Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | LI₹6.9 LAccepted-AOC PARAYIL VALAPPIL VEEDU KOOTANAD P O PALAKKAD 679533 | PALAKKAD | KERALA | 679533 | LI | Accepted-AOC least value | |
| 2 | Rejected-Technical | - | Rejected-Technical HIGH BID RATE | |
| 3 | Rejected-Technical SUBHADRA K T CHAVAKKAD | - | Rejected-Technical HIGH BID RATE | |
| 4 | Rejected-Technical | - | Rejected-Technical HIGH BID RATE |
Tender Value
₹8.5 L
EMD Value
₹21,173
Closing Date
21 Oct 2023, 6:00 pmClosed
ASSISTANT ENGINEER
LIDEW SECTION CHALISSERY GP
Annual Plan-CHALISSERY GRAMAPANCHAYATH 2023-24 MCF SHED NIRMANAM-PROJECT NO 220/23-General Civil Work
2023_LSGD_611985_1
25/2023/AE/LIDEW/CHYPHASE1
Open Tender
Civil Works - Buildings
Item Rate
180 days
CHALISSERY GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,870
₹21,173
11 Feb 2025
11 Oct 2023
27 Oct 2023
11 Oct 2023
21 Oct 2023
11 Oct 2023
Amount
CONSTRUCTION SHEET ROOFED BUILDING
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
OD175226/2023-2024:Providing and fixing precoated galvanised iron profiles sheets (size shape, and, pitch of corrugation as approved by engineer in charge) .3mm(+.05%),in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat of 15-18 microns. Sheet should be protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 m or as desired by Engineer in charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x5mm) with EPDM seal complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required.
NARAYANAN T
SHAFEEK.A.M
jithin k
Bidder Name
NARAYANAN T
MOHAMMED ALI P.V
SHAFEEK.A.M
jithin k
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_914713.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .