacity complete all as specified and directed.
M&L for replacement of starting capacitor of capacity of 100-120 mfd For split/Window type AC 1.5/2TR complete all as specified and directed.
M&L for replacement of running capacitor of capacity of 36 mfd For split/Window type AC 1.5 TR complete all as specified and directed.
M&L for replacement of running capacitor of capacity of 45 mfd for split/ Window type AC 2 TR complete all as specified and directed.
Taking down blower fan motor of window/ Split type AC 1.5 TR / 2 TR capacity carefully complete all as specified and directed.
S&F in replacement 230 V SP contactor 30 Amps for split/Window type AC 1.5 TR / 2 TR capacity complete all as specified and directed.
Taking down unserviceable compressor unit complete and sealing capillary carefully from window/Split type AC of capacity 1.5 TR / 2 TR complete all as specified and directed.
M&L for charging of refrigerant gas M 22 for window & Split AC 1.5 TR/2 TR capacity including leakage, testing and repairing for leakage complete all as specified and directed.
M&L for charging of refrigerant gas R-134 (a) including leakage, testing and repairing for leakage complete all as specified and directed.
M&L for rewinding of electric blower fan motor of window/Split type AC 2 TR capacity with super enameled copper winding wire of same guage as original and re-fixing the same in the position complete all as specified and directed.
S&F blower / condensing AC electric motor SP 220/230 V suitable for Split / window type AC 1.5 TR / 2 TR capacity complete all as specified and directed.
S&F condensing motor fan blade for window type / Split type AC 1.5 TR / 2 TR capacity complete all as specified and directed.
Disconnecting ,dismantling of extg split type AC 1.5 /2 TR & refixing the same at new location complete all as specified and directed.
Disconnecting ,dismantling of extg window type AC 1.5 /2 TR & refixing the same at new location complete all as specified and directed.
S&F copper pipe with insulation of size 1/4" for Split AC complete all as specified and directed.
All as per item No. 18 above but size , 5/8" and -ditto-
M & L for replacement of MCB Protected socket PVC Plastic base Model (White) 2 Pin & Earth plug socket 20 Amps single phase with top & rating of MCB C 25 Amps in existing box & connecting up complete all as specified and directed.
M&L for replacement of new Print circuit board (PCB) suitable for Window/Split AC including all connection and testing complete all as specified and directed.
M&L for replacement of new compressor rotary type suitable for 1.5 TR Window/Split AC complete all as specified and directed.
All as per item No. 22 above but 2 TR and -ditto-
S&F of Remote sensor kit for Split type AC capacity 1.5/2 TR capacity complete all as specified and directed.
M&L for taking down and replacement of sealed type compressor unit company repaired suitable for 80/100 ltr cooling capacity water cooler fixing in position ,testing of leakage making necessary connection and testing complete all as specified and directed.
All as per item No. 25 above but 60/80 Ltr cap and -ditto-
M&L for replacement of starting capacitor of following capacity for water cooler 1/0.5TR and 0.33 capacity complete all as specified and directed.
for 40 to 100 mfd and -ditto-
For 100 to 120 mfd and -ditto-
M&L for replacement of running capacitor of following sizes suitable for water cooler compressor sealed unit 1/0.5 / 0.33 TR capacity complete all as specified and directed.
For 04 to 06 mfd and -ditto-
For 10 mfd and -ditto-
M&L for replacement of new condensing fan motor cap 1/10 HP for water cooler complete all as specified and directed.
M&L for replacement of new condensing fan motor cap 1/32 HP for water cooler complete all as specified and directed.
M&L for replacement of thermostate switch of water cooler of any size of compressor unit capacity complete all as specified and directed.
M&L for replacement of over load protector suitable for water cooler compressor unit of any capacity complete all as specified and directed.
M&L for replacement for starting relay complete water cooler compressor unit of any capacity complete all as specified and directed.
M&L repair/replacement of PVC drain pipe 2 M long of size 32/ 40 mm dia complete all as specified and directed.
S&F in replacement PVC float valve 15 mm dia with nipple and long screw complete in water cooler complete all as specified and directed.
S & F indoor unit of split type AC of any capacity complete all as specified and directed.
S & F Air filter for window & split type AC of any capacity complete all as specified and directed.
Cleaning and servicing complete of AHU and duct of central AC plant 130 TR capacity with soft brush & using air pressure gun complete all as specified and directed.
S&F in replacement of Air filter Size 19.5"x23.5" x 2",23.5"x23.5" x2", 19.5"x15.5"x2" and 19.5"x19.5"x2" 10 Micron washable type for proper functioning of air circulation in AHU for 130 TR AC Plant complete all as specified and directed.
M & L for scrubbing the corrode parts of cooling tower, pipe lines and applying two coats of synthetic enameled paints complete all as specified and directed.
S&F voltage stablizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stablized at 230 V with accuracy of + 2.5 % and of capacity 4.0 KVA complete all as specified and directed.
S&F Constant voltage trasfomer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 500 V with output voltage stablized at 240 V with accuracy of + 2.5 % and of capacity 4.0 KVA complete all as specified and directed.
M & L for 3 pole contactor 440 V ,coil voltage 220,25 A complete all as specified and directed.
M & L for 3 pole contactor 440 V ,coil voltage 220,32 A complete all as specified and directed.
M & L for 3 pole conntactor 440 V ,coil voltage 220,50 A complete all as specified and directed.
M & L for Over load relay 16A to 24 A complete all as specified and directed.
M & L for Over load relay 24 A to 32 A complete all as specified and directed.
M & L for timer delay relay 9 Sec to 30 Sec complete all as specified and directed.
M & L single phase preventor ,over volt, low volt ,phase reverse relay complete all as specified and directed.
M&L for rewinding of induction motor,3 phase,440 Volts with super enamelled copper conductor of existing size and gauge including varnishing,drying,cleaning of slots,repair to damage slots, maching work of shaft for fixing of bearing and other required work for smooth functioning of motor,testing at work shop complete all as specified and directed of the following capacity of motors:-
For 20/25 HP cap and -ditto-
For 10 HP cap and -ditto-
For 7.5 HP cap and -ditto-
Disconnecting , decoupling , dismantling of monoblock pump motor of following capacity from foundation/base frame,transporting to workshop for repair & back at site after repair and refixing the same on its position,recoupling,reconnection,testing of commissioning complete all as specified and directed.
For 20/25 HP cap and -ditto
For 10 HP cap and -ditto
For 7.5 HP cap and -ditto
M&L for dismantling of centrifugal /monoblock pumpset 20/25 HP cap transporting to work shop taking out defective parts and replace the defective parts in pump set, metling, grinding, machining work, as required to make as per original shape and size and assembly for pump set , testing at workshop complete all as specified and directed.
S& F outdoor unit of split AC complete 1.5 TR complete all as specified and directed.
S&F in repair inner shell (tank) for Geysers of 25/50 Ltr capacity made out of stainless steel complete all as specified and directed.
S&F in repair of Heating element 1.5/2.0 KW capacity, cup type,triangular/round/thread type for Geysers complete all as specified and directed.
S&F in repair of Heating element 3 KW capacity, thread type for solar water heater complete all as specified and directed.
Supply only Geyser inner assembly of stainless steel of 06/08/09 holes with nut, bolts, stud, washer complete all as specified & directed.
S&F in repair PVC connection 15 mm dia, 600 mm long for hot water all as per site requirement complete all as specified and directed.
Supply and fix in repair thermostat switch ISI marked (adjustable type) for Geysers complete all as specified and directed.
S & F in replacement hot water apparatus 25 Ltr cap complete all as specified and directed.
S&F solar rod ETC type 500 Ltrs cap solar water heater complete all as specified and directed.
Taking down ceiling/exhaust/cabin fans from existing location including removing electric connection, capacitor and dismantling of ceiling fan any sweep complete including checking of bearing/bushes, cleaning the fan blade with clear water, scraping the fan blade, placing the bearing, bush, capacitor complete and reassembling the ceiling fan after greasing, oiling, testing and refixing the fan after necessary repair complete all as specified & directed. (Note : Ball bush bearing, capacitor and rewinding will be measured and paid separately under respective items as rewinding of supply only here-in-after).
Rewinding of ceiling fans of 1200/1400mm sweep with super enameled copper wire of existing gauge including varnishing, insulation, taping, writing MES No with synthetic enameled paint and testing complete all as specified & directed.
All as per item No. 63 above but cabin fan/exhaust fan of 300mm sweep.
Supply only capacitor 2.5 mfd complete all as specified and directed.
M & L for cleaning and servecing of solar water heater complete all as specified and directed.
Supply and fix stand set for outdoor AC unit complete all as specified and directed
M&L for cleaning, servicing of cooling tower of Chiller Plant with cleaning agent complete pipe lines, and FRP tank, greasing, servicing of cooling tower etc. & make the necessary alignment complete all as specified and directed.
De-scaling of complete system of chilled water supply of 130 TR Plant and return line of all 2 magz incl cleaning of strainers , using velin clean as descaling compound and removing all waste/foreign material (Make Carrier , model 30 HXC) complete all as specified and directed.
M & L for compressor oil for screw type compressor of 65 TR unit of central AC plant ( Make Carrier,Model 30HXC) complete all as specified and directed.
Supply and fix pressure tansducer for chiller/condenser in and out as per sample for 65 TR unit of central AC plant ( Make Carrier,Model 30HXC) complete all as specified and directed.
Supply and fix flow switches in and out as per sample for 65 TR unit of central AC plant ( Make Carrier,Model 30HXC or equivalent as approved by GE.) complete all as specified and directed.
Supply and fix Discharge/suction/oil/dust transmittor for 65 TR unit of central AC plant ( Make Carrier,Model 30HXC or equivalent as approved by GE) complete all as specified and directed.
Supply and fix chiller safety switch as per sample for 65 TR unit of central AC plant ( Make Carrier,Model 30HXC) complete all as specified and directed.
Supply and fix condenser safety switch as per sample for 65 TR unit of central AC plant ( Make Carrier,Model 30HXC or equivalent as approved by GE) complete all as specified and directed.
Supply and fix oil solenoid valve for 65 TR unit of central AC plant ( Make Carrier,Model 30HXC or equivalent as approved by GE) complete all as specified and directed.
Supply and fix compressor SCPM card for 65 TR unit of central AC plant (Make Carrier,Model 30HXC or equivalent as approved by GE) complete all as specified and directed.
Supply and fix oil pump for compressor of 65 TR unit of central AC plant (Make Carrier,Model 30HXC or equivalent as approved by GE) complete all as specified and directed.
Supply and fix internal oil filter for compressor of 65 TR unit of central AC plant (Make Carrier,Model 30HXC or equivalent as approved by GE) complete all as specified and directed.
Supply and fix external oil filter for compressor of 65 TR unit of central AC plant (Make Carrier,Model 30HXC or equivalent as approved by GE) complete all as specified and directed.
Supply and fix drier core for 65 TR unit of central AC plant (Make Carrier,Model 30HXC or equivalent as approved by GE) complete all as specified and directed.
Supply & fixing in replacement of water pressure gauge 0 to 150kg/cm2 complete all as specified and directed.
Supply & fixing in replacement of water gauge 0 to 150kg/cm2 complete all as specified and directed.
Supply & fixing in replacement of flow swtich Model WFS600 ,150PSI,1000C 1" NPT 15A 250V complete all as specified and directed.
Supply & fixing in replacement of Perised PVC cooling fills size 600x300x150mm in bluih sheding having thicness 02mm and in hexagonal shape suitable for cooling tower of Central AC Plant complete all as specified and directed.
Taking proper shutdown unscrewing of strip heater finnel type 3 KW disconnecting electric connection and replacing by the new one strip heater by giving electric connection and screweing nut bolt properly and testing complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed. 2. Unless otherwise specified the rates for PCC/RCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule "A" notes for details.
M/S DHEER ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .