Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53,283.41Accepted-AOC | L1 | Accepted-AOC Work awarded | |
| 2 | L2₹59,848.92+₹6,565.51 (12.3%)Rejected-AOC | L2 | Rejected-AOC higher rate hence rejected |
Tender Value
₹64,354
EMD Value
₹1,609
Closing Date
27 Sept 2024, 5:00 pmClosed
Assistant Engineer
Assistant Engineer, LID and EW Section Pattuvam GP Ariyil P O PIN 670143 kannur dist
GENERAL-Pattuvam GP - Pro No.99/25 - Three Phase Wiring for MCF-conversion- General Electrical Work
2024_LSGD_691249_6
1/2024/AE/LIDandEW/PTVM
Open Tender
Civil Works - Buildings
Item Rate
180 days
pattuvam gp
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹1,609
Yes
5 Nov 2024
17 Sept 2024
30 Sept 2024
17 Sept 2024
27 Sept 2024
17 Sept 2024
Amount
General Wiring
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD87265/2024-2025:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD87267/2024-2025:Supplying and fixing 40 amps rating, 240/415 volts, "C" curve FP-MCB, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD87539/2024-2025:Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD87277/2024-2025:Supply and providing the following 25 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
OD87288/2024-2025:Supplying and fixing 63A, HRC Fuse with HRC Fuse Link with connections, in existing meter board
OD87289/2024-2025:Supplying and fixing 63A, 2way Neutral Link mounted on DMC/SMC base with connections, in existing meter board
OD87307/2024-2025:Supply and providing 5 Kg. ABC type Fire Extinguisher with hose and clamps including fixing it to wall as required.
OD87313/2024-2025:Supply and providing 2.0mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.
OD87314/2024-2025:Supply and Fixing Danger 415 V, 150 X 100 mm Enameled danger plates.
OD87528/2024-2025:Charges for preparation of electrical scheme/drawing and submissio of test and completion report to KSEB excluding CD charges. (for single phase)
RAMAKRISHNAN P
Bidder Name
Siju C K
RAMAKRISHNAN P
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1076098.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .