Repairs to Govt. Children Home at Amreli, Dist. Amreli. (Providing Fire Fighting System) (Institutional Bldg Less than 15M in height with plot area more than 1000 Sqm.)
333567
10 of 2026-27
Open
Civil Works - Buildings
Works
Amreli
7 documents required · 7 mandatory
₹2,400
Executive Engineer, R and B Division, Amreli
₹61,000
11 Aug 2026
11 Aug 2026
11 Aug 2026
21 Aug 2026
11 Aug 2026
120 days
Name of Work :- Repairs to Govt. Children Home at Amreli, Dist : Amreli. ( Providing Fire Fighting
System. ) ( Institutional Bldg Less than 15M in height with plot area more than
BILL OF QUANTITIES
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
1 1.00 Supplying,Installation,Testing and Commissioning of 609787.50 Set
Diesel Engine Driven stand by PUMP suitable for Fire
Fighting system,with base frame for pump also Back
pull out,Horizontal,Centrifugal endSuction type pump
as per IS:1520 complete having cast iron casting, alloy
bronze impellers and difusers, Pump shall be directly
coupled to 2900 RPM 415 V 50 cys. AC 3 phase
TEFC squirrel cage motor, Centrifugal 2280 LPM@
70 Meter Head LPM from all causes including
pressure guages, exhaust piping with silencer,Battery
of approved make with Battery charger with
connection wire & accessories with volt meter, Neon
Led, Push button, Lock and key, Fuel level indicator,
RPM meter, Battery stand, Charger mounting,coupling
guard etc.Complete as directed.
2 1.00 Providing and Fixing FIRE JOKEY PUMP for fire 120796.00 Set
system having single outlet diffuser horizontal type
centrifugal pump of capacity 180 LPM at 70 Mt. head
with 2900 RPM Motor including all accessories. cast
iron casting, alloy bronze impellers and difusers,
150mm outlet, 3 phase, fixing with necessary
accessories, materials, transportation, labour etc. as
directed by Engineer-in-Charge.
3 2.00 Supply Installing Testing & Commissioning of 22068.50 No.
150mm Dia Number C.I. Heavy Duty FOOT VALVE
With Flange, Nut-Bolts, GasketEtc. necessary
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
4 163.00 Supply Installing Testing & Commissioning of 150 3554.19 Mtr
Dia. G.I. Pipe Class C, ISI Marked, Supply Fabrication
( Including civil work like making hole, soil remove
etc.) Installation, painting, Fitting ( i.e Elbows, Tee,
Reducer Coupling Flanges, Nipple etc.) with proper
supports including structural and civil costructed, Nut,
Bolt and washer, Gasket, Fabricated piping with fitting
must be Tested for any leakage and Hydraulically
tested at 15kg/sqcm and it must be satisfied and
certified by Engineer in charge.
5 26.00 Supply Installing Testing & Commissioning of 100 3136.05 Mtr
Dia. G.I. Pipe Class C, ISI Marked, Supply Fabrication
( Including civil work like making hole, soil remove
etc.) Installation, painting, Fitting ( i.e Elbows, Tee,
Reducer Coupling Flanges, Nipple etc.) with proper
supports including structural and civil costructed, Nut,
Bolt and washer, Gasket, Fabricated piping with fitting
must be Tested for any leakage and Hydraulically
tested at 15kg/sqcm and it must be satisfied and
certified by Engineer in charge.
6 546.00 Supply Installing Testing & Commissioning of 50 NB 1777.10 Mtr
G.I. Pipe Class C, ISI Marked, Supply Fabrication (
Including civil work like making hole, soil remove
etc.) Installation, painting, Fitting ( i.e Elbows, Tee,
Reducer Coupling Flanges, Nipple etc.) with proper
supports including structural and civil costructed, Nut,
Bolt and washer, Gasket, Fabricated piping with fitting
must be Tested for any leakage and Hydraulically
tested at 15kg/sqcm and it must be satisfied and
certified by Engineer in charge.
7 186.00 Supply Installing Testing & Commissioning of 25 NB 731.75 Mtr
G.I. Pipe Class C, ISI Marked, Supply Fabrication (
Including civil work like making hole, soil remove
etc.) Installation, painting, Fitting ( i.e Elbows, Tee,
Reducer Coupling Flanges, Nipple etc.) with proper
supports including structural and civil costructed, Nut,
Bolt and washer, Gasket, Fabricated piping with fitting
must be Tested for any leakage and Hydraulically
tested at 15kg/sqcm and it must be satisfied and
certified by Engineer in charge.
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
8 248.00 Supply Installing Testing & Commissioning of SS 551.71 No.
SPRINKLER suitable for 25mm dia MS pipe
including necessary stainless steel spindal, Gasket, Nut
Bolts, etc. necessary complete.
9 2.00 Supply Installing Testing & Commissioning of 5226.75 No.
100mm Dia Double Flanged ISI-Mark C.I Sluice /
Butterfly Valve with gun metal / SS working
part,stainless steel spindal, Gasket, Nut Bolts, etc.
necessary complete.
10 2.00 Supply Installing Testing & Commissioning of 11673.08 No.
100mm Dia Double Flanged ISI-Mark C.I Non-Return
Valve with Gasket, Nut- Bolts, etc necessary
11 2.00 Supply Installing Testing & Commissioning of 8014.35 No.
150mm Dia Double Flanged ISI-Mark C.I Sluice
Valve with Gasket, NutBolts, etc. necessary complete.
12 2.00 Supply Installing Testing Commissioning of 150mm 20035.88 No.
Dia Double Flanged ISI-Mark C.I Non-Return Valve
with Gasket,Nut Bolts, etc .necessary complete.
13 2.00 Supply Installing Testing & Commissioning of 26888.73 No.
150mm Dia ISI-Mark C.I Non-Return Valve with
gun metal / SS working part,stainless steel spindal,
Gasket, Nut Bolts, etc. necessary complete.
14 2.00 Supply Installing Testing & Commissioning of 11673.08 No.
100mm Dia ISI-Mark C.I Non-Return Valve with
gun metal / SS working part,stainless steel spindal,
Gasket, Nut Bolts, etc. necessary complete.
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
15 1.00 Supply Installing Testing Commissioning of 150mm 22358.88 No.
dia "Y" Type Stainer ISI-Mark with Gasket,Nut Bolts,
etc .necessary complete.
16 1.00 Supply Installing Testing Commissioning of 100mm 15157.58 No.
dia "Y" Type Stainer ISI-Mark with Gasket,Nut Bolts,
etc .necessary complete.
17 16.00 Supply Installing Testing & Commissioning of 1858.40 No.
25mm Dia ISI-Mark C.I Ball Valve with gun metal /
SS working part,stainless steel spindal, Gasket, Nut
Bolts, etc. necessary complete.
18 2.00 25mm Dia Air Valve for Riseing Main Line. For 2555.30 No.
Air Release Including supply, Installing, Testing And
Commissioning etc. complete.
19 2.00 Supply Installing Testing & Commissioning of 1916.48 No.
Pressure Guage 100mm Dia. 1 % Accuracy Direct
Bottom 3/8” BSP connection In Brass Socket &
Range 0 to 16 Kg/Cm2 etc necessary
20 8.00 Supplying, Installing, testing & Commissioning of 6910.93 No.
63mm SS Single control type HYDRANT VALVE as
per IS: 5290 with ISI marked 75 mm inlet and 63mm
female instantaneous coupling, rubber washer, flange,
Gasket nut-bolts and cast iron hand wheel operation
with close and open direction as directed.
21 8.00 Supply Installing Testing & Commissioning of 2381.08 No.
63mm S.S. BRANCH PIPE / SHORT BRANCH ( ISI
Marked ) of standard length with 20mm bore
hexagonal nozzle as per IS:903 with necessary joints
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
22 8.00 Supply Installing Testing & Commissioning of 5981.73 No.
Hose CABINET made out ouf M.S. sheet to
accommodate 1 sets of hose of 15 Mtr. length Hose
Pipe &1 No. of Branch Pipe with Nozzle, with
necessary fabrication support and joints and hinged
door with 3mm glass and lock including painted to
scarlet red colour & mounted to wall with proper
stand/hanger etc complete.
23 8.00 Providing and fixing 63mm Pyroline FIRE HOSE of 8362.80 No.
approved brand conforming to IS: 636 Type B having
crushing pressure of 37.20 kg/cm2 of ISI marked of
mtr length fitting with necessary S.S 63mm delivery
hose coupling as IS: 903 with ISI mark binded with
copper wire etc complete directed.
24 2.00 Supply Installing Testing & Commissioning of 10453.50 No.
63mm Dia C. I. FOUR WAY FIRE BRIDGE Inlet
Valve with Gun-Metal Non-Return, Flange, Gasket,
Nut-Bolts, etc. Complete.
25 4.00 Providing and fixing FIRST AID HOSE REEL wall 9408.15 No.
mounting fix type having side of the hose reel made of
MS , providing with 30mtr long 25mm dia PVC nylon
braided flexible hose with S.S shut off nozzle of
approved quality etc complete as directed.
26 88.80 Excavation for foundation upto 1.5 m depth including 268.92 Cum
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter
lead.(C) Hard Murrum
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
27 2.00 Construction of brick masonry Valve Chamber with 2932.93 No.
brick having crushing strength not less than
Kg/Cm2 in C.M. 1:5.and M. S. cover having 2mm
th.sheet and frame of MS angle with
hinges,handle,locking arrangement and Painting and
R.C.C top slab with 1:2:4 mix( 1- cement : 2 -coarse
sand:4 -graded stone aggregate 20 mm size )
foundation concrete 1:5:10 inside plaster 15 mm thick
with cement mortar 1:3 finished smooth with a floating
coat of neat cement on walls and bed concrete etc.
(A) inside dimensions 455 mm x 610 mm
28 24.00 Supplying and Fixing 4.5 Kg Fire Extinguisher, CO2 8362.80 No.
Gas as per IS 15222 / ISI 15683 for fire classes BC &
Electrical Fire, Discharge Control mechanism fitted
with high pressure steel braided Discharge Hose and
Flat Horn with diffuser Nozzles for dispersed
discharge of CO2, internal coating not applicable &
external coating of enamel spray painting, Cylinders
construction: hot spinning seamless & bearing ISI
mark, confirm to IS 7285 and approved by EIC. Fire
Class 21B rating as per IS 15683 and ISI Mark.
29 24.00 Supplying and Fixing Fire Extinguisher as per IS : 7549.75 No.
15683 with ISI Marked, Type : ABC, Capacity : 06 kg,
Fire Rating : 4A, Stored Pressure Type, Filled with
50% Mono Ammonium Phosphate based multi
purpose Dry Powder suitable for Class A, B & C Fire,
Pressurized by Dry Nitrogen, Complete with all
respect with stand/wall mounting bracket
30 2.00 Supplying and Fixing Modular Wall Mounted ( with 12544.20 No.
brackets ) portable Clean Agent HFC-236fa 5 Kg gas
based Fire Extinguisher which leaves no residure
making it safe for use on sensitive equipment
Extinguisher performance tested by NABL accredited
Lab, MSDS of the Extinguishing agent is a must
current and valid BIS certification 15683 2006, EN
approved ISI and GE approved / Marked. LPCB
approved, EN:ISO:9001 & ISO 10002:2004 certified
with 3 years warranty ) ( in / near Electrical Panel
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
31 8.00 Providing of FIRE BUCKET WITH STAND which 10453.50 No.
icludes a set of 4 nos buckets with Capacity 09Ltr and
a stand , G.I.24 Gauge, Painted Red & Marked
“FIRE” as directed.
32 2.00 Supplying, Installing, Testing and commissioning of 346610.89 No.
10 Zone FIRE ALARM CONVENTIONAL PANEL
central processing unit with at all the Two floor with
high intensity Hooter and manual call point with
hammer with the following loop modules and capable
of supporting minimum 120 detectors per loop and
length up to 1.10 km. Alarm panel contains Zone wise
Fire Fault LED indication, Zone isolation facility,
mains on system On, Charge on Visual indications.
Auto Dialer attached facility, External switch for reset,
silence, Lamptest, External Switch to test each zone
fire, open - short status manually, inbuilt Buzzer,
inbuilt battery charger & battery spaces. Operates on
230v AC, 50 HZ AC supply Fire alarm panel with
resettable 02 nos of manual call point for use in case of
emergency for activate the fire alarm system connected
with 3 nos sounders and 125 nos of smoke detectors
with base to address emergency.
33 2.00 On/Off switch with pipe & 3c x 1 sq mm cable wiring 3850.23 No.
34 4.00 Providing & Fixing of Retroreflective High intensity 1638.46 No.
grade on Acrylic plate of size 450mm 150mm made of
3 mm thick Acrylic name plate with lettering using
High intensity grade retro reflctive letters, incl. fixing
on each chamber as directed & Instructed by Engineer-
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
35 1200.00 Supplying and Fixing of MARKING STRIPS are 6.97 Sq.Cm
broadly used on the roads, parking lots and many more
places by manufacturer / dealer to help/provide the
right directions to the people in making fast and
immediate movement from the hazardous places.
Marking strips for stairs & walls : 120 x 5.7 cm size.
These strips are designed with the help of premium
quality basic material. It should have water proof, Tear
resistance, precisely designed, made of : Photo
luminescent rig-id plastic, 2 mm thickness, printed on
high quality gloss paint with UV resistance, Material
used : Non-Radioactive, non-phosphorous, non-toxic
and lead free, Time after removing the light source:
minutes, Luminescent intensity : 30 med/sqm,
Luminescent intensity greater than 0.32 mcd/sqm,
period of light decay : 3100 minutes with 5 years
36 162.00 Supply, laying, testing & commissioning 1.1 kV grade, 145.44 Mtr
XLPE insulated, stranded Aluminium conductor,
galvanised steel flat strip / round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (to
be laid on wall surface with necessary clamps / in
existing cable trench / cable trays / conduit / pipe
sleeves at road crossing or floor as per site
requirement) conforming to IS:7098 (Part-1) &
IEC:60502 (Part-1) of following sizes: (g) 3 Core x
37 2.00 Supplying & Installation PRESSURE GUAGE of 150 2903.75 No.
mm dia. 0-21 Kg/cm2 fitted with 12/15 mm dia pad
cock valve and G.I. elbow etc. complete as required.
38 162.00 Providing and erecting IPVC insulated flat 124.23 Mtr
submersible cable as per detailed technical
specifications of R/C of GWSSB conforming to IS
39 1.00 Lowering / Lifting of 3 phase submersible pump set 1818.00 Job
with HDPE pipe and cable into bore well with
necessary fitting accessories by means of mechanised
derrick / chain pulley / fixtures and jointing the cable
with fuse unit / control panel board including
satisfactory testing. (A) Up to 90 meters depth
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
40 1.00 Supplying & erecting approved make motor 13557.23 Job
CONTROL CUBICAL PANEL DOL / Star Delta
starter suitable for local & remote pump control
application consisting of MPCB, overload relay and
contactors as per Type II coordination including digital
voltmeter, analogue ammeter with selector switch, run
hour meter, required protective relays & control
accessories. [C] D.O.L. up to 7.50 HP including
Providing dust and vermin proof MS cabin having two
compartments, one for panel board and other for
energy meter and fuse unit with required locking
arrangement , minimum degree of protection IP 52 as
per IS 2147 fabricated from CRCA sheer steel
minimum thickness for base frame / channel / gland
plates for 3 mm for load bearing members,1.6 mm for
ineternal members of size 0600m x 0.70 m x 040 m
41 10000.00 Providing erecting and fixing tripple coated PVC 10.12 Litre
WATER TANK of required capacity each including
necessary transportation to the site, making plateform
with matching flooring to the terrace, fixing fitting and
connecting to inlet and outlet with all necessary
fittings & connection complete on terrace.
42 2.00 Providing & Fixing emergency EVACAUTION Plan 34845.00 No.
by manufacturer / dealers helps the people in making
in making fast and immediate movement from the
hazardous places. A team of skilled professionals who
design thisplan while keeping aal the safety factors in
mind. It should have precisely designed. Clarity, Easy
to understand outer Cover, 2 mm thick photo
luminescent plastic, paint, Highest quality UV resistant
glass paint, Frame aluminium made, material non-
radioactive, non-phosphorous, non toxic and lead free,
brushed stainless steel, transparent acrylic glass,
opaque acrylic glass 450 x 350 mm Glowing Time :
3100 minutes, Luminance 215 mcd/sq with 5 years
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
43 403.00 Providing and fixing M.S. Grill with alround framing 1041.36 SQM
using 25x25x3 mm M.S. hollow pipe including two
numbers of horizontal supports including 2 coats of
oil painting with good quality G.I. Mosquito Net fixed
using screw & M.S. flat 25x3mm strained and fixed to
window with G.I.staples including fixing Jali / grill
with RCC column / Wall in true line and level
including cost of cutting of G.I.pipe and chain link,
welding charges etc.complete.
44 229.00 Removing, Repairing and Re-fixing M.S.Window or 437.53 SQM
Alluminium slinding windows incl providing and
fixing missing members or hardware as required and
incl providing and fixing necessary fitting like hinges,
stopper, handle, supports, rollers, m.s. member and
sealling all the outer edges of the window with
approved colour silicon sealant from both side to
prevent the wall incl. all material, machine, tools,
labour etc. complete as directed by Engineer-In-
45 44.00 Excavation for foundation for depth from 1.5 m to 287.21 Cum
3.0 m including sorting out and stacking of useful
materials and disposing off the excavated stuff
upto 50 Meter lead. (C) Hard Murrum
46 11.20 Providing and laying cement concrete 1:3:6 (1- 3095.25 Cum
Cement : 3- coarse sand : 6- hand broken stone
aggregates 40 mmnominal size) and curing complete
excluding cost of formwork in (A) Foundation and
47 18.30 Brick work using common burnt Clay building bricks 4214.33 Cum
having crushing strength not less than 35 kg / sq.cm in
foundation and plinth in Cement mortar 1:6 (1 Cement
: 6 fine sand) (A) Conventional
48 9.80 Providing and laying cement concrete 1:2:4 (1 Cement 3805.29 Cum
: 2 corse sand : 4 granded stone aggregate 20mm
nominal size) and curing complete including cost of
form work in (a) Foundation and Plinth
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
49 7.50 Filling in plinth with sand under floors 481.80 Cum
includingwatering ramming, consolidating and
dressing etc.complete.
50 27.49 Providing and laying controlled cement concrete M- 5844.80 Cum
250 and curing complete incl. the cost of formwork but
excluding reinforcement for reinforced concrete work
in Walls from top of foundation level For Ground
51 8.40 Providing and laying controlled cement concrete M- 6684.16 Cum
200 and curing complete including the cost of
formwork but excluding reinforcement for reinforced
concrete work in- Slabs For Ground Floor Slab.
52 23.00 20 mm thick sand faced Mala cement plaster on wall 342.41 Sqm
upto height 10 mts.above ground level consisting of
mm thick backing coat of C.M 1:3 (1 cement : 3 sand
)and 8 mm thick finishing coat of C.M 1 : 1(1 cement :
1 Sand) etc. complete.
53 4023.00 Providing TMT Bar FE 500D steel reinforcement for 77.29 Kg
R.C.C. work including bending, binding and placing in
position complete upto floor two level. For Ground
54 4.02 Providing and applying anticarrasive treatment with 4168.96 MT
polymer base materials to the steel rainfarcement
including descaling the dust and applying the
preventive coating of approved make (for the R.C.C.
structures near coastal area only) etc complete.
55 40.80 Providing and laying Ceramic tiles 6mm thick in 992.15 Sqm
flooring treads of steps and landing laid on a bed of
12mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) finishing with flush pointing in white cement. .
56 88.70 Providing and laying coloured glazed tiles of the size 1488.24 Sqm
mm in skirting, risers of steps and dedo on 10 mm.
thick cement plaster 1:3 (1 cement : 3 coarse sand) &
jointed with white cement slurry.
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
57 23.00 Finishing wall with weather proof exterior emulsion 120.26 Sqm
paint on wall surface(two coats) to give an required
shape even shade after thoroughly brushing the surface
to rempve all dirt, and remains of loose powdered
materials etc complete.
58 4.00 Providing and fixing C.I. Manhole cover 0.60mm x 958.17 Nos
0.45mm size having weight not less than 35Kg.
59 16.00 Providing and fixing cast iron steps of size 500mm x 151.50 Nos
150mm x 22.5mm and painting with two coats of Anti-
corrosive paint etc. complete.
60 9.00 Providing laying and jointing in true line and level 72.65 Rmt
15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp
at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
61 40.00 Providing laying and jointing in true line and level 91.84 Rmt
25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp
at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
" I / We Am / Are willing to carry out the work @ __________ % @
(should be written in Figures and Words) of the estimated rates mentioned above, Amount of
My / Our tender works out as under :-
Estimated Amount Put to tender. Estimated Amount Put to tender.
Add. _______ % Above Rs. ____________ Deduct _______ % Below Rs. __________
In Words In Words
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be more In Figures In words according to
or less. estimated
1 All work shall be carried out as per P.W.D. Hand Book and other specification of the Division or as directed.
2 Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold good for work under all conditions, site moisture,
3 The contractor shall exhibit the details of work, tender amount, specifications as per Govt. circular No. BDG / 3277 / 1657 Dated. 26-4-1978 and G.R. No.
TNC/ 1090-24 C, Dated. 18-11-91 as directed by the Engineer-in-charge on the work site for which contractor
4 Testing of materials as per statement attached with the specifications. The materials shall be tested in G.E.R.I. Bill for testing shall be paid by the department
and 1 % (One percentage) of amount put to tender after deduction the cost of cement & steel mentioned in clause 59(a)
5 In R.C.C. item where there is change of grade mix or change as per actual mix design the difference of of cement consumption shall be added / deducted from
rate of original item at the rate mentioned in tender.
6 For earthquake resistance provision the works shall be carried cut as per the instruction of Engineer in charge.
7 The other conditions of Schedule "B" will remain unchanged.
8 Labor Cess 1 % (One Percent) of Bill Amount shall be recovered from contractor of building or other construction works. (Resolution of Employment and
condition Act 1996)
Signature of Contractor Executive Engineer
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
GR.pdf
Performance Bond and Bitumen date.pdf
SBD BOOK.pdf
SCH B.pdf
NOTE OF SCH B.pdf
Bank Credit CertI. as per clause 4.5.6 of SBD.pdf
FIRE CONDITION.pdf
SPECIFICATION INDEX.pdf
SPECIFICATION.pdf
TEST SCH.pdf
TN No.10 of 2026-27.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .