Loading…
Loading…
Tender Value
₹1.6 L
EMD Value
₹3,120
Closing Date
28 Sept 2026, 6:00 pm6d left
Executive Engineer PWD Electrical Div. Ist Jodhpur
Executive Engineer PWD Electrical Div. Ist Jodhpur
Air conditioning Work in Gynecology Operation Theater at Jawahar Hospital, Jaisalmer
2026_CEPWD_598594_4
NIT No.26/2026-27 of EE PWD Elect.Dn.I Jodhpur
Open Tender
Electrical Works
Percentage
60 days
Executive Engineer PWD Electrical Div. Ist Jodhpur
Please refer Tender documents
3 documents required · 3 mandatory
₹500
Secretary, RREIS Executive Engineer PWD Electrica
₹3,120
Yes
Executive Engineer PWD Electrical Div. Ist Jodhpur
18 Sept 2026
18 Sept 2026
29 Sept 2026
18 Sept 2026
28 Sept 2026
18 Sept 2026
24 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 with 7 mil Glass Cloth and 3 coats of anti UV paint (on area which is exposed to weather) including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. | - | - | - | - |
| 2 | 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 5 | mtr | 842.52 | ₹4,212.6 |
| 3 | 9.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | 5 | mtr | 604.16 | ₹3,020.8 |
| 4 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. | - | - | - | - |
| 5 | 20 mm | 10 | mtr | 154.58 | ₹1,545.8 |
| 6 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia | - | - | - | - |
| 7 | 50 mm dia per running inch length | 40 | per inch | 79.06 | ₹3,162.4 |
| 8 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. | 2 | Each | 639.56 | ₹1,279.12 |
| 9 | Supply , Installation, Testing and Commissioning of Inverter type Air cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low &high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity up to 42 Degree Celsius ambient temperature. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 degree C (out door ambient temperature) | - | - | - | - |
| 10 | Cooling capacity 6800-7000 Watt, ISEER not less then 3.8 | 2 | Each | 64,802.06 | ₹1,29,604.12 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tendernotice_2.pdf
PDF • 20.12 MB
Tendernotice_3.pdf
PDF • 0.79 MB
Tendernotice_4.pdf
PDF • 1.92 MB
Tendernotice_5.pdf
PDF • 0.48 MB
Tendernotice_6.pdf
PDF • 0.36 MB
Tendernotice_7.pdf
PDF • 0.11 MB
BOQ_1061273.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .