Executive Engineer
Executive Engineer Mechanical Division
Providing Installation and Commissioning of High Wall Split Window Cassette Floor mounted Split type Air Conditioning System as and when urgently required in different buildings of IGM Hospital Agartala for a period of 01 year during the year 202627
2026_CEPWD_73469_1
30_EE_DNIT_MECHDIVN_AGT_202627
Open Tender
Electrical Works
365 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹38,920
4 Jun 2026
4 Jun 2026
15 Jun 2026
4 Jun 2026
15 Jun 2026
4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermatically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS1391(part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 HZ, single phase AC supply capable of performing a)cooling b)dehumidifying c)air circulating d)filtering having rated cooling capacity | ||||||
| 1.01 | 1.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 3000 Kcal/hr or 12000 BThu/hr or 3500 watt). | 1 | No | - | - | Item19 |
| 1.02 | 1.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be less than 4500 Kcal/hr or 18000 Bthu/hr or 5250 watt) | 5 | Nos | - | - | Item19 |
| 1.03 | 2.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be less than 6000 Kcal/hr or 24000 Bthu/hr or 7000 watt) | 14 | Nos | - | - | Item19 |
| 1.04 | 1.5 TR window type AC machine (Minimum rated cooling capacity should not be less than 4500 Kcal/hr or 18000 Bthu/hr or 5250 watt) | 2 | Nos | - | - | Item19 |
| 2Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) ceiling mounted Cassette/Floor mounted vertical split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermatically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS1391(part-II) specification (Except power consumption) suitable for operation on 420 volt, 50 HZ, single phase AC supply capable of performing a)cooling b)dehumidifying c)air circulating d)filtering having rated cooling capacity | ||||||
| 2.01 | 3.0 TR Cassette type AC machine (Minimum rated cooling capacity should not be less than 9000 Kcal/hr or 36000 Bthu/hr or 10500 watt) | 1 | No | - | - | Item19 |
| 2.02 | 3.65 TR floor mounted vertical split type AC machine (Minimum rated cooling capacity should not be less than 10950 Kcal/hr or 43800 Bthu/hr or 12775 watt) | 4 | Nos | - | - | Item19 |
| 3 | Standard installation, testing and commissioning of 1.0/1.5 / 2.0 TR high wall split type / window AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge. | 22 | Nos | - | - | Item19 |
| 4 | Standard installation, testing and commissioning of 3.0 TR ceiling mounted cassette type AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge. | 1 | No | - | - | Item19 |