| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC being reasonable | |
| 2 | L2₹41.0 L+₹6.9 L (20.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹42.2 L+₹8.2 L (23.9%)Rejected-Finance 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
27 Sept 2024, 6:00 pmClosed
GE (KH) YOL
GE (KH) YOL, YOL CANTT, HP
Repair/Maint and Improvement of E/M installation pump motors, water supply installation fencing and other connected works and Repair water supply tank, pipe, drain, channel, tank water proofing and Repair/replacement E/M installation at YOL CANTT
2024_MES_669313_1
GE/Y-59/2024-25
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (KH) YOL
₹92,000
Yes
18 Oct 2024
31 Aug 2024
28 Sept 2024
31 Aug 2024
27 Sept 2024
14 Sept 2024
Amount
PART-I:- Taking out centrifugal pumping set 30 HP, three Phase from foundation, transporting to workshop opening for inspecting all parts to identify defective parts cleaning and keeping aside serviceable parts in safe custody, rewinding with super enamelled copper wire as per existing size and general servicing/overhauling of pump, electric motor & Re-assembling of motor and pump, transporting back to pump house and connecting with pipes and electric connections and testing for performance, complete as directed and directed by Engr-In-Charge. (Note : Parts to be replaced measured separately)
Supply and fixing in replacement of Ball bearing suitable for 30 HP motor, complete all as spccified and directed . Make -NBC/SKF
Supply and fixing in replacement of Gun Metal shaft bush for 30 HP pump with lock key, complete all as specified and directed.
Supply and fixing in replacement Impeller for 30 HP pump, complete all as spccified and directed .
Repair with opening taking out carefully using chainpully of 5.0 Ton for the submersible pump & Motor 15 HP, 415V, 3Phase, 50Hz, complete all as specified and directed by Engr-in Charge. Note: Unserviceable spare parts shall be measured and paid seperately.
Rewinding of motor with super enamel copper wire with existing gauge, turns, providing sleeve, varnishing with 'E' class insulation varnish including cutting and taking out existing burnt out winding, cleaning complete including testing after rewinding copper at user site and complete testing.
S&F in Repair/replacement of Star Delta starter for pump motor 15.0 HP capacity at user site and complete testing. (Make: L&T/Havells/Standard)
S&F in repair/replacement of 15 HP pump bearing 6207, 6208 at uses site and complete testing.
S&F in replacement of pump coupler at user site and complete testing all as directed.
S&F in replacement of thrust washer at user site and complete testing all as directed.
Complete reassembling & testing of submersible pump with motor and reconnecting with GI pipe upto 100mm dia complete all as directed.
Replacement of CI flange with gaskit 100 mm dia with nut, bolts and washer complete.
Repair with opening taking out carefully using chainpully for the submersible pump & Motor 5 HP, 415V, 3Phase, 50Hz complete all as specified and directed by Engr-in Charge. Note: Unserviceable spare parts shall be measured and paid seperately.
S&F in Repair/replacement of Star Delta starter for pump motor 5 HP capacity at user site and complete testing. (Make: L&T/Havells/Standard)
S&F in repair/replacement of pump bearing 6207, 6208 at uses site and complete testing.
S&F in replacement of water sheal for water leakage at user site and complete testing.
S&F in replacement of bush 100mm long and dia 20mm for pump motor at user site and complete testing.
Rewinding of motor with super enamel copper wire with existing gauge, turns, providing sleeve, varnishing with 'E' class insulation varnish including cutting and taking out existing burnt out winding, cleaning complete including testing after rewinding copper at user site and complete testing.
Greasing and servicing of submersibe motor 5HP and centrifugal multistage pumping at user site and complete testing.
S&F in replacement of preventor system supply 3 phase, 415V, AC with existing specification at user site and complete testing.
Replacement of gaskit suitable for 80mm dia pipe line with 4 Nos nut, bolts and washer complete as per existing size.
Complete reassembling and testing of submersible pump and motor 5 HP and reconnecting with GI pipe of 40mm dia medium grade.
S&F in replacement of MCCBs TP 160A, 415V, 36 KA, complete all as specified and directed. (Make:- L&T/Havells/Standard)
S&F in replacement of MCCBs TP 100A, 415V, 16 KA, complete all as specified and directed. (Make:- L&T/Havells/Standard)
S&F in replacement of MCCBs TP 63A, 415V, 16 KA, complete all as specified and directed. (Make:- L&T/Havells/Standard) at user site and complete testing.
S&F in replacement of 6.00 sqmm multistranded copper conductor 1100 volts grade PVC insulated unsheathed cable 3 core with PVC concealed conduit 20mm dia and providing proper connection from star delta starter to pump motor 15HP capacity at user site and complete testing, complete all as specified and directed.
S&F in replacement of 4.00 sqmm multistranded copper conductor 1100 volts grade PVC insulated unsheathed cable 3 core with PVC concealed conduit 20mm dia and providing proper connection from star delta starter to pump motor 5HP capacity at user site and complete testing, complete all as specified and directed.
S&F in replacement of 2.50 sqmm multistranded copper conductor 1100 volts grade PVC insulated unsheathed cable 2 core with PVC concealed conduit 20mm dia and providing proper connection from star delta starter to pump motor 5HP capacity at user site and complete testing, complete all as specified and directed.
Opening, dismantling and taking out of unserviceable self priming monoblock pump 0.5/1.00/2.00 HP assembly complete with motor and replacement of undermentioned unserviceable parts, complete all as specified and directed by Engr-In-Charge.
Taking out of unsv burnt motor of self priming monoblock pump 0.5/1.00/2.00 HP, 220 Volts, single phase and transporting to motor rewinding shop for rewinding using super enameled varnished winding copper wire of same guage including insulation, fire proof sleeves and ball bearing -02 Nos and reinstallation at same position/location and complete, testing on user site, complete all as specified and directed by Engr-In-Charge.
Taking out and replacement of unsv impeller rotor of self priming monoblock pump 0.5/1.00/2.00 HP, 220 Volts, single phase and reinstallation at same position with testing, complete all as specified and directed by Engr-In-Charge.
Taking out and replacement of unsv automatic pressure control assy of self priming monoblock pump 0.5/1.00/2.00 HP, 220 Volts, single phase and reinstallation at same position with testing, complete all as specified and directed by Engr-In-Charge.
Taking up or down steel tubing and connection of size 15mm dia.
S & F GI tubing, medium grade with all fittings and fixed of size nominal bore 15mm complete all as specified and directed.
S & F in replacement stop valve of bore 15mm, screwd down high pressure, with crutch or butterfly handle,screwed bith ends for iron pipe or for unions, complete all as specified and directed.
Repair with opening and taking out carefully of Monoblock Pump & Motor 5.0 HP, 415V, 3 Phase, 50Hz, complete all as specified and directed by Engr-in Charge.
Opening, taking out and S&F in replacement of motor Impaller 100mm long bore dia 20mm with gaskit and thrust washer (as per existing size) & stage at user site and complete testing.
Opening, taking out and S&F in replacement of pump bearing 6207, 6208 at user site and complete testing.
Opening, taking out and S&F in replacement of water sheal for water leakage at user site and complete testing.
Opening, taking out and S&F in replacement of bush 100mm long & 20mm for pump motor at user site and complete testing.
Opening, taking out and S&F in replacement of motor fan, outer dia 100mm & bore dia 20mm at user site and complete testing.
Opening, taking out and rewinding of motor with super enamel copper wire with existing gauge, turns, providing sleeve, varnishing with 'E' class insulation varnish including cutting and taking out existing burnt out winding, cleaning complete including testing after rewinding copper at user site and complete testing.
Greasing and servicing of monoblock motor 5.0 HP and centrifugal multistage pumping at user site and complete testing.
Opening, taking out and S&F in replacement of preventor system supply 3 phase, 415Volt, AC with esising spacification at user site and complete testing.
Opening, taking out and S&F in replacement of Star Delta starter for pump motor 5.0 HP capacity at user site and complete testing. (Make: L&T/Havells/Standard).
Replacement of gaskit suitable for upto 80 mm pipe line with 4 Nos nut bolts and washer as per existing size complete.
Complete reassembling & testing of Submersible Pump & motor 5.0 HP and reconnecting with GI pipe 40mm dia.
Repair & replacement of unservicable Brush cutter with opening, dismantling, taking down under mentioned spares parts/assemblies, complete all as specified and directed by Engr-in Charge.
Replacement of Stainless steel treaming rod with complete set.
Replacement of starting switch complete.
Replacement of Oil seal kit complete.
Replacement of Ball bearing complete.
Replacement of treaming wheels complete.
Repair of piston kit complete.
Replacement of crank shaft complete.
Replacement of Clutch plate complete.
Replacement of Recoil Startor complete.
Replacement of Carburator complete.
Replacement of Plug complete.
Replacement of Filter complete.
Replacement of Double shoulder belt complete.
Repair of unservicable electric Brush cutter with opening, dismantling, rewinding including replacement of all unsv parts/assemblies, complete all as specified and directed by Engr-in Charge.
Repair/replacement of Chlorination Plant including opening, dismantling and taking down and supply & fixing in replacement of undermentioned spare parts with installation, testing, complete all as specified and directed by Engr-in Charge.
Measuring glass holder Pt.No.33340.
Clamp screw for glass Pt.No.28804.
Teflon Vent tube 3/8.
Diapharagm front Plate Pt.No.M-369.
Diapharagm Back Plate Pt.No.B-126.
Plant Connecter Assembly(SS) Pt.No.M-211.
Gas Pressure Guage B-314.
Inlet Valve G5/8 Pt.No.29714.
Material and labour for two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface of electric panel, pipes, MS items etc including preparation of existing surface, complete all as specified and directed.
Material and labour for two coats of synthetic enamelled paint over a coat of red oxide primer on Motors of different capacity including pipes, MS items etc. including preparation of existing surface, complete all as specified and directed.
Opening dismentling of electric motor and transporting to civil rewinding shop for rewining of electric induction motor of capacity 1.5 HP, 415 volts, 3-phase using super enemeled barnished winding copper wire of same size including proper insulation, sleeves etc complete all as specified and as directed.
S & F in replcement cable XLPE insulted, armoured heavy duty electric cable with aluminium conductor, 1100volts grde, cross-sectional area 25 sqmm, 3.5 core, complete all as specified and as directed.
Replcement of wooden planks of size 1.2 m X 0.15m X 0.025m as per existing user site, complete all as specified and directed.
Supply & fixing of contact relay 415V, three phase suitable for 15 HP motors as per existing specification, complete all as specified and directed.
Supply & fixing of contact relay 415V, three phase suitable for 5.0 HP motors as per existing specification, complete all as specified and directed.
Supply & fixing of contact relay 415V, three phase suitable for 30.0 HP motors as per existing specification, complete all as specified and directed.
S & F Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for Brick masonry valve pit of size 120x120x120cms (internal dimension) with earth work in any type of soil, plain cement concrete M-10 type C-2 as in foundation, brick work in cement mortar 1:6 (01 cement : 06 coarse sand) 23cms thick, 15mm thick plaster in cement mortar 1:4 (01 cement : 04 coarse sand) internally and externally flush pointed in same mortar as the work proceeds flooring shall be 40mm thick in plain cement concrete M-15 (Nominal mix) laid over 75mm thick hard core top cover shall be made out of mild steel sheet 3.15mm thick fixed in angle iron frame made out of angle size 40x40x6mm with two number of hinges on one side and locking aggangement at other side with 50mm pad lock complete including painting with two coats of sythetic enamel pait over a coat of red oxide primer complete all as specified.
Dismantling plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F of Cast iron sluice valve 250mm dia (ISI marked) PN -1.6 flanged with Gun metal spindle including all fittings such as nus, bolts, washers, tec with iron wheel confirming to IS-780/14846, including taking out old unserviceable sluice valve of any pattern, including excavation and earth work, complete with all as specified and as directed by Engr-in-Charge.
M&L Cast iron sluice valve 150mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (flanged joints excavation and earth works including quoted rates), complete all as specified and as directed by Engr-in-Charge.
M&L Cast iron sluice valve 100mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (langed joints excavation and earth works including quoted rates), complete all as specified and as directed by Engr-in-Charge.
M&L Cast iron sluice valve 80mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (langed joints excavation and earth works including quoted rates), complete all as specified and as directed by Engr-in-Charge.
M&L Cast iron sluice valve 50mm dia (ISI marked) with steel spindle of flanged ends drilled complete class PN -1.6 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, mild steel nuts bolts washers etc including taking out old unserviceable sluice valve of any pattern (langed joints excavation and earth works including quoted rates), complete all as specified and as directed by Engr-in-Charge.
M&L for Cleaning of surrounding area near water supply pipe lines, motors including plants and vegetation, complete all as specified and as directed by Engr in charge.
S&F bracket made of 25 mm dia GI pipe light grade ISI marked 1.20 mtr long bent to shape with 2 Nos MS clamp duly painted with two coat of aluminium paint over one coat of red oxide, made of 32x5mm FI with nuts, bolts and washers suitable for off size HT/LT poles including dismantling existing bracket and refixing old/new fitting all as specified and directed.
Supply and fixing in replacement of LED street light fitting 70 watt complete with Pressure die cast aluminum housing enclosed with Heat resistant glass cover in frame complete with IP 65 protection and making electrical connection with using copper conductor 23/ 0.0076 round PVC insulated and sheathed three core cable including mounting on pole, complete all as specified and directed. (Make: C&S Cat Part No. LTESSI45WLED or equivalent in Bajaj/Wipro/Philips.
Supply and fixing in replacement of LED street light fitting 45 watt complete with Pressure die cast aluminum housing enclosed with Heat resistant glass cover in frame complete with IP 65 protection and making electrical connection with using copper conductor 23/ 0.0076 round PVC insulated and sheathed three core cable including mounting on pole, complete all as specified and directed. (Make :C&S Cat Part No. LTESSI45WLED or equivalent in Bajaj/Wipro/Philips.
Supply and fixing in replacement of Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with MS base plate, finial taper plug, bolts, nuts, screws and top cover, with single swan nec all as specified and including the following:- (a) Excavation in trenches not exceeding 1.5 mtr wide and 2 mtr deep for pole foundation and getting out in soft/loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exc 25cm thick and disposal of surplus soil to a distance not exc 50 mtrs. (b) Material and labour for providing PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section planting depth 1.8 mtr for concrete casing the pole upto GL complete all as directed. (c) Material and labour for providing PCC 1:2:4 type B-2, using 40mm graded stone aggregate for plinth block/collar above GL 300 mm high and 450mm dia all as directed. (d) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer, preparation of surface including painting of 30cm wide blue bands 3 Nos with synthetic enamel paint in alternate layer upto the height of 1.5m above plinth block. (e) Material and labour for writing letter or figures (Block, Roman, italic as Indian) with thick synthetic enamel paint of approved shade not exc height in numbering of pole all as directed. (f) drilling a 02 Nos of hole to LT Pole (one hole near street light bracket and another near bus bar at bottom side) for insert of cable for street light.
Supply and fixing MCB DB SPN 12 way with 200 Amps rated bus bar 240 V double door when MCBs to used, complete all as specified and directed.
Supply and fixing MCB SPN 'C' series 40 Amps (As ordered) suitable for 240/ 440 volts, 50 HZ 10 KA breaking capacity, complete all as specified and directed.
Supply and fixing MCB SP 'C' series 6 Amps to 32 Amps suitable for 240/ 440 volts, 50 HZ 10 KA breaking capacity, ISI marked (IS 8828), complete all as specified and directed. Make:- Hevells, L&T, CG
M & L for Point wiring for one light controlled by one switch with 1.50 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) in and including PVC concealed conduit with sunken box suitable for modular switches and sockets, including 1.50 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth duly alongwith modular cover plate (inner & outer), complete all as specified and directed. Note : (a) Insulation test of point wiring (b) colour coding is to be maintained. (Ph-Red, N-Black, Half -Yellow, Earth- Green.
M & L for Point wiring with 2.50 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC concealed conduit with sunken box suitable for modular switches and sockets for 5 pin 15 amps socket outlet, including 2.50 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth duly alongwith modular cover plate (inner & outer), complete all as specified and directed. Note : (a) Insulation test of point wiring. (b) colour coding is to be maintained (Ph-Red, N-Black, Earth- Green).
S&F for welded steel wire fabric not exceeding 4Kg/Sqm complete to steel members, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, removing surplus soil to a distance not exceeding 50m, complete all as specified and directed.
Removal of surplus soil to be distance n.exc 50M and depositing where directed at a level n.exc 1.5m high from the starting point, complete all as specified and directed.
M&L for PCC type C-2 1:3:6 with using 40mm graded stone aggregate as in foundation and mass concrete, complete all as specified and directed.
Repair and replacement of existing fountain including GI tubing, electric motor, nozzles to spread the water all around in an aesthatical appearance, complete all as specified and as directed by Engr-In-Charge.
Supply, install, testing and commissioning of LT Panel board, CPRI approved, weather/vermin proof, made out of 2mm thick CRCA sheet, factory assembled cubicle pattern modular and compartmentalized construction, Indoor type, with front side hinged door with locking arrangement, floor mounted free standing type, duly powder coated, 3 phase and neutral 400 amps current carrying capacity copper bus bar with epoxy insulated coating with colour code and insulated support with copper earth bus of size 25x3mm with terminal switch, cable galleries, inter connecting bus bar connection/linkage, complete with the following switch gears/accessories and mounting the panel board on floor 30cm above gorund level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board all as directed :- (a) MCCB, 415 Volt, 4 pole, of capacity 160 Amps, 36 KA - 1 No. (Incoming). (b) MCCB, 415 Volt, 3 pole, of capacity 100 Amps, 16 KA - 1 Nos (Out Going). (c) MCCB, 415 Volt, 3 pole, of capacity 63 Amps, 16 KA - 3 Nos (Out Going).
M&L for PCC type D-2 M-7.5 with using 40mm graded stone aggregate as in foundation and mass concrete, complete all as specified and directed.
Mild steel angle iron work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. Note:- Unit rate is also including locking holes after fixing of barbed wire and welding to bent portion.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, including taking dismantling old chain line fencing, complete all as specified and directed.
Supply Only Chain link hot dipped galvanisd fencing, any size or type, complete all as specified and directed.
Mild steel 10mm dia of neck and length exc 5cm but n.exc 10cm screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and directed.
Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, conforming to Fe 410-W Gde E-250, Quality A, complete all as specified and directed.
1.60mm thick Mild steel, plain, black sheet in wall cladding, steel gates, covering to door shutter, covering to door chowkhats and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, stopped ends etc. as required, complete all as specified and directed.
Applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel or steel based surfaces of any description, exceeding 10cm width or girth including preparation of surfaces, complete all as specified and directed.
Plain cement concrete M-15, nominal mix, type B-0, using 12.50mm graded mechanically crushed stone aggregate as in flooring, 25mm thick, complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying two coats of oil bound distemper to achive smooth surface, complete all as specified and directed.
Three coats of white wash on old plastered ceiling surfaces including preparation of surfaces, complete all as specified and directed.
Preparation of newly plastered wall surfaces and appling two coats of cement base paint over a coat of primer, complete all as specified and directed.
S&F Tyre of size 16 inches for existing Trolley mounted Transformer including taking out old tyres, complete all as specified and directed by Engr-In-Charge.
Replacement of earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.30mm thick buried directly in ground to a depth not less than 2.25m below normal ground level with top edge of earth plate at a depth not less than 1.50m below ground level, earth plate surrounded by 15cm thick packed layer of charcoal and common salt alternatively upto 90cm and connected with and including GI strip of size 32x6mm earthing dia by means of bolts, nuts, check nuts and washers of GI pipe 40mm bore medium grade for protection of GI wire from earth plate to testing point for protection, 20mm bore GI pipe medium grade for water with wire mesh and funnel for watering including necessary excavation and earh work, PCC chamber 1:3:6 type C-2 with RCC cover complete all as shown in electrical plate No. 03 of MES Schedule Part-I, complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC 1:2:4 type B-1, 80mm thick reinforcement with 8mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii) Earth electrodes shall be protected upto test point using necessary arrangement with suitable size GI pipe upto 7.50m and the rate includes in the unit rate of item. (iii) Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and rate includes in the unit rate of item. (iv) The earth chamber shall be condtructed 5m away from the edge of the bldg pit and the cost of the same is deemed to be included in the rate quoted for this item.
High performance IP66, 45W LED street light fixture with housing made of die cast aluminium with street optic lens and glass diffuser for uniform light distribution and inbuilt Surage Protection Device (SPD) suitable for bracket of dia Ø 35/40 mm on existing poles, complete all as specified and directed by Engr-in-Charge. Make:- Havells Cat Part No. ENDURASUNDOWNSL45WLED765PASYBOTG or Bajaj Cat Part No. ENXT P 54L WH PO PC SD MT or Orient Cat Part No. LSFT-045-C or equivalent make mention in Appx 'C'.
High performance IP66, 60W LED street light fixture with housing made of die cast aluminium with street optic lens and glass diffuser for uniform light distribution and inbuilt Surage Protection Device (SPD) suitable for bracket of dia Ø 35/40 mm on existing poles, complete all as specified and directed by Engr-in-Charge. Make:- Havells Cat Part No. ENDURASUNDOWNSL60WLED765PASYBOTG or Bajaj Cat Part No. ENXT P 72L WH PO PC SD MT or Orient Cat Part No. LSFT-060-C or equivalent make mention in Appx 'C'.
Taking down the old Unserviceable and high energy consuming existing HPSV/MH/4x14W Street Light fittings of any make or any capacity from the pole of 9m after disconnecting the electric connection carefully, complete all as specified and directed.
M&L for fabrication of street light bracket made out of GI pipe 32/40mm dia medium grade GI Pipe minimum 1.5 Mtr long including fixing with 02 Nos MS clamps made out of flat iron of size 30mm x5 mm with nut bolts and washer incl painting work, complete all as specified and directed, Including taking down old one.
Excavation in trenches n exc 1.50 metre wide & n exc 1.50 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n exc 1.50 metre in depth and getting out in any type of soil, complete all as specified and directed.
Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed.
Rendering cement plaster 10mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) on fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for filling of soil/brick bat/old retrived stones for filling of platform/foundation as required at site 50mm thick, complete all as specified and as directed by Engr-In-Charge.
Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed.
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) on fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement with WPC, complete all as specified and directed. Note:- water proofing compound shall be measured and paid separately.
Rendering cement plaster 5mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) on fair faces of RCC surfaces and including applying sement slurry in slab or ceiling etc., complete all as specified and directed.
Supply only liquid water proofing compound, complete all as specified and directed.
Preparation of newly plastered wall surfaces and appling two coats of cement base paint over a coat of white wash, complete all as specified and directed.
Preparation of old decorated plastered or unplastered surfaces including cleaning by brooming down or with steel wire brushing scraping down smoke soot, moulded moss and efflorescent salts and cleaning oil and greasy spots and applying one coat of cement base paint on external wall surfaces, complete all as specified and directed.
Three coats of white wash on newly plastered or un plastered, previously undecorated ceiling surfaces including preparation of surfaces, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed.
Glazed coloured tiles of size 300x200x7mm thick as in vertical surfaces such as jointed in neat cement slurry and pointed with coloured cement to match and including 10mm thick plastering in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed.
75mm thick Plain cement concrete M-7.5 nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in sub base, complete all as specified and directed.
50mm thick Plain cement concrete M-15 nominal mix, B-1, using 20mm graded mechanically crushed stone aggregate as in flooring, foundations, filling and mass concrete, finished even and smooth, complete all as specified and directed.
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5cm deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), complete all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars, copings, etc. complete all as specified and directed.
Rendering plaster 15mm thick in cement mortar 1:6 (1 cement :6 coarse sand) on other than fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for, complete all as specified and directed.
Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate as) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
Providing precast reinforced cement concrete M-15, type B-1 (using 20mm graded mechanically crushed stone aggregate) as in deck slabs, shelves, cover slabs (for man holes cover etc.) and similar works bedded and jointed in cement mortar (1:4) (1 cement : 4 coarse sand), complete all as specified and directed. Note :- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed.
TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns ends and binding with mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), etc. For fair finished flat surfaces of concrete, complete all as specified and directed.
Plain cement concrete M-10 nominal mix, type C-1 using 20 mm graded mechanically crushed stone aggregate as in surface channel and drains, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and directed.
Extra for forming fair finished drain or channel 45cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description, complete all as specified and directed.
Rolled mild steel section in joist channel, angle or tee section fixed independantly without connection plate etc. (cut to ordinary lengths) conforming to grade Fe.410-0.Gde-E-250, quality A steel work, complete all as specified and directed.
Preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 110mm, including taking down old pipe, complete all as specified and directed.
Taking up 150mm cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead, complete all as specified and directed.
Cast iron pipes with spigot and socket ends centrifugally cast. Class LA, in any length, laid in trenches of 150mm dia bore, complete all as specified and directed by Engr-In-Charge.
Cast iron fittings for spigot and socketed pipe i.e. bends (any type radius and angle) tapers any type (straight, bend, increasing decreasing or double socket etc) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socker and spigot) collars, caps and plugs up to 150mm dia, complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Chequered cement concrete tiles machine pressed of size 20cmx20cmx25mm thick with grey cement, set jointed & pointed in neat cement slurry mixed with pigment to match the shade of the slab in floors laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Plain cement concrete M-15, nominal mix, B-0 using 12.50mm graded mechanically crushed stone aggregate as in lintels upto 1.50 metre clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as specified and directed. Note :- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
Repairing/treatment of all cracks, joints and honey combs with polymer modified fiber reinforced morter as per methodology specified by the manufacturer. Average depth of honey comb repairing minimum 20-25mm thick, complete all as specified and directed by Engr In Charge. Make:- Fosroc/BASF/STP or equivalent
Taking down cement plaster/decayed concrete from RCC roof projections/upward parapet walls/ down ward facia/soffits and fins of RCC chajjas /beams/columns/balconies , RCC waterr storage etc. Supply and fixing by means of nailing wire netting of galvanised wire 1.40 mm dia and mesh size 20 mm and brushing neat cement slurry with 3.00 kg of cement/sqm and M & L for 20 mm thick cement rendering in two layers of 10 mm each (top/final layer shall be rendered after final setting of under layer) in Cm 1:3 on concrete surfaces including scaffolding at a height upto 7.00 mtrs. etc, complete all as specified and directed.
M&L for Cementitious Coating - Floor (Horizontal/Vertical Area) : Prime the area with slurry by mixing one part of acrylic polymer with two parts of neat cement i.e. in the ration 0.50kg acrylic polymers and 1 kg cement. Apply two component cementitious elastomeric polymers base water proof coating on clean and dampen surface with stiff fibre brush. Apply first coat @ 1.25kg per sqmt per coat in one direction . Apply second coat when the first coat is touch dry @ 1.25Kg per sqm per coat in perpendicular direction to first coat direction. Allow to dry for 24hrs before moist curing. Do not apply water through a hose or pressurized nozzle. Protection screed 25mm thick M-15 grade screed adding of integral water proofing liquid 200ML per 50Kgs of cement PCC to protect the treated surface on all horizontal surface. Work should be process with guideline as per methodology, complete all as specified and directed by the Engr-in-Charge. Make :- FOCROC/BASF/STP or its equivelant.
M&L for Epoxy Coating (Approved by CFTRI) PRIMER : Apply two component penetrative epoxy based primer @ 160gms per sqmt on cured surface. Note, the moisture should not be more than 5%. EPOXY COATING : Apply food grade epoxy coating tested by CFTRI @ 500 Gms per Sqmt in two coats. Apply two coats at right angles to each other. This way the second will cover any blemishes of the first coat. Allow first coat to become tack free before the second coat is applied. Work should be process with guideline as per methodology, complete all as specified and directed by the Engr-in-Charge. Make :- FOCROC/BASF/STP or its equivelant.
M&L for Polyurethane Top Coating (Approved by CFTRI) PRIMER : Apply two component penetrative Polyurethane Top Coating @ 160gms per sqmt on cured surface. Note , the moisture should not be more than 5%. PU COATING : Apply two component, liquid aliphatic polyurethane based UV and weather resistant coating approved by CFTRI @ 300 Gms per Sqmt in two coats. Apply two coat at right angles to each other. This way the second will be cover any blemishes of the first coat. Allow first coat to become tack free before the second coat is applied. Work should be process with guideline as per methodology, complete all as specified and directed by the Engr-in-Charge. Make :- FOCROC/BASF/STP or its equivelant.
M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @ 1.43/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over old painted surfaces including preparation of old surfacs after complete removal of existing treatment, complete all as specified and directed by the Engr-in-Charge.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads, fixed in repairs, complete all as specified and directed.
surinder kumar jindal & bros. (BID ID -3117299)
Eshaan Construction Co. (BID ID -3117512)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .